Veronika Sarapulova

Mrs. Veronika Sarapulova

orcid

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 2017 in Journal of Membrane Science
Verified
Journal Article
Closed access
KKKsenia Kirichenko
Ksenia Kirichenko
VSVeronika Sarapulova
Veronika Sarapulova
KSK.G. Sabbatovskiy
K.G. Sabbatovskiy
VSV.D. Sobolev
V.D. Sobolev
NPN.D. Pismenskaya
N.D. Pismenskaya
Victor NikonenkoVictor Nikonenko
Victor Nikonenko

16 October 2021 in Membranes
Verified
Journal Article
Open access
PDF file
Lasaad DAMMAKLasaad DAMMAK
Lasaad DAMMAK
JFJulie Fouilloux
Julie Fouilloux
MBMyriam Bdiri
Myriam Bdiri
CLCHRISTIAN LARCHET
CHRISTIAN LARCHET
EREstelle Renard
Estelle Renard
Natalia PismenskayaNatalia Pismenskaya
Natalia Pismenskaya
Electrodialysis (ED) was first established for water desalination and is still highly recommended in this field for its high water recovery, long lifetime and acceptable electricity consumption. Today, thanks to technological progress in ED processes and the emergence of new ion-exchange membranes (IEMs), ED has been extended to many other applications in the food industry. This expansion of uses has also generated several problems such as IEMs’ lifetime limitation due to different ageing phenomena (because of organic and/or mineral compounds). The current commercial IEMs show excellent performance in ED processes; however, organic foulants such as proteins, surfactants, polyphenols or other natural organic matters can adhere on their surface (especially when using anion-exchange membranes: AEMs) forming a colloid layer or can infiltrate the membrane matrix, which leads to the increase in electrical resistance, resulting in higher energy consumption, lower water recovery, loss of membrane permselectivity and current efficiency as well as lifetime limitation. If these aspects are not sufficiently controlled and mastered, the use and the efficiency of ED processes will be limited since, it will no longer be competitive or profitable compared to other separation methods. In this work we reviewed a significant amount of recent scientific publications, research and reviews studying the phenomena of IEM fouling during the ED process in food industry with a special focus on the last decade. We first classified the different types of fouling according to the most commonly used classifications. Then, the fouling effects, the characterization methods and techniques as well as the different fouling mechanisms and interactions as well as their influence on IEM matrix and fixed groups were presented, analyzed, discussed and illustrated.

14 July 2019 in Membranes
Verified
Journal Article
Open access
PDF file
VSVeronika Sarapulova
Veronika Sarapulova
ISInna Shkorkina
Inna Shkorkina
Semyon A. MareevSemyon A. Mareev
Semyon A. Mareev
Natalia PismenskayaNatalia Pismenskaya
Natalia Pismenskaya
NKNatalia Kononenko
Natalia Kononenko
Victor NikonenkoVictor Nikonenko
Victor Nikonenko
Ion-exchange membranes (IEMs) find more and more applications; the success of an application depends on the properties of the membranes selected for its realization. For the first time, the results of a comprehensive characterization of the transport properties of IEMs from three manufactures (Astom, Japan; Shchekinoazot, Russia; and Fujifilm, The Netherlands) are reported. Our own and literature data are presented and analyzed using the microheterogeneous model. Homogeneous Neosepta AMX and CMX (Astom), heterogeneous MA-41 and MK-40 (Shchekinoazot), and AEM Type-I, AEM Type-II, AEM Type-X, as well as CEM Type-I, CEM Type-II, and CEM Type-X produced by the electrospinning method (Fujifim) were studied. The concentration dependencies of the conductivity, diffusion permeability, as well as the real and apparent ion transport numbers in these membranes were measured. The counterion transport number characterizing the membrane permselectivity increases in the following order: CEM Type-I ≅ MA-41 < AEM Type-I < MK-40 < CMX ≅ CEM Type-II ≅ CEM Type-X ≅ AEM Type-II < AMX < AEM Type-X. It is shown that the properties of the AEM Type-I and CEM Type-I membranes are close to those of the heterogeneous MA-41 and MK-40 membranes, while the properties of Fujifilm Type-II and Type-X membranes are close to those of the homogeneous AMX and CMX membranes. This difference is related to the fact that the Type-I membranes have a relatively high parameter f2, the volume fraction of the electroneutral solution filling the intergel spaces. This high value is apparently due to the open-ended pores, formed by the reinforcing fabric filaments of the Type-I membranes, which protrude above the surface of these membranes.

