Non-intrusive electrocardiogram (ECG) monitoring has many advantages: easy to measure and apply in daily life. However, motion noise in the measured signal is the major problem of non-intrusive measurement. This paper proposes a method to reduce the noise and to detect the R peaks of ECG in a stable manner in a sitting arrangement using non-intrusive sensors. The method utilizes two capacitive ECG sensors (cECGs) to measure ECG, and another two cECGs located adjacent to the sensors for ECG are added to obtain the information on motion. Then, active noise cancellation technique and the motion information are used to reduce motion noise. To verify the proposed method, ECG was measured indoors and during driving, and the accuracy of the detected R peaks was compared. After applying the method, the sum of sensitivity and positive predictivity increased 8.39% on average and 26.26% maximally in the data. Based on the results, it was confirmed that the motion noise was reduced and that more reliable R peak positions could be obtained by the proposed method. The robustness of the new ECG measurement method will elicit benefits to various health care systems that require noninvasive heart rate or heart rate variability measurements.
This paper proposes a prefiltered observation-based affine projection algorithm (APA) to achieve robustness against outliers. The conventional robust algorithm for correlated input signal, which is called the affine projection sign algorithm (APSA), was developed by using the $\mathcal{L}_1$ -norm of the error signal. However, it suffers from slow tracking speed for a system change suddenly, because it can not distinguish between the time-varying system and occurrence of the impulsive noise. To overcome this problem, the proposed algorithm is induced from the matrix inequalities in no impulsive interference. The proposed algorithm determines the necessity for updating the weight vector in the noise. Hence, it has robustness and tracking ability because it discriminates between the time-varying system and occurrence of the impulsive noise. Simulations in a system identification scenario show that the proposed algorithm surpasses the APA and APSA in terms of convergence rate and tracking performance under the impulsive noise environment.
14 May 2019 in Circuits, Systems, and Signal Processing
Support vector machines (SVMs) utilize hyper-parameters for classification. Model selection (MS) is an essential step in the construction of the SVM classifier as it involves the identification of the appropriate parameters. Several selection criteria have been proposed for MS, but their usefulness is limited for physiological data exhibiting inter-subject variance (ISV) that makes different characteristics between training and test data. To identify an effective solution for the constraint, this study considered a leave-one-subject-out cross validation-based selection criterion (LSSC) with six well-known selection criteria and compared their effectiveness. Nine classification problems were examined for the comparison, and the MS results of each selection criterion were obtained and analyzed. The results showed that the SVM model selected by the LSSC yielded the highest average classification accuracy among all selection criteria in the nine problems. The average accuracy was 2.96% higher than that obtained with the conventional K-fold cross validation-based selection criterion. In addition, the advantage of the LSSC was more evident for data with larger ISV. Thus, the results of this study can help optimize SVM classifiers for physiological data and are expected to be useful for the analysis of physiological data to develop various medical decision systems.