Lactate measurement is important in the fields of sports and medicine. Lactate accumulation can seriously affect an athlete’s performance. The most common problem caused by lactate accumulation in athletes is muscle soreness due to excessive exercise. Moreover, from a medical viewpoint, lactate is one of the main prognostic factors of sepsis. Currently, blood sampling is the most common approach to lactate measurement for lactate sensing, and continuous measurement is not available. In this study, a low-cost continuous lactate monitoring system (CLMS) is developed based on a percutaneous microneedle array that uses a three-electrode lactate sensor. The working electrode has an area of 10 mm × 6 mm, including a 3 × 3 array of stainless-steel microneedles. The length, width, and thickness of each needle are 1 mm, 0.44 mm, and 0.03 mm, respectively. The working electrode is then plated with gold, polyaniline, lactate enzyme, Nafion, and Poly(2-hydroxyethyl methacrylate) (poly HEMA). The reference electrode is a 2 × 1 array covered with AgCl, and the counter electrode is a 2 × 1 array plated with gold. The sensor is incorporated into the CLMS and connected to a smartphone application and the cloud. The CLMS was tested on 40 human subjects who rode indoor bicycles, starting at 100 W and increasing in steps of 25 W at intervals of 5 min until exhaustion. The data acquired from the app connected to the CLMS were analyzed to determine the subjects’ lactate response to exercise and the feasibility of assessing exercise performance and training exercise intensity by using the proposed system.
A fall is one of the most devastating events that aging people can experience. Fall-related physical injuries, hospital admission, or even mortality among the elderly are all critical health issues. As the population continues to age worldwide, there is an imperative need to develop fall detection systems. We propose a system for the recognition and verification of falls based on a chest-worn wearable device, which can be used for elderly health institutions or home care. The wearable device utilizes a built-in three-axis accelerometer and gyroscope in the nine-axis inertial sensor to determine the user’s postures, such as standing, sitting, and lying down. The resultant force was obtained by calculation with three-axis acceleration. Integration of three-axis acceleration and a three-axis gyroscope can obtain a pitch angle through the gradient descent algorithm. The height value was converted from a barometer. Integration of the pitch angle with the height value can determine the behavior state including sitting down, standing up, walking, lying down, and falling. In our study, we can clearly determine the direction of the fall. Acceleration changes during the fall can determine the force of the impact. Furthermore, with the IoT (Internet of Things) and smart speakers, we can verify whether the user has fallen by asking from smart speakers. In this study, posture determination is operated directly on the wearable device through the state machine. The ability to recognize and report a fall event in real-time can help to lessen the response time of a caregiver. The family members or care provider monitor, in real-time, the user’s current posture via a mobile device app or internet webpage. All collected data supports subsequent medical evaluation and further intervention.
A continuous blood glucose monitoring system (CGMS) which include a microneedle-array blood glucose sensor, a circuit module, and a transmission module placed in a wearable device is developed in this research. When in use, the wearable device is attached to the human body with the microneedle array inserted under the skin for continuous blood glucose sensing, and the measured signals are transmitted wirelessly to a mobile phone or computer for analysis. The purpose of this study is to replace the conventionally used method of puncture for blood collection and test strips are used to measure the blood glucose signals. The microneedle sensor of this CGMS uses a 1 mm length needle in a 3 mm × 3 mm microneedle array for percutaneous minimally invasive blood glucose measurement. This size of microneedle does not cause bleeding damage to the body when used. The microneedle sensor is placed under the skin and their solutions are discussed. The blood glucose sensor measured the in vitro simulant fluid with a glucose concentration range of 50~400 mg/dL. In addition, a micro-transfer method is developed to accurately deposit the enzyme onto the tip of the microneedle, after which cyclic voltammetry (CV) is used to measure the glucose simulation solution to verify whether the difference in the amount of enzyme on each microneedle is less than 10%. Finally, various experiments and analyses are carried out to reduce the size of the device, test effective durability (approximately 7 days), and the feasibility of minimally invasive CGMS is evaluated by tests on two persons.
1 August 2022 in The International Journal of Advanced Manufacturing Technology
In recent years, the use of reinforcement learning and imitation learning to complete robot control tasks have become more popular. Demonstration and learning by experts have always been the goal of researchers. However, the lack of action data has been a significant limitation to learning by human demonstration. We propose an architecture based on a new 3D keypoint tracking model and generative adversarial imitation learning to learn from expert demonstrations. We used 3D keypoint tracking to make up for the lack of action data in simple images and then used image-to-image conversion to convert human hand demonstrations into robot images, which enabled subsequent generative adversarial imitation learning to learn smoothly. The estimation time of the 3D keypoint tracking model and the calculation time of the subsequent optimization algorithm was 30 ms. The coordinate errors of the model projected to the real 3D key point under correct detection were all within 1.8 cm. The tracking of key points did not require any sensors on the body; the operator did not need vision-related knowledge to correct the accuracy of the camera. By merely setting up a generic depth camera to track the mapping changes of key points after behavior clone training, the robot could learn human tasks by watching, including picking and placing an object and pouring water. We used pybullet to build an experimental environment to confirm our concept of the simplest behavioral cloning imitation to attest the success of the learning. The effectiveness of the proposed method was accomplished by a satisfactory performance requiring a sample efficiency of 20 sets for pick and place and 30 sets for pouring water.
Balanced nutrition plays a vital role in preventing chronic diseases. We propose a home-based monitoring system that integrates an Nvidia Jetson AGX Xavier embedded device with an Intel RealSense D435 depth camera mounted vertically above the dining table. The system collects data every minute during meals, capturing point clouds with RGB information. Deep-learning object detection models identify and track multiple food items, ensuring each item is recognized independently. Point clouds are aligned using Random Sample Consensus (RANSAC) and Iterative Closest Point (ICP), while Density-Based Spatial Clustering of Applications with Noise (DBSCAN) distinguishes the table, plate, and food. The system records temporal changes in meal portions and reconstructs food point clouds to estimate volume. Each estimate is linked to the corresponding food category predicted by the semantic segmentation model and combined with nutritional values. All data are uploaded to the cloud, enabling user analysis along with preliminary assessments of total nutrient intake and eating speed. By integrating these components, the system provides accurate records of meal volume and composition, supporting comprehensive evaluations of home-based nutrition over a three-month period.
About Me
Professor, National Taipei University of Technology
Professor, National Taipei University of Technology