Anton Kozmai

Dr. Anton Kozmai


Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 October 2021 in Membranes
Verified
Journal Article
Open access
PDF file
Lasaad DAMMAKLasaad DAMMAK
Lasaad DAMMAK
JFJulie Fouilloux
Julie Fouilloux
MBMyriam Bdiri
Myriam Bdiri
CLCHRISTIAN LARCHET
CHRISTIAN LARCHET
EREstelle Renard
Estelle Renard
Natalia PismenskayaNatalia Pismenskaya
Natalia Pismenskaya
Electrodialysis (ED) was first established for water desalination and is still highly recommended in this field for its high water recovery, long lifetime and acceptable electricity consumption. Today, thanks to technological progress in ED processes and the emergence of new ion-exchange membranes (IEMs), ED has been extended to many other applications in the food industry. This expansion of uses has also generated several problems such as IEMs’ lifetime limitation due to different ageing phenomena (because of organic and/or mineral compounds). The current commercial IEMs show excellent performance in ED processes; however, organic foulants such as proteins, surfactants, polyphenols or other natural organic matters can adhere on their surface (especially when using anion-exchange membranes: AEMs) forming a colloid layer or can infiltrate the membrane matrix, which leads to the increase in electrical resistance, resulting in higher energy consumption, lower water recovery, loss of membrane permselectivity and current efficiency as well as lifetime limitation. If these aspects are not sufficiently controlled and mastered, the use and the efficiency of ED processes will be limited since, it will no longer be competitive or profitable compared to other separation methods. In this work we reviewed a significant amount of recent scientific publications, research and reviews studying the phenomena of IEM fouling during the ED process in food industry with a special focus on the last decade. We first classified the different types of fouling according to the most commonly used classifications. Then, the fouling effects, the characterization methods and techniques as well as the different fouling mechanisms and interactions as well as their influence on IEM matrix and fixed groups were presented, analyzed, discussed and illustrated.

25 October 2021 in Membranes
Verified
Journal Article
Open access
PDF file
Natalia PismenskayaNatalia Pismenskaya
Natalia Pismenskaya
MBMyriam Bdiri
Myriam Bdiri
VSVeronika Sarapulova
Veronika Sarapulova
AKAnton Kozmai
Anton Kozmai
JFJulie Fouilloux
Julie Fouilloux
Lasaad DAMMAKLasaad DAMMAK
Lasaad DAMMAK
Ion-exchange membranes (IEMs) are increasingly used in dialysis and electrodialysis processes for the extraction, fractionation and concentration of valuable components, as well as reagent-free control of liquid media pH in the food industry. Fouling of IEMs is specific compared to that observed in the case of reverse or direct osmosis, ultrafiltration, microfiltration, and other membrane processes. This specificity is determined by the high concentration of fixed groups in IEMs, as well as by the phenomena inherent only in electromembrane processes, i.e., induced by an electric field. This review analyzes modern scientific publications on the effect of foulants (mainly typical for the dairy, wine and fruit juice industries) on the structural, transport, mass transfer, and electrochemical characteristics of cation-exchange and anion-exchange membranes. The relationship between the nature of the foulant and the structure, physicochemical, transport properties and behavior of ion-exchange membranes in an electric field is analyzed using experimental data (ion exchange capacity, water content, conductivity, diffusion permeability, limiting current density, water splitting, electroconvection, etc.) and modern mathematical models. The implications of traditional chemical cleaning are taken into account in this analysis and modern non-destructive membrane cleaning methods are discussed. Finally, challenges for the near future were identified.

22 December 2020 in Membranes
Verified
Journal Article
Open access
PDF file
AKAnton Kozmai
Anton Kozmai
VSVeronika Sarapulova
Veronika Sarapulova
MSMikhail Sharafan
Mikhail Sharafan
KMKarina Melkonian
Karina Melkonian
TRTatiana Rusinova
Tatiana Rusinova
Victor NikonenkoVictor Nikonenko
Victor Nikonenko
The broad possibilities of electrochemical impedance spectroscopy for assessing the capacitance of interphase boundaries; the resistance and thickness of the foulant layer were shown by the example of AMX-Sb membrane contacted with red wine from one side and 0.02 M sodium chloride solution from the other side. This enabled us to determine to what extent foulants affect the electrical resistance of ion-exchange membranes, the ohmic resistance and the thickness of diffusion layers, the intensity of water splitting, and the electroconvection in under- and over-limiting current modes. It was established that short-term (10 h) contact of the AMX-Sb membrane with wine reduces the water-splitting due to the screening of fixed groups on the membrane surface by wine components. On the contrary, biofouling, which develops upon a longer membrane operation, enhances water splitting, due to the formation of a bipolar structure on the AMX-Sb surface. This bipolar structure is composed of a positively charged surface of anion-exchange membrane and negatively charged outer membranes of microorganisms. Using optical microscopy and microbiological analysis, it was found that more intense biofouling is observed on the AMX-Sb surface, that has not been in contacted with wine.

