Minho Choi

Dr. Minho Choi

POSTECH
orcid

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 December 2017 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
MCMinho Choi
Minho Choi
GKGyogwon Koo
Gyogwon Koo
MSMinseok Seo
Minseok Seo
SKSang Woo Kim
Sang Woo Kim
This paper proposes a wearable device-based system to monitor the abnormal conditions of a driver, including stress, fatigue, and drowsiness. The system measures the motional and physiological information of the driver using the developed wearable device on the wrist. Preprocessing is used to distinguish the valid signal parts of the measured signals, because various noises can occur in wearable sensors. Features are extracted from the signal parts, and an optimal feature set is determined by an analysis of variance and a sequential floating forward selection algorithm. To classify the driver's state, a support vector machine-based classification method is used to obtain high generalization performance considering interdriver variance. Experiments were conducted on an indoor driving simulator, with 28 subjects, to gather data for each state. The classification accuracy was 98.43% for fivefold cross validation on the data. In a subject-independent test, the accuracy was 68.31% for the four states and 84.46% for the three states consisting of normal, stressed, and fatigued or drowsy states. Using the proposed system, the abnormal conditions of the driver can be detected and distinguished. This advantage contributes to safer and more comfortable driving. Furthermore, the utilization of the wearable device makes the system easy to use.

1 November 2019 in Expert Systems with Applications
Verified
Journal Article
Closed access
JLJun Seong Lee
Jun Seong Lee
SLSang Jun Lee
Sang Jun Lee
MCMinho Choi
Minho Choi
MSMinseok Seo
Minseok Seo
SKSang Woo Kim
Sang Woo Kim

17 May 2016 in Sensors
Verified
Journal Article
Open access
PDF file
MCMinho Choi
Minho Choi
JJJAE JIN JEONG
JAE JIN JEONG
SKSeung Hun Kim
Seung Hun Kim
SKSang Woo Kim
Sang Woo Kim
Non-intrusive electrocardiogram (ECG) monitoring has many advantages: easy to measure and apply in daily life. However, motion noise in the measured signal is the major problem of non-intrusive measurement. This paper proposes a method to reduce the noise and to detect the R peaks of ECG in a stable manner in a sitting arrangement using non-intrusive sensors. The method utilizes two capacitive ECG sensors (cECGs) to measure ECG, and another two cECGs located adjacent to the sensors for ECG are added to obtain the information on motion. Then, active noise cancellation technique and the motion information are used to reduce motion noise. To verify the proposed method, ECG was measured indoors and during driving, and the accuracy of the detected R peaks was compared. After applying the method, the sum of sensitivity and positive predictivity increased 8.39% on average and 26.26% maximally in the data. Based on the results, it was confirmed that the motion noise was reduced and that more reliable R peak positions could be obtained by the proposed method. The robustness of the new ECG measurement method will elicit benefits to various health care systems that require noninvasive heart rate or heart rate variability measurements.

29 June 2018 in Sensors
Verified
Journal Article
Open access
PDF file
MSMinseok Seo
Minseok Seo
MCMinho Choi
Minho Choi
JLJun Seong Lee
Jun Seong Lee
SKSang Woo Kim
Sang Woo Kim
Electrocardiograms (ECGs) can be conveniently obtained using capacitive ECG sensors. However, motion noise in measured ECGs can degrade R peak detection. To reduce noise, properties of reference signal and ECG measured by the sensors are analyzed and a new method of active noise cancellation (ANC) is proposed in this study. In the proposed algorithm, the original ECG signal at QRS interval is regarded as impulsive noise because the adaptive filter updates its weight as if impulsive noise is added. As the proposed algorithm does not affect impulsive noise, the original signal is not reduced during ANC. Therefore, the proposed algorithm can conserve the power of the original signal within the QRS interval and reduce only the power of noise at other intervals. The proposed algorithm was verified through comparisons with recent research using data from both indoor and outdoor experiments. The proposed algorithm will benefit a noise reduction of noisy biomedical signal measured from sensors.

23 May 2022 in IEEE Access
Verified
Journal Article
Open access
MCMinho Choi
Minho Choi
SLSang-Jin Lee
Sang-Jin Lee
Blood pressure measurement is required to monitor the cardiovascular state of a person, and it is commonly conducted in a noninvasive way using oscillometry-based blood pressure monitors (BPM). Blood pressure can be estimated by analyzing the oscillometric waveform (OMW) in the BPM, and many methods have been examined to increase their estimation accuracy. In this study, we proposed a new method that enhances estimation accuracy and requires no external user information, such as age and gender, in the test phase. In the method, the entire OMW was considered as an input to reduce information loss via feature extraction, and convolutional neural networks were utilized to effectively analyze the high-dimensional input. Additionally, the proposed method included a novel ensemble method to further increase the estimation accuracy. The performance of the proposed method was evaluated and compared with other studies via subject-independent tests considering real situations in which it is difficult to obtain preliminary information on a test subject. Data from 64 subjects were used in the test. The mean absolute error of the proposed method was 3.12 and 3.98 mmHg for systolic and diastolic blood pressure, respectively, which was superior to those reported in other studies conducted in similar conditions. Individuals can measure their blood pressure with higher precision using the proposed method with improved estimation performance. This can aid in reducing the risk of cardiovascular diseases.