Bin Fu

Prof. Bin Fu

orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 May 2019 in IEEE Access
Verified
Journal Article
Open access
JYJiang You
Jiang You
LCLianbin Cheng
Lianbin Cheng
BFBin Fu
Bin Fu
MDMenglu Deng
Menglu Deng
Input-parallel output-series (IPOS) based combined converter is usually used in the situation with low input voltage and high output voltage to satisfy the requirements in switch voltage stress reduction and power expansion. In such a system, voltage balance of filter capacitor in the output side or current sharing in the input side usually used to guarantee the control performance of the conversion system. In this paper, a phase-shifted full bridge (PSFB) based IPOS converter with modified connection of output filter circuit used for wide variation of input voltage is proposed, which is beneficial to reduce ripple current of filter inductor significantly. A control scheme using the same phase shifting for the two different modules of this IPOS converter is detailedly investigated with both steady state and small signal model based analysis, it manifests that special voltage balance and current sharing control scheme are not necessary in IPOS system under the common phase shifting control method. And the small signal transfer functions of this topology used for dual loop control system design are also developed. Simulation and experiment results are presented to validate the analysis and control scheme.

1 April 2019 in IEEE Access
Verified
Journal Article
Open access
JYJiang You
Jiang You
WFWeiyan Fan
Weiyan Fan
RSRong Sun
Rong Sun
BFBin Fu
Bin Fu
In traditional hybrid energy storage system (HESS), separated bidirectional DC/DC converter is usually used to interface energy storage system with DC bus. Though it has advantage in flexibility of control system design using separated power converters, it results in more switches, auxiliary components and cost for the whole system development. Particularly, since the energy storage system (ESS) designed for high dynamic compensation (e.g., supercapacitor) is mainly used to provide high dynamic compensation in transient state process, the utilization rate of the corresponding interface DC/DC converter is relatively low. On the other hand, the DC bus voltage compensation performance will be discounted due to inherent time delay for the current reference signal production of HESS with outer loop voltage control. To address these two issues, an integrated topology of hybrid energy storage system is proposed in this paper, and an improved control method that has ability to enhance the control performance of HESS to compensate the DC bus voltage is developed too. Experimental test results are provided to validate the correctness and effectiveness of the proposed methods.

12 June 2019 in Energies
Verified
Journal Article
Open access
PDF file
JYJiang You
Jiang You
HLHongsheng Liu
Hongsheng Liu
BFBin Fu
Bin Fu
XXXingyan Xiong
Xingyan Xiong
The three-port converter (TPC) obtains major attention due to its power density and ability to dispose different electric powers flexibly. Since the control models of the TPC are derived from particular steady state work point through small signal modeling method, the model parameters usually be deviated from their normal values with the change of operation and load conditions. Furthermore, there are couplings and interactions in power delivery between different ports, which have a significant influence in the dynamic control performance of the system. In this paper, the H∞ mixed sensitivity method is employed to design robust controllers for a TPC control system. Simulation results are given to demonstrate the effectiveness of the proposed scheme, and experimental studies are conducted on a prototype circuit to further validate the developed method. Compared to a traditional PI controller, it shows that a mixed sensitivity based robust controller manifest balanced performance in model parameters changes attenuation and dynamic control performance.