1 December 2015 in Desalination and Water Treatment
Verified
Journal Article
Open access
Semyon A. MareevSemyon A. Mareev
Semyon A. Mareev
AKAnton Kozmai
Anton Kozmai
Victor NikonenkoVictor Nikonenko
Victor Nikonenko
EBE. Belashova
E. Belashova
GPG. Pourcelly
G. Pourcelly
PSPhilippe Sistat
Philippe Sistat
It is known that the behavior of a membrane with homogeneous and heterogeneous surface under the same current density is different. In order to find out this difference, a two-dimensional non-stationary model of mass transfer through electrically inhomogeneous surface of ion-exchange membrane under direct current is proposed. In this paper, the general formulation of the boundary conditions at the conductive sections has the form of the integral function of the local current density. The problem was solved by applying an electric current stream function, which is quite similar to the stream function in hydrodynamics. For the first time, it is proved that the distribution of current lines over the conductive sections of the membrane is not uniform. It is shown experimentally and theoretically that the shape of chronopotentiograms and electrochemical impedance spectra changes with changing conductive portion of the ion-exchange membrane surface.

3 September 2019 in Membranes
Verified
Journal Article
Open access
PDF file
MBMyriam Bdiri
Myriam Bdiri
ABAsma Bensghaier
Asma Bensghaier
LCLobna Chaabane
Lobna Chaabane
AKAnton Kozmai
Anton Kozmai
LBLassaad Baklouti
Lassaad Baklouti
CLCHRISTIAN LARCHET
CHRISTIAN LARCHET
The use of enzymatic agents as biological solutions for cleaning ion-exchange membranes fouled by organic compounds during electrodialysis (ED) treatments in the food industry could be an interesting alternative to chemical cleanings implemented at an industrial scale. This paper is focused on testing the cleaning efficiency of three enzyme classes (β-glucanase, protease, and polyphenol oxidase) chosen for their specific actions on polysaccharides, proteins, and phenolic compounds, respectively, fouled on a homogeneous cation-exchange membrane (referred CMX-Sb) used for tartaric stabilization of red wine by ED in industry. First, enzymatic cleaning tests were performed using each enzyme solution separately with two different concentrations (0.1 and 1.0 g/L) at different incubation temperatures (30, 35, 40, 45, and 50 °C). The evolution of membrane parameters (electrical conductivity, ion-exchange capacity, and contact angle) was determined to estimate the efficiency of the membrane′s principal action as well as its side activities. Based on these tests, we determined the optimal operating conditions for optimal recovery of the studied characteristics. Then, cleaning with three successive enzyme solutions or the use of two enzymes simultaneously in an enzyme mixture were tested taking into account the optimal conditions of their enzymatic activity (concentration, temperatures, and pH). This study led to significant results, indicating effective external and internal cleaning by the studied enzymes (a recovery of at least 25% of the electrical conductivity, 14% of the ion-exchange capacity, and 12% of the contact angle), and demonstrated the presence of possible enzyme combinations for the enhancement of the global cleaning efficiency or reducing cleaning durations. These results prove, for the first time, the applicability of enzymatic cleanings to membranes, the inertia of their action towards polymer matrix to the extent that the choice of enzymes is specific to the fouling substrates.

10 December 2019 in Membranes
Verified
Journal Article
Open access
PDF file
AKAnton Kozmai
Anton Kozmai
EGElena Goleva
Elena Goleva
VVVera Vasil'eva
Vera Vasil'eva
Victor NikonenkoVictor Nikonenko
Victor Nikonenko
Natalia PismenskayaNatalia Pismenskaya
Natalia Pismenskaya
A simple non-steady state mathematical model is proposed for the process of purification of an amino acid solution from mineral salts by the method of neutralization dialysis (ND), carried out in a circulating hydrodynamic mode. The model takes into account the characteristics of membranes (thickness, exchange capacity and electric conductivity) and solution (concentration and components nature) as well as the solution flow rate in dialyzer compartments. In contrast to the known models, the new model considers a local change in the ion concentration in membranes and the adjacent diffusion layers. In addition, the model takes into consideration the ability of the amino acid to enter the protonation/deprotonation reactions. A comparison of the results of simulations with experimental data allows us to conclude that the model adequately describes the ND of a strong electrolyte (NaCl) and amino acid (phenylalanine) mixture solutions in the case where the diffusion ability of amino acids in membranes is much less, than mineral salts. An example shows the application of the model to predict the fluxes of salt ions through ion exchange membranes as well as pH of the desalination solution at a higher than in experiments flow rate of solutions in ND dialyzer compartments.