Jiang You

Jiang You

Auto-generated profile, based on publicly available information

Jiang You

Yantai Research Institute, Harbin Engineering University, Yantai, China

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 December 2024 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
Bo LuoBo Luo
Bo Luo
HWHuan Wu
Huan Wu
MWMengyao Wang
Mengyao Wang
FWFangrui Wang
Fangrui Wang
LBLonglei Bai
Longlei Bai
JYJiang You
Jiang You
Monitoring coupler parameters in underwater wireless power transfer (UWPT) systems is crucial for improving the system transmission characteristics. Due to the eddy current effect, the equivalent circuits of the magnetic coupler are more complex and contain more parameters than those in air-based circuits. Traditional parameter identification methods, which rely on solving circuit matrix equations, often struggle with the complex UWPT systems or require significant computational resources to solve high-order multivariate equations. This article proposes a coupler parameter identification method based on the adaptive moment estimation with a weighted adjustment (Adam-W) optimization algorithm to address the multiparameter identification problems in the UWPT system. This method transforms the problem of solving high-order matrix equations into an optimization problem to address multiparameter identification problem caused by seawater eddy effect, which is challenging for traditional methods. In addition, it facilitates online monitoring of the characteristic parameters of the system's coupler by detecting the system's front-end input current and voltage without wireless communication and additional sensor modules, and exhibits better reliability in underwater environments. The experimental results show that the proposed Adam-W algorithm achieves a high parameter identification accuracy within 1 s and 94 iterations with an average error of 2.78%. Comparably, an average error of 56.74% is achieved by gradient descent and 41.49% by adaptive moment estimation, and 37.42% by particle swarm optimization in 150 iterations. The proposed Adam-W algorithm achieves higher accuracy in parameter identification of the UWPT system within a shorter time and demonstrates better applicability in seawater environments.

4 March 2025 in IEEE Transactions on Transportation Electrification
Verified
Journal Article
Closed access
LBLonglei Bai
Longlei Bai
JYJu Ye
Ju Ye
ZMZhiyong Ma
Zhiyong Ma
ZZZiye Zhang
Ziye Zhang
Chaoqiang JiangChaoqiang Jiang
Chaoqiang Jiang
LSLiangshun Sun
Liangshun Sun
In the realm of underwater wireless power transmission systems, it is crucial to acquire system parameters accurately to ensure output stability. However, measuring these parameters in underwater environments presents a huge challenge. As a result, simplifying measurements through parameter identification becomes essential. The circuit model of the underwater wireless power transfer (WPT) system may require adjustments due to seawater conductivity, and utilizing current parameter identification methods is applicable to air, which can lead to notable inaccuracies in underwater parameter identification. This article presents an analytical model of the mutual inductance in the underwater WPT system, analyzes its impact on output power and transmission efficiency, and proposes a mutual inductance and load parameter identification method suitable for underwater WPT systems. This method identifies mutual inductance and load values by measuring the input impedance of the equivalent load network on the inverter side at both resonant and nonresonant frequencies. The parameter identification model of the proposed underwater WPT system has been theoretically derived and experimentally verified using the seriesseries (SS) compensation topology. The experimental results illustrate that the proposed parameter identification method effectively identifies both the mutual inductance model and the load of the underwater WPT system, with the load identification error being less than 2% and the mutual inductance identification error being less than 5%. Furthermore, mutual inductance and load information can be obtained from the primary side without communication, and the output voltage is controlled with an accuracy of less than 1.2% through parameter identification.

