The development of age-appropriate formulations should focus on dosage forms that can deliver variable yet accurate doses that are safe and acceptable to the child, are matched to his/her development and ability, and avoid medication errors. However, in the past decade, the medication needs of neonates have largely been neglected. The aim of this review is to expand on what differentiates the needs of preterm and term neonates from those of the older paediatric subsets, in terms of environment of care, ability to measure and administer the dose (from the perspective of the patient and carer, the routes of administration, the device and the product), neonatal biopharmaceutics and regulatory challenges. This review offers insight into those challenges posed by the formulation of medicinal products for neonatal patients in order to support the development of clinically relevant products.
Sick neonates with haemodynamic instability often require complex medication regimens, which may result in the connection of a catecholamine infusion distally. This increases the dead volume of the infusion system, extending the time to medication delivery. This study evaluated the effects of body weight, and infusion connection point on the delivery rate of two medications infused through a multi-infusion system at infusion rates suitable for extremely and very low birth weight (ELBW and VLBW) neonates. An infusion system consisting of six infusions was used to investigate time to delivery, drug concentration at time to delivery and quantity of adrenaline and dopamine administered by intravenous infusions at infusion rates suitable for premature neonates. In an ELBW neonate model, the measured adrenaline and dopamine concentration at 12 T was higher than expected (66.7 (7.5)% (mean (SD)) and 68.0 (4.4)%, respectively, P < 0.001). At the calculated time to delivery, neither drug reached target concentration. In a VLBW neonate model, the measured adrenaline and dopamine concentration at 12 T was higher than expected (92.2 (7.1)% and 97.1 (3.1)%, respectively, P < 0.001). Adrenaline reached target concentration at 27 (11) min and dopamine at 56 (12) min, times significantly shorter than calculated. The measured quantity of adrenaline and dopamine delivered was lower (P < 0.001) than calculated in all tested combinations except adrenaline at proximal connection (97.2 (3.4)%, P = 0.097) in the VLBW neonate model. Using the most proximal available infusion connection considerably improves drug delivery times and drug doses delivered, which is critical during the administration of short-acting cardiovascular medications.