Pasquale CUSUMANO

Dr. Pasquale CUSUMANO

orcid

Research Focus & Metrics

Academic Career Length

24Years (2003-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 October 2003 in Synthetic Metals
Verified
Journal Article
Closed access
PCPasquale CUSUMANO
Pasquale CUSUMANO
FBF. Buttitta
F. Buttitta
ACA. Di Cristofalo
A. Di Cristofalo
CCC. Calı
C. Calı

1 January 2020 in Electronics
Verified
Journal Article
Open access
PDF file
PCPasquale CUSUMANO
Pasquale CUSUMANO
CAClaudio Arnone
Claudio Arnone
MGMarco Angelo Giambra
Marco Angelo Giambra
APAntonino Parisi
Antonino Parisi
The operation and the design of organic solar cells with donor/acceptor heterojunction structure and exciton blocking layer is outlined and results of their initial development and assessment are reported. Under halogen lamp illumination with 100 mW/cm2 incident optical power density, the devices exhibits an open circuit voltage VOC = 0.45 V, a short circuit current density JSC between 2 and 2.5 mA/cm2 with a fill factor FF ≈ 50%, an external quantum efficiency (electrons/s over incident photons/s) EQE ≈ 5% and a power conversion efficiency of about 0.5%. Measurements of the photoelectrical characteristics with time are also reported, confirming that non encapsulated organic solar cells have limited stability in ambient atmosphere.

22 August 2022 in Sensors
Verified
Journal Article
Open access
PDF file
FAFrancesco Alonge
Francesco Alonge
PCPasquale CUSUMANO
Pasquale CUSUMANO
FDFilippo D'Ippolito
Filippo D'Ippolito
GGGiovanni Garraffa
Giovanni Garraffa
Patrizia LivreriPatrizia Livreri
Patrizia Livreri
Antonino SferlazzaAntonino Sferlazza
Antonino Sferlazza
In this work, a novel scheme for velocity and position estimation in a UWB range-based localization system is proposed. The suggested estimation strategy allows to overcome two main problems typically encountered in the localization systems. The first one is that it can be suitable for use in environments where the GPS signal is not present or where it might fail. The second one is that no accelerometer measurements are needed for the localization task. Moreover, to deal with the velocity estimation problem, a suitable Kalman–Bucy filter is designed and it is compared, experimentally, with a particle filter by showing the features of the two algorithms in order to be used in a localization context. Additionally, further experimental tests are carried out on a suitable developed test setup in order to confirm the goodness of the proposed approach.

29 June 2022 in IEEE Transactions on Electron Devices
Verified
Journal Article
Open access
GMGiacomo Migliore
Giacomo Migliore
AMAntonino Muratore
Antonino Muratore
ABAlessandro Busacca
Alessandro Busacca
PCPasquale CUSUMANO
Pasquale CUSUMANO
SSSalvatore Stivala
Salvatore Stivala
We present a novel configuration for an axial virtual cathode oscillator (Vircator) operating in the ${C}$ -band and designed for high output power applications. In order to enhance the efficiency, we have employed a geometry with up to seven reflectors along the drift space. While in previous research works this optimization process has been performed only varying the reflectors radii while using a fixed distance between reflectors, in our work we propose an optimization in terms of both reflectors radii and distances. Our optimized structure for the axial Vircator is able to provide an efficiency up to 15.6% and an output power of 1.6 GW in the ${C}$ -band, with a working voltage of 510 kV and a cathodic current of 24 kA.

11 July 2025 in Electronics
Verified
Journal Article
Open access
PDF file
PCPasquale CUSUMANO
Pasquale CUSUMANO
ASAlessandro Sirchia
Alessandro Sirchia
FVFlavio Vella
Flavio Vella
Dynamic on-resistance (RON) of commercial GaN on Si normally off high-electron-mobility transistor (HEMT) devices is a very important parameter because it is responsible for conduction losses that limit the power conversion efficiency of high-power switching converters. Due to charge trapping effects, dynamic RON is always higher than in DC, a behavior known as current collapse. To study how short-time dynamics of charge trapping and release affects RON we use rectangular 0–5 V gate voltage pulses with durations in the 1 μs to 100 μs range. Measurements are first carried out for single pulses of increasing duration, and it is found that RON depends on both pulse duration and drain current ID, being higher at shorter pulse durations and lower ID. For a train of five pulses, RON decreases with pulse number, reaching a steady state after a time interval of 100 μs. The response to a five pulses train is compared to that of a square-wave signal to study the time evolution of RON toward a dynamic steady state. The DC RON is also measured, and it is a factor of ten smaller than dynamic RON at the same ID. This confirms that a reduction in trapped charges takes place in DC as compared to the square-wave switching operation. Additional off-state stress tests at VDS = 55 V reveal the presence of residual surface traps in the drain access region, leading to four times increase in RON in comparison to pristine devices. Finally, the dynamic RON is also measured by the double-pulse test (DPT) technique with inductive load, giving a good agreement with results from single-pulse measurements.

13 May 2025 in Electronics
Verified
Journal Article
Open access
PDF file
PCPasquale CUSUMANO
Pasquale CUSUMANO
FVFlavio Vella
Flavio Vella
ASAlessandro Sirchia
Alessandro Sirchia
Charge carrier traps due to crystal defects in GaN on Si HEMT devices are responsible for dynamic performance degradation, long-term reliability limitations, and peculiar failure modes. The behavior of traps depends on many variables including heterostructure quality, the specific device structure, and operating conditions. To study the short time dynamics of charge trapping and release on the threshold voltage shift and hysteresis of commercial normally off GaN HEMTs we use triangular 0–5 V gate voltage pulses in the μs to ms duration range. Measurements are performed for single pulses by varying pulse duration and for a train of a few pulses by varying their number. The results indicate that hysteresis and related threshold voltage shift occur after repeated pulses, suggesting an accumulation of trapped charges. However, for a triangular wave hysteresis vanishes, meaning that a dynamic balance between charge trapping and release is established in the device. This can be considered as a positive indicator of device robustness and reliability. The same method, used to measure the gate threshold voltage shift and dynamic RON after a 30 min off-state DC stress at VDS = 55 V with a floating gate, highlights an appreciable performance degradation of the device.