Heenam Yoon

Dr. Heenam Yoon

Department of Human-Centered Artificial Intelligence, Sangmyung University, Seoul, Korea
orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 June 2017 in Sensors
Verified
Journal Article
Open access
PDF file
JHJeong Heo
Jeong Heo
HYHeenam Yoon
Heenam Yoon
KPKwang Suk Park
Kwang Suk Park
Amyotrophic lateral sclerosis (ALS) patients whose voluntary muscles are paralyzed commonly communicate with the outside world using eye movement. There have been many efforts to support this method of communication by tracking or detecting eye movement. An electrooculogram (EOG), an electro-physiological signal, is generated by eye movements and can be measured with electrodes placed around the eye. In this study, we proposed a new practical electrode position on the forehead to measure EOG signals, and we developed a wearable forehead EOG measurement system for use in Human Computer/Machine interfaces (HCIs/HMIs). Four electrodes, including the ground electrode, were placed on the forehead. The two channels were arranged vertically and horizontally, sharing a positive electrode. Additionally, a real-time eye movement classification algorithm was developed based on the characteristics of the forehead EOG. Three applications were employed to evaluate the proposed system: a virtual keyboard using a modified Bremen BCI speller and an automatic sequential row-column scanner, and a drivable power wheelchair. The mean typing speeds of the modified Bremen brain–computer interface (BCI) speller and automatic row-column scanner were 10.81 and 7.74 letters per minute, and the mean classification accuracies were 91.25% and 95.12%, respectively. In the power wheelchair demonstration, the user drove the wheelchair through an 8-shape course without collision with obstacles.

13 April 2021 in IEEE Journal of Biomedical and Health Informatics
Verified
Journal Article
Closed access
HKHyun Bin Kwon
Hyun Bin Kwon
SCSang Ho Choi
Sang Ho Choi
DLDongseok Lee
Dongseok Lee
Dongyeon SonDongyeon Son
Dongyeon Son
HYHeenam Yoon
Heenam Yoon
KPKwang Suk Park
Kwang Suk Park
Manual scoring of sleep stages from polysomnography (PSG) records is essential to understand the sleep quality and architecture. Since the PSG requires specialized personnel, a lab environment, and uncomfortable sensors, non-contact sleep staging methods based on machine learning techniques have been investigated over the past years. In this study, we propose an attention-based bidirectional long short-term memory (Attention Bi-LSTM) model for automatic sleep stage scoring using an impulse-radio ultra-wideband (IR-UWB) radar which can remotely detect vital signs. Sixty-five young (30.0 ± 8.6 yrs.) and healthy volunteers underwent nocturnal PSG and IR-UWB radar measurement simultaneously; From 51 recordings, 26 were used for training, 8 for validation, and 17 for testing. Sixteen features including movement-, respiration-, and heart rate variability-related indices were extracted from the raw IR-UWB signals in each 30-s epoch. Sleep stage classification performances of Attention Bi-LSTM model with optimized hyperparameters were evaluated and compared with those of conventional LSTM networks for same test dataset. In the results, we achieved an accuracy of 82.6 ± 6.7% and a Cohen's kappa coefficient of 0.73 ± 0.11 in the classification of wake stage, REM sleep, light (N1+N2) sleep, and deep (N3) sleep which is significantly higher than the conventional LSTM networks (p < 0.01). Moreover, the classification performances were higher than those reported in comparative studies, demonstrating the effectiveness of the attention mechanism coupled with bi-LSTM networks for the sleep staging using cardiorespiratory signals.

