The study objective was to compare titration of positive end-expiratory pressure (PEEP) with electrical impedance tomography (EIT) and with ventilator-embedded pressure–volume loop in severe acute respiratory distress syndrome (ARDS). We have designed a prospective study with historical control group. Twenty-four severe ARDS patients (arterial oxygen partial pressure to fractional inspired oxygen ratio, PaO2/FiO2 < 100 mmHg) were included in the EIT group and examined prospectively. Data from another 31 severe ARDS patients were evaluated retrospectively (control group). All patients were receiving medical care under identical general support guidelines and protective mechanical ventilation. The PEEP level selected in the EIT group was the intercept point of cumulated collapse and overdistension percentages curves. In the control group, optimal PEEP was selected 2 cmH2O above the lower inflection point on the static pressure–volume curve. Patients in the EIT group were younger (P < 0.05), and their mean plateau pressure was 1.5 cmH2O higher (P < 0.01). No differences in other baseline parameters such as APACHE II score, PaO2/FiO2, initial PEEP, driving pressure, tidal volume, and respiratory system compliance were found. Two hours after the first PEEP titration, significantly higher PEEP, compliance, and lower driving pressure were found in the EIT group (P < 0.01). Hospital survival rates were 66.7% (16 of 24 patients) in the EIT group and 48.4% (15 of 31) in the control group. Identical rates were found regarding the weaning success rate: 66.7% in the EIT group and 48.4% in the control group. In severe ARDS patients, it was feasible and safe to guide PEEP titration with EIT at the bedside. As compared with pressure–volume curve, the EIT-guided PEEP titration may be associated with improved oxygenation, compliance, driving pressure, and weaning success rate. The findings encourage further randomized control study with a larger sample size and potentially less bias in the baseline data. Trial Registration NCT03112512
A kinesin family member 5b (KIF5B)-MET proto-oncogene, receptor tyrosine kinase (MET) rearrangement was reported in patients with lung adenocarcinoma but its oncogenic function was not fully evaluated. We used one-step reverse transcription-polymerase chain reaction for RNA samples to screen for the KIF5B-MET fusion in 206 lung adenocarcinoma and 28 pulmonary sarcomatoid carcinoma patients. Genomic breakpoints of KIF5B-MET were determined by targeted next-generation sequencing. Soft agar colony formation assays, proliferation assays, and a xenograft mouse model were used to investigate its oncogenic activity. In addition, specific MET inhibitors were administered to evaluate their anti-tumor activities. A KIF5B-MET fusion variant in a patient with a mixed-type adenocarcinoma and sarcomatoid tumor was identified, and another case was found in a pulmonary sarcomatoid carcinoma patient. Both cases carried the same chimeric gene, a fusion between exons 1-24 of KIF5B and exons 15-21 of MET. KIF5B-MET-overexpressing cells exhibited significantly increased proliferation and colony-forming ability. Xenograft tumors harboring the fusion gene demonstrated significantly elevated tumor growth. Ectopic expression of the fusion gene stimulated the phosphorylation of KIF5B-MET as well as downstream STAT3, AKT, and ERK1/2 signaling pathways. The MET inhibitors significantly repressed cell proliferation; phosphorylation of downstream STAT3, AKT, and ERK1/2; and xenograft tumorigenicity. In conclusion, the KIF5B-MET variant was demonstrated to have an oncogenic function in cancer cells. These findings have immediate clinical implications for the targeted therapy of subgroups of non-small cell lung cancer patients.
Since bronchial abnormalities often exhibit spatial non-uniformity which may be not correctly assessed by conventional global lung function measures, regional information may help to characterize the disease progress. We hypothesized that regional air trapping during mechanical ventilation could be characterized by regional end-expiratory flow (EEF) derived from electrical impedance tomography (EIT). Twenty-five patients suffering from chronic obstructive pulmonary disease (COPD grade 3 or 4) or severe asthma with acute exacerbation were examined prospectively. Patients were ventilated under assist-control mode. EIT measurements were conducted before and one hour after inhaled combined corticosteroid and long-acting β2 agonist, on two consecutive days. Regional EEF was calculated as derivative of relative impedance for every image pixel in the lung regions. The results were normalized to global flow values measured by the ventilator. Regional and global EEF were highly correlated (P<0.00001) and regional effects of medication and disease progression were visible in the regional EEF maps. The sums of regional EEF in lung regions were 3.8 [2.0, 5.1] and 3.6 [1.9, 4.5] L/min in COPD patients before and after medication (median [lower, upper quartiles]; P=0.37). The corresponding values in asthma patients were 3.0 [2.5, 4.2] and 2.2 [1.7, 3.2] L/min (P<0.05). Histograms of regional EEF showed high spatial heterogeneity of EEF before medication. After one day of treatment, the histograms exhibited less heterogeneous and a decrease in EEF level. Regional EEF characterizes air trapping and intrinsic PEEP, which could provide diagnostic information for monitoring the disease progress during treatment.
BRAF V600E mutation, a missense mutation in exon 15 resulting in valine substitution for glutamate at position 600 within the kinase domain of BRAF oncogene, is found in a subset of lung adenocarcinoma (ADC). The usefulness of immunohistochemistry (IHC) as an alternative diagnostic tool has not been validated. Moreover, the clinical information of patients with BRAF V600E-mutated lung ADC is limited. We retrospectively identified 31 lung ADCs diagnosed with BRAF V600E mutation by standard molecular sequencing methods and reviewed their clinical characteristics and pathological features. An anti-BRAF V600E monoclonal VE1 antibody for IHC was used to confirm the expression patterns. The series was comprised of 99 cases, 29 with BRAF V600E mutation and 70 without BRAF V600E but with other types or undetected mutations. The majority of BRAF V600E-mutated biopsied tissues were poorly differentiated and micropapillary patterns. Application of the IHC VE1 assay was highly feasible in primary/metastatic sites or effusion blocks, yielding positive findings in 28 of 29 (96.6%) BRAF V600E-mutated tumors and negative results in 69 of 70 (98.6%) tumors harboring other types or undetected mutations. Patients who received pemetrexed/platinum-based rather than mutation-targeted chemotherapy as the first-line therapy for metastatic disease showed median overall survival of 15.5 months. Our findings indicated that VE1 antibody-based IHC analysis demonstrated high sensitivity and specificity to detect BRAF V600E-mutated lung ADCs in tissues from primary or metastatic sites.