Antonino Parisi

Dr. Antonino Parisi


Research Focus & Metrics

Academic Career Length

23Years (2004-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2015 in International Journal of Photoenergy
Verified
Journal Article
Open access
PDF file
APAntonino Parisi
Antonino Parisi
Riccardo PerniceRiccardo Pernice
Riccardo Pernice
VRVincenzo Rocca
Vincenzo Rocca
LCLuciano Curcio
Luciano Curcio
SSSalvatore Stivala
Salvatore Stivala
ABAlessandro C. Busacca
Alessandro C. Busacca
We demonstrate an innovative CIGS-based solar cells model with a graded doping concentration absorber profile, capable of achieving high efficiency values. In detail, we start with an in-depth discussion concerning the parametrical study of conventional CIGS solar cells structures. We have used the wxAMPS software in order to numerically simulate cell electrical behaviour. By means of simulations, we have studied the variation of relevant physical and chemical parameters—characteristic of such devices—with changing energy gap and doping density of the absorber layer. Our results show that, in uniform CIGS cell, the efficiency, the open circuit voltage, and short circuit current heavily depend on CIGS band gap. Our numerical analysis highlights that the band gap value of 1.40 eV is optimal, but both the presence of Molybdenum back contact and the high carrier recombination near the junction noticeably reduce the crucial electrical parameters. For the above-mentioned reasons, we have demonstrated that the efficiency obtained by conventional CIGS cells is lower if compared to the values reached by our proposed graded carrier concentration profile structures (up to 21%).

18 May 2023 in Electrochimica Acta
Verified
Journal Article
Open access
BPBernardo Patella
Bernardo Patella
APAntonino Parisi
Antonino Parisi
NMNadia Moukri
Nadia Moukri
FGFederico Gitto
Federico Gitto
ABAlessandro Busacca
Alessandro Busacca
Rosalinda InguantaRosalinda Inguanta
Rosalinda Inguanta

11 November 2008 in Sensors
Verified
Journal Article
Open access
PDF file
APAntonino Parisi
Antonino Parisi
ACAlfonso C. Cino
Alfonso C. Cino
ABAlessandro C. Busacca
Alessandro C. Busacca
MCMatteo Cherchi
Matteo Cherchi
SRStefano Riva-Sanseverino
Stefano Riva-Sanseverino
The surface plasmon resonance (SPR) technique is a well-known optical method that can be used to measure the refractive index of organic nano-layers adsorbed on a thin metal film. Although there are many configurations for measuring biomolecular interactions, SPR-based techniques play a central role in many current biosensing experiments, since they are the most suited for sensitive and quantitative kinetic measurements. Here we give some results from the analysis and numerical elaboration of SPR data from integrated optics experiments in a particular borosilicate glass, chosen for its composition offering the rather low refractive index of 1.4701 at 633 nm wavelength. These data regard the flow over the sensing region (metal window) of different solutions with refractive indexes in the range of interest (1.3÷1.5) for the detection of contaminants in aqueous solutions. After a discussion of the principles of SPR, of the metal window design optimization by means of optical interaction numerical modeling, and of waveguide fabrication techniques, we give a description of system setup and experimental results. Optimum gold film window thickness and width in this guided-wave configuration has been for the first time derived and implemented on an integrated optic prototype device. Its characterization is given by means of the real time waveguide output intensity measurements, which correspond to the interaction between the sensing gold thin film window and the flowing analyte. The SPR curve was subsequently inferred. Finally, a modified version of the device is reported, with channel waveguides arranged in a Y-junction optical circuit, so that laser source stability requirements are lowered by a factor of 85 dB, making possible the use of low cost sources in practical applications.