7 July 2023 in Biomedical Engineering Letters
Verified
Journal Article
Closed access
PDF file
HYHeenam Yoon
Heenam Yoon
SCSang Ho Choi
Sang Ho Choi

14 May 2015 in Sensors
Verified
Journal Article
Open access
PDF file
HLHong Ji Lee
Hong Ji Lee
SHSu Hwan Hwang
Su Hwan Hwang
HYHeenam Yoon
Heenam Yoon
WLWon Kyu Lee
Won Kyu Lee
KPKwang Suk Park
Kwang Suk Park
In this study, we developed and tested a capacitively coupled electrocardiogram (ECG) measurement system using conductive textiles on a bed, for long-term healthcare monitoring. The system, which was designed to measure ECG in a bed with no constraints of sleep position and posture, included a foam layer to increase the contact region with the curvature of the body and a cover to ensure durability and easy installation. Nine healthy subjects participated in the experiment during polysomnography (PSG), and the heart rate (HR) coverage and heart rate variability (HRV) parameters were analyzed to evaluate the system. The experimental results showed that the mean of R-peak coverage was 98.0% (95.5%–99.7%), and the normalized errors of HRV time and spectral measures between the Ag/AgCl system and our system ranged from 0.15% to 4.20%. The root mean square errors for inter-beat (RR) intervals and HR were 1.36 ms and 0.09 bpm, respectively. We also showed the potential of our developed system for rapid eye movement (REM) sleep and wake detection as well as for recording of abnormal states.

19 March 2016 in Sensors
Verified
Journal Article
Open access
PDF file
WLWon Kyu Lee
Won Kyu Lee
HYHeenam Yoon
Heenam Yoon
CHChungmin Han
Chungmin Han
KJKwang Min Joo
Kwang Min Joo
KPKwang Suk Park
Kwang Suk Park
Ballistocardiographs (BCGs), which record the mechanical activity of the heart, have been a subject of interest for several years because of their advantages in providing unobtrusive physiological measurements. BCGs could also be useful for monitoring the biological signals of infants without the need for physical confinement. In this study, we describe a physiological signal monitoring bed based on load cells and assess an algorithm to extract the heart rate and breathing rate from the measured load-cell signals. Four infants participated in a total of 13 experiments. As a reference signal, electrocardiogram and respiration signals were simultaneously measured using a commercial device. The proposed automatic algorithm then selected the optimal sensor from which to estimate the heartbeat and respiration information. The results from the load-cell sensor signals were compared with those of the reference signals, and the heartbeat and respiration information were found to have average performance errors of 2.55% and 2.66%, respectively. The experimental results verify the positive feasibility of BCG-based measurements in infants.

19 May 2021 in IEEE Access
Verified
Journal Article
Open access
HKHyun Bin Kwon
Hyun Bin Kwon
Dongyeon SonDongyeon Son
Dongyeon Son
DLDongseok Lee
Dongseok Lee
HYHeenam Yoon
Heenam Yoon
MLMi Hyun Lee
Mi Hyun Lee
KPKwang Suk Park
Kwang Suk Park
Polysomnography (PSG) is the gold-standard for sleep apnea and hypopnea syndrome (SAHS) diagnosis. Because the PSG system is not suitable for long-term continuous use owing to the high cost and discomfort caused by attached multi-channel sensors, alternative methods using a non-contact sensor have been investigated. However, the existing methods have limitations in that the radar-person distance is fixed, and the detected apnea hypopnea (AH) event cannot be provided in real-time. In this paper, therefore, we propose a novel approach for real-time AH event detection with impulse-radio ultra-wideband (IR-UWB) radar using a deep learning model. 36 PSG recordings and simultaneously measured IR-UWB radar data were used in the experiments. After the clutter was removed, IR-UWB radar images were segmented by sliding a 20-s window at 1-s shift, and categorized into two classes: AH and N. A hybrid model combining the convolutional neural networks and long short-term memory networks was trained with the data, which consisted of class-balanced segments. Time sequenced classified outputs were then fed to an event detector to identify valid AH events. Therefore, the proposed method showed a Cohen’s kappa coefficient of 0.728, sensitivity of 0.781, specificity of 0.956, and an accuracy of 0.930. According to the apnea-hypopnea index (AHI) estimation analysis, the Pearson’s correlation coefficient between the estimated AHI and reference AHI was 0.97. In addition, the average accuracy and kappa of SAHS diagnosis was 0.98 and 0.96, respectively, for AHI cutoffs of ≥ 5, 15, and 30 events/h. The proposed method achieved the state-of-the-art performance for classifying SAHS severity without any hand-engineered feature regardless of the user’s location. Our approach can be utilized for a cost-effective and reliable SAHS monitoring system in a home environment.