David Merino

Dr. David Merino

orcid

Research Focus & Metrics

Academic Career Length

22Years (2005-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 July 2011 in Biomedical Optics Express
Verified
Journal Article
Open access
PDF file
DMDavid Merino
David Merino
JDJacque L. Duncan
Jacque L. Duncan
PTPavan Tiruveedhula
Pavan Tiruveedhula
ARAustin Roorda
Austin Roorda
We demonstrate the capability of a new generation adaptive optics scanning laser ophthalmoscope (AOSLO) to resolve cones and rods in normal subjects, and confirm our findings by comparing cone and rod spacing with published histology measurements. Cone and rod spacing measurements are also performed on AOSLO images from two different diseased eyes, one affected by achromatopsia and the other by acute zonal occult outer retinopathy (AZOOR). The potential of AOSLO technology in the study of these and other retinal diseases is illustrated.


1 January 2006 in Optics Express
Verified
Journal Article
Closed access
PDF file
DMDavid Merino
David Merino
CDChris Dainty
Chris Dainty
Adrian BraduAdrian Bradu
Adrian Bradu
Adrian PodoleanuAdrian Podoleanu
Adrian Podoleanu
A novel combination of adaptive optics with a simultaneous en-face OCT/SLO system for high resolution imaging of the in-vivo human retina is presented. Pairs of retinal images are shown and performance of the system is evaluated with and without dynamic wavefront correction. The adaptive optics closed loop system operates at a frame rate of 9 Hz and incorporates a Shack-Hartmann wavefront sensor based on a highly sensitive Andor camera and a 37 actuator OKO membrane deformable mirror to correct for ocular aberrations. The system produces C-scan pairs of images at a frame rate of 2 Hz. The correction of aberrations produced by the adaptive optics closed-loop system increased the signal-to-noise ratio in images obtained from volunteer eyes by up to 6 dB in the OCT channel and up to 9 dB in the SLO channel. A slight improvement in the lateral resolution was also obtained, from 6.5 μm before to 5 μm after closing the adaptive optics loop.

15 November 2010 in Optics Express
Verified
Journal Article
Open access
PDF file
NPNicole M. Putnam
Nicole M. Putnam
DHDaniel X. Hammer
Daniel X. Hammer
YZYuhua Zhang
Yuhua Zhang
DMDavid Merino
David Merino
ARAustin Roorda
Austin Roorda
Optics InfoBase is the Optical Society's online library for flagship journals, partnered and copublished journals, and recent proceedings from OSA conferences.

1 April 2012 in American Journal of Ophthalmology
Verified
Journal Article
Closed access
MMMarianna Mkrtchyan
Marianna Mkrtchyan
BLBrandon J. Lujan
Brandon J. Lujan
DMDavid Merino
David Merino
CTCharles E. Thirkill
Charles E. Thirkill
ARAustin Roorda
Austin Roorda
JDJacque L. Duncan
Jacque L. Duncan

1 April 2016 in Clinical Ophthalmology
Verified
Journal Article
Open access
PDF file
DMDavid Merino
David Merino
PLPablo Loza-Alvarez
Pablo Loza-Alvarez
Adaptive optics (AO) retinal imaging has become very popular in the past few years, especially within the ophthalmic research community. Several different retinal techniques, such as fundus imaging cameras or optical coherence tomography systems, have been coupled with AO in order to produce impressive images showing individual cell mosaics over different layers of the in vivo human retina. The combination of AO with scanning laser ophthalmoscopy has been extensively used to generate impressive images of the human retina with unprecedented resolution, showing individual photoreceptor cells, retinal pigment epithelium cells, as well as microscopic capillary vessels, or the nerve fiber layer. Over the past few years, the technique has evolved to develop several different applications not only in the clinic but also in different animal models, thanks to technological developments in the field. These developments have specific applications to different fields of investigation, which are not limited to the study of retinal diseases but also to the understanding of the retinal function and vision science. This review is an attempt to summarize these developments in an understandable and brief manner in order to guide the reader into the possibilities that AO scanning laser ophthalmoscopy offers, as well as its limitations, which should be taken into account when planning on using it.