1 April 2015 in Journal of Membrane Science
Verified
Journal Article
Closed access
VSVeronika Sarapulova
Veronika Sarapulova
ENE. Nevakshenova
E. Nevakshenova
NPN. Pismenskaya
N. Pismenskaya
LDL. Dammak
L. Dammak
Victor NikonenkoVictor Nikonenko
Victor Nikonenko

Verified
Journal Article
Open access
PDF file
Natalia PismenskayaNatalia Pismenskaya
Natalia Pismenskaya
VSVeronika Sarapulova
Veronika Sarapulova
AKAnastasiia V. Klevtsova
Anastasiia V. Klevtsova
SMSergey Mikhaylin
Sergey Mikhaylin
Laurent BazinetLaurent Bazinet
Laurent Bazinet
This study examines the mechanisms of adsorption of anthocyanins from model aqueous solutions at pH values of 3, 6, and 9 by ion-exchange resins making the main component of heterogeneous ion-exchange membranes. This is the first report demonstrating that the pH of the internal solution of a KU-2-8 aromatic cation-exchange resin is 2-3 units lower than the pH of the external bathing anthocyanin-containing solution, and the pH of the internal solution of some anion-exchange resins with an aromatic (AV-17-8, AV-17-2P) or aliphatic (EDE-10P) matrix is 2–4 units higher than the pH of the external solution. This pH shift is caused by the Donnan exclusion of hydroxyl ions (in the KU-2-8 resin) or protons (in the AV-17-8, AV-17-2P, and EDE-10P resins). The most significant pH shift is observed for the EDE-10P resin, which has the highest ion-exchange capacity causing the highest Donnan exclusion. Due to the pH shift, the electric charge of anthocyanin inside an ion-exchange resin differs from its charge in the external solution. At pH 6, the external solution contains uncharged anthocyanin molecules. However, in the AV-17-8 and AV-17-2P resins, the anthocyanins are present as singly charged anions, while in the EDE-10P resin, they are in the form of doubly charged anions. Due to the electrostatic interactions of these anions with the positively charged fixed groups of anion-exchange resins, the adsorption capacities of AV-17-8, AV-17-2P, and EDE-10P were higher than expected. It was established that the electrostatic interactions of anthocyanins with the charged fixed groups increase the adsorption capacity of the aromatic resin by a factor of 1.8–2.5 compared to the adsorption caused by the π–π (stacking) interactions. These results provide new insights into the fouling mechanism of ion-exchange materials by polyphenols; they can help develop strategies for membrane cleaning and for extracting anthocyanins from juices and wine using ion-exchange resins and membranes.

25 October 2021 in Membranes
Verified
Journal Article
Open access
PDF file
Natalia PismenskayaNatalia Pismenskaya
Natalia Pismenskaya
MBMyriam Bdiri
Myriam Bdiri
VSVeronika Sarapulova
Veronika Sarapulova
AKAnton Kozmai
Anton Kozmai
JFJulie Fouilloux
Julie Fouilloux
Lasaad DAMMAKLasaad DAMMAK
Lasaad DAMMAK
Ion-exchange membranes (IEMs) are increasingly used in dialysis and electrodialysis processes for the extraction, fractionation and concentration of valuable components, as well as reagent-free control of liquid media pH in the food industry. Fouling of IEMs is specific compared to that observed in the case of reverse or direct osmosis, ultrafiltration, microfiltration, and other membrane processes. This specificity is determined by the high concentration of fixed groups in IEMs, as well as by the phenomena inherent only in electromembrane processes, i.e., induced by an electric field. This review analyzes modern scientific publications on the effect of foulants (mainly typical for the dairy, wine and fruit juice industries) on the structural, transport, mass transfer, and electrochemical characteristics of cation-exchange and anion-exchange membranes. The relationship between the nature of the foulant and the structure, physicochemical, transport properties and behavior of ion-exchange membranes in an electric field is analyzed using experimental data (ion exchange capacity, water content, conductivity, diffusion permeability, limiting current density, water splitting, electroconvection, etc.) and modern mathematical models. The implications of traditional chemical cleaning are taken into account in this analysis and modern non-destructive membrane cleaning methods are discussed. Finally, challenges for the near future were identified.