Although 3D-printing is common in dentistry, the technique does not produce the required quality for all target applications. Resin type, printing resolution, positioning, alignment, target structure, and the type and number of support structures may influence the surface roughness of printed objects, and this study investigates the effects of these variables. A stereolithographic data record was generated from a master model. Twelve printing processes were executed with a stereolithography Desktop 3D Printer, including models aligned across and parallel to the printer front as well as solid and hollow models. Three layer thicknesses were used, and in half of all processes, the models were inclined at 15°. For comparison, eight gypsum models and milled polyurethane models were manufactured. The mean roughness index of each model was determined with a perthometer. Surface roughness values were approximately 0.65 µm (master), 0.87–4.44 µm (printed), 2.32–2.57 µm (milled), 1.72–1.86 µm (cast plaster/alginate casting), and 0.98–1.03 µm (cast plaster/polyether casting). The layer height and type and number of support structures influenced the surface roughness of printed models (p ≤ 0.05), but positioning, structure, and alignment did not.
1 April 2018 in The Journal of Prosthetic Dentistry
To identify potential risk factors for the development of jaw osteoradionecrosis (ORN) after 3D-conformal radiotherapy (3D-CRT) and intensity-modulated radiotherapy (IMRT) among patients with newly diagnosed head and neck cancer. This study included 776 patients who underwent 3D-CRT or IMRT for head and neck cancer at the Department of Radiotherapy at the University Hospital Halle-Wittenberg between 2003 and 2013. Sex, dental status prior to radiotherapy, tumor site, bone surgery during tumor resection, concomitant chemotherapy, and the development of advanced ORN were documented for each patient. ORN was classified as grade 3, 4, or 5 according to the Radiation Therapy Oncology Group/European Organization for Research and Treatment of Cancer classification or grade 3 or 4 according to the late effects in normal tissues/subjective, objective, management, and analytic scale. The cumulative incidence of ORN was estimated. Cox regression analysis was used to identify prognostic risk factors for the development of ORN. Fifty-one patients developed advanced ORN (relative frequency 6.6 %, cumulative incidence 12.4 %). The highest risk was found in patients who had undergone primary bone surgery during tumor resection (hazard ratio [HR] = 5.87; 95 % confidence interval [CI]: 3.09–11.19) and in patients with tumors located in the oral cavity (HR = 4.69; 95 % CI: 1.33–16.52). Sex, dentition (dentulous vs. edentulous), and chemotherapy had no clinically relevant influence. In contrast to most previous studies, we noted a low cumulative incidence of advanced ORN. Patients with tumors located in the oral cavity and those who undergo bone surgery during tumor resection prior to RT may be considered a high-risk group for the development of ORN.
Removable implant-anchored dentures have become an established treatment concept especially for older, multimorbid patients. This study investigates the retention force (RF) of two different attachment systems. A total of 96 specimens (n = 8 for each condition) were fabricated and RF was measured under different conditions: fatigue (10,000 cycles dislodging), thermal undulation (5/55 °C, 5000 cycles) and implant-angulation (0°, 5°, 10°, 15°, 20°). The Novaloc system ((N), 0° and 15° abutments, yellow matrix (Y)) was compared to the Locator system ((L), pink (P) and orange (O)). Initial RFs (8.57 ± 0.99 N (NY), 19.39 ± 8.10 N (LP), 8.8 ± 5.28 N (LO)) were reduced by ageing simulation (26% (NY), 66% (LP), 89% (LO); p < 0.001). After thermocycling, Novaloc’s RFs decreased by 33% (p < 0.001) while the Locators’ RFs increased by 34% (LP: p = 0.002, LO: p = 0.148). In contrast to LP, the RFs of Novaloc abutments and LOs predominantly showed no clinically relevant dependence on implant angulation. Ageing processes tended to result in lower RFs at higher implant angulation. Thus, the Novaloc attachment system offers an alternative to Locator attachments. It is characterized by a comparatively continuous RF-curve over the entire wearing period. Future clinical studies have to be conducted to verify the in vitro demonstrated advantages of the Novaloc system.
Background: To evaluate the accuracy of a computer numerical control (CNC) milled surgical guide for implant placement in edentulous jaws. Methods: Edentulous patients seeking implants treatment were recruited in this prospective cohort study. Radiographic guides with diagnostic templates were fabricated from wax-up dentures. Patients took cone-beam computed tomography (CBCT) wearing the radiopaque radiographic guides. Implant positions were virtually designed in the planning software based on the CBCT data, and the radiographic templates were converted into surgical guides using CNC milling technique. Forty-four implants were placed into 12 edentulous jaws following guided implant surgery protocol. Post-surgery CBCT scans were made for each jaw, and the deviations between the planned and actual implant positions were measured. Deviation of implant position was compared between maxilla and mandible, and between cases with and without anchor pins using independent t-test. Results: Nine patients (3 males and 6 females) with 12 edentulous jaws were recruited. The mean age of patients was 59.2 ± 13.9 years old. All 44 implants was placed without complication and survived, the mean three dimensional linear deviation of implant position between virtual planning and actual placement was 1.53 ± 0.48 mm at the implant neck and 1.58 ± 0.49 mm at the apex. The angular deviation was 3.96 ± 3.05 degrees. No significant difference was found in the deviation of implant position between maxilla and mandible (P = 0.28 at neck, 0.08 at apex), nor between cases with and without anchor pins (P = 0.87 at neck, 0.06 at apex). Conclusions: The guides fabricated using the CNC milling technique provided comparable accuracy as those fabricated by Stereolithography. The displacement of the guides on edentulous arch might be the main contributing factor of deviation. Trial registration: Chinese Clinical Trial Registry, ChiCTR-ONC-17014159 (July 26, 2017).