6 June 2024 in IEEE Transactions on Industry Applications
Verified
Journal Article
Closed access
Bo LuoBo Luo
Bo Luo
YLYuezhong Liu
Yuezhong Liu
YZYiming Zhang
Yiming Zhang
LBLonglei Bai
Longlei Bai
YZYao Zhang
Yao Zhang
Ruikun MaiRuikun Mai
Ruikun Mai
Electronically controlled pneumatic (ECP) system is essential to ensure the railway transportation system's braking safety. Traditionally, the ECP system needs a long cable to supply power for each train body's brake controller. However, a train has many bumps, and the transmission lines and plugs easily fall off simultaneously. It brings severe challenges to the safe and reliable operation of the railway system. This paper proposes a capacitive power transfer (CPT) system to supply power for a long-distance and multiple-load ECP brake system to solve this problem. The proposed system has the following characteristics: 1. It can supply power to multiple loads simultaneously; 2. The variation of load resistance will not affect the other load; 3. The output of each load will not be largely affected by the coupler misalignment. The transmitter of the proposed CPT system adopts CL compensation, while the receivers adopt LCCL topology. The receiver not only receives the electric power for the load but also transfers the power to the next load. A scaled-down experimental prototype with three loads was implemented to verify the proposed theory. The experimental results agree well with the analysis. With a 200mm misalignment (2/3 length of coupler plates), the output power can reach 83.32W (150W rated). The change rate of the output voltage is less than 12% when other receivers are moved out.

16 January 2019 in Energies
Verified
Journal Article
Open access
PDF file
JYJiang You
Jiang You
WFWeiyan Fan
Weiyan Fan
LYLijun Yu
Lijun Yu
BFBin Fu
Bin Fu
MLMengyan Liao
Mengyan Liao
Since it has strong ability to realize a conversion to adapt to a wide variation of input voltage, the double-switch buck-boost (DSBB) converter is usually employed as a front-end converter in two-stage power converter systems, where conversion efficiency is always highly valued. Because there is only one switch in the Pulse Width Modulation (PWM) state in the buck or boost work mode, the combined control scheme was investigated for its advantages in inductor average current and conversion efficiency. However, in this method, the operation mode should be determined by additional logic according to the change of input voltage. Moreover, different control systems should be designed for different operation modes to guarantee dynamic control performance and smooth transition between different work modes. To address these issues, the linear active disturbance rejection control (LADRC) method is introduced to develop an inner current control loop in this paper. In this method, the model deviations in different work modes are considered as a generalized disturbance, and a unified current control plant can be derived for current controller design. Furthermore, the duty cycle limitations in practice are considered, an additional mode for transitional operation is produced, and the corresponding control scheme is also developed. Simulation and experimental test results are provided to validate the correctness and effectiveness of the proposed control scheme.

22 July 2025 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
Bo LuoBo Luo
Bo Luo
MWMengyao Wang
Mengyao Wang
JTJie Tang
Jie Tang
TWTiantian Wang
Tiantian Wang
LBLonglei Bai
Longlei Bai
JYJiang You
Jiang You
An underwater simultaneous wireless power and analog-digital hybrid signal transfer system is proposed in this letter to meet the needs of analog and digital signal transmission in underwater sensor networks in seawater. The system transmits two digital signals and one analog signal through the same coil, meeting the practical needs of multiple signal transmissions, improving the communication rate, and retaining the precision and continuity of analog signals as well as the accuracy of digital signals. The system uses a coaxial coil coupling structure, with the outer ring for power transmission and the inner ring for signal transmission, featuring a simple and compact design. The experimental platform achieved a 400W output power, 1Mbps bidirectional digital signal transmission and 20kHz unidirectional analog signal transmission in seawater, with a transmission efficiency of 90.8%, verifying the feasibility of the proposed theory.

12 June 2019 in Energies
Verified
Journal Article
Open access
PDF file
JYJiang You
Jiang You
HLHongsheng Liu
Hongsheng Liu
BFBin Fu
Bin Fu
XXXingyan Xiong
Xingyan Xiong
The three-port converter (TPC) obtains major attention due to its power density and ability to dispose different electric powers flexibly. Since the control models of the TPC are derived from particular steady state work point through small signal modeling method, the model parameters usually be deviated from their normal values with the change of operation and load conditions. Furthermore, there are couplings and interactions in power delivery between different ports, which have a significant influence in the dynamic control performance of the system. In this paper, the H∞ mixed sensitivity method is employed to design robust controllers for a TPC control system. Simulation results are given to demonstrate the effectiveness of the proposed scheme, and experimental studies are conducted on a prototype circuit to further validate the developed method. Compared to a traditional PI controller, it shows that a mixed sensitivity based robust controller manifest balanced performance in model parameters changes attenuation and dynamic control performance.