5 April 2023 in Biosensors
Verified
Journal Article
Open access
PDF file
SVSimone Valenti
Simone Valenti
GVGabriele Volpes
Gabriele Volpes
APAntonino Parisi
Antonino Parisi
DPDaniele Peri
Daniele Peri
Jinseok LeeJinseok Lee
Jinseok Lee
Riccardo PerniceRiccardo Pernice
Riccardo Pernice
The increasing interest in innovative solutions for health and physiological monitoring has recently fostered the development of smaller biomedical devices. These devices are capable of recording an increasingly large number of biosignals simultaneously, while maximizing the user’s comfort. In this study, we have designed and realized a novel wearable multisensor ring-shaped probe that enables synchronous, real-time acquisition of photoplethysmographic (PPG) and galvanic skin response (GSR) signals. The device integrates both the PPG and GSR sensors onto a single probe that can be easily placed on the finger, thereby minimizing the device footprint and overall size. The system enables the extraction of various physiological indices, including heart rate (HR) and its variability, oxygen saturation (SpO2), and GSR levels, as well as their dynamic changes over time, to facilitate the detection of different physiological states, e.g., rest and stress. After a preliminary SpO2 calibration procedure, measurements have been carried out in laboratory on healthy subjects to demonstrate the feasibility of using our system to detect rapid changes in HR, skin conductance, and SpO2 across various physiological conditions (i.e., rest, sudden stress-like situation and breath holding). The early findings encourage the use of the device in daily-life conditions for real-time monitoring of different physiological states.

1 October 2013 in IEEE Transactions on Electron Devices
Verified
Journal Article
Open access
GAGabriele Adamo
Gabriele Adamo
DADiego Agro
Diego Agro
SSSalvatore Stivala
Salvatore Stivala
APAntonino Parisi
Antonino Parisi
Giuseppe GiaconiaGiuseppe Giaconia
Giuseppe Giaconia
GFGiorgio Fallica
Giorgio Fallica
We report on the electrical and optical characterization, in continuous wave regime, of a novel class of silicon photomultipliers fabricated in standard planar technology on a silicon p-type substrate. Responsivity measurements, performed with an incident optical power down to tenths of picowatts, at different reverse bias voltages and on a broad (340-820 nm) spectrum, will be shown and discussed. The device temperature was monitored, allowing us to give a physical interpretation of the measurements. The obtained results demonstrate that such novel silicon photomultipliers are suitable as sensitive power meters for low photon fluxes.

20 April 2024 in Biosensors
Verified
Journal Article
Open access
PDF file
GVGabriele Volpes
Gabriele Volpes
SVSimone Valenti
Simone Valenti
GGGiuseppe Genova
Giuseppe Genova
CBChiara Barà
Chiara Barà
APAntonino Parisi
Antonino Parisi
Riccardo PerniceRiccardo Pernice
Riccardo Pernice
Wearable health devices (WHDs) are rapidly gaining ground in the biomedical field due to their ability to monitor the individual physiological state in everyday life scenarios, while providing a comfortable wear experience. This study introduces a novel wearable biomedical device capable of synchronously acquiring electrocardiographic (ECG), photoplethysmographic (PPG), galvanic skin response (GSR) and motion signals. The device has been specifically designed to be worn on a finger, enabling the acquisition of all biosignals directly on the fingertips, offering the significant advantage of being very comfortable and easy to be employed by the users. The simultaneous acquisition of different biosignals allows the extraction of important physiological indices, such as heart rate (HR) and its variability (HRV), pulse arrival time (PAT), GSR level, blood oxygenation level (SpO2), and respiratory rate, as well as motion detection, enabling the assessment of physiological states, together with the detection of potential physical and mental stress conditions. Preliminary measurements have been conducted on healthy subjects using a measurement protocol consisting of resting states (i.e., SUPINE and SIT) alternated with physiological stress conditions (i.e., STAND and WALK). Statistical analyses have been carried out among the distributions of the physiological indices extracted in time, frequency, and information domains, evaluated under different physiological conditions. The results of our analyses demonstrate the capability of the device to detect changes between rest and stress conditions, thereby encouraging its use for assessing individuals’ physiological state. Furthermore, the possibility of performing synchronous acquisitions of PPG and ECG signals has allowed us to compare HRV and pulse rate variability (PRV) indices, so as to corroborate the reliability of PRV analysis under stationary physical conditions. Finally, the study confirms the already known limitations of wearable devices during physical activities, suggesting the use of algorithms for motion artifact correction.