Adrian Bradu

Dr. Adrian Bradu

Applied Optics Group, University of Kent, Canterbury CT2 7NZ, UK
orcid

Research Focus & Metrics

Academic Career Length

26Years (2001-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 May 2013 in Journal of the Association for Research in Otolaryngology
Verified
Journal Article
Closed access
PDF file
SJSam Van der Jeught
Sam Van der Jeught
JDJoris Dirckx
Joris Dirckx
JAJohan R. M. Aerts
Johan R. M. Aerts
Adrian BraduAdrian Bradu
Adrian Bradu
Adrian PodoleanuAdrian Podoleanu
Adrian Podoleanu
JBJan A. N. Buytaert
Jan A. N. Buytaert

1 January 2006 in Optics Express
Verified
Journal Article
Closed access
PDF file
DMDavid Merino
David Merino
CDChris Dainty
Chris Dainty
Adrian BraduAdrian Bradu
Adrian Bradu
Adrian PodoleanuAdrian Podoleanu
Adrian Podoleanu
A novel combination of adaptive optics with a simultaneous en-face OCT/SLO system for high resolution imaging of the in-vivo human retina is presented. Pairs of retinal images are shown and performance of the system is evaluated with and without dynamic wavefront correction. The adaptive optics closed loop system operates at a frame rate of 9 Hz and incorporates a Shack-Hartmann wavefront sensor based on a highly sensitive Andor camera and a 37 actuator OKO membrane deformable mirror to correct for ocular aberrations. The system produces C-scan pairs of images at a frame rate of 2 Hz. The correction of aberrations produced by the adaptive optics closed-loop system increased the signal-to-noise ratio in images obtained from volunteer eyes by up to 6 dB in the OCT channel and up to 9 dB in the SLO channel. A slight improvement in the lateral resolution was also obtained, from 6.5 μm before to 5 μm after closing the adaptive optics loop.

7 August 2013 in Optics Express
Verified
Journal Article
Closed access
PDF file
Adrian PodoleanuAdrian Podoleanu
Adrian Podoleanu
Adrian BraduAdrian Bradu
Adrian Bradu
Optics InfoBase is the Optical Society's online library for flagship journals, partnered and copublished journals, and recent proceedings from OSA conferences.

28 October 2020 in Materials
Verified
Journal Article
Open access
PDF file
Ralph-Alexandru ErdelyiRalph-Alexandru Erdelyi
Ralph-Alexandru Erdelyi
Virgil-Florin DumaVirgil-Florin Duma
Virgil-Florin Duma
Cosmin SinescuCosmin Sinescu
Cosmin Sinescu
GDGeorge Mihai Dobre
George Mihai Dobre
Adrian BraduAdrian Bradu
Adrian Bradu
Adrian PodoleanuAdrian Podoleanu
Adrian Podoleanu
A correct diagnosis in dental medicine is typically provided only after clinical and radiological evaluations. They are also required for treatment assessments. The aim of this study is to establish the boundaries from which a modern, although established, imaging technique, Optical Coherence Tomography (OCT), is more suitable than the common X-ray radiography to assess dental issues and treatments. The most common methods for daily-basis clinical imaging are utilized in this study for extracted teeth (but also for other dental samples and materials), i.e., panoramic, intraoral radiography, and three-dimensional (3D) cone beam computed tomography (CBCT). The advantages of using OCT as an imaging method in dentistry are discussed, with a focus on its superior image resolution. Drawbacks related to its limited penetration depth and Field-of-View (FOV) are pointed out. High-quality radiological investigations are performed, measurements are done, and data collected. The same teeth and samples are also imaged (mostly) with an in-house developed Swept Source (SS)-OCT system, Master-Slave enhanced. Some of the OCT investigations employed two other in-house developed OCT systems, Spectral Domain (SD) and Time Domain (TD). Dedicated toolbars from Romexis software (Planmeca, Helsinki, Finland) are used to perform measurements using both radiography and OCT. Clinical conclusions are drawn from the investigations. Upsides and downsides of the two medical imaging techniques are concluded for each type of considered diagnosis. For treatment assessments, it is concluded that OCT is more appropriate than radiography in all applications, except bone-related investigations and periodontitis that demand data from higher-penetration depths than possible with the current level of OCT technology.

8 August 2014 in Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine
Verified
Journal Article
Open access
DDDorin Demian
Dorin Demian
Virgil-Florin DumaVirgil-Florin Duma
Virgil-Florin Duma
CSCosmin Sinescu
Cosmin Sinescu
Meda-Lavinia NegrutiuMeda-Lavinia Negrutiu
Meda-Lavinia Negrutiu
RCRamona Cernat
Ramona Cernat
Adrian PodoleanuAdrian Podoleanu
Adrian Podoleanu
Three simple and low-cost configurations of handheld scanning probes for optical coherence tomography have been developed. Their design and testing for dentistry applications are presented. The first two configurations were built exclusively from available off-the-shelf optomechanical components, which, to the best of our knowledge, are the first designs of this type. The third configuration includes these components in an optimized and ergonomic probe. All the designs are presented in detail to allow for their duplication in any laboratory with a minimum effort, for applications that range from educational to high-end clinical investigations. Requirements that have to be fulfilled to achieve configurations which are reliable, ergonomic—for clinical environments, and easy to build are presented. While a range of applications is possible for the prototypes developed, in this study the handheld probes are tested ex vivo with a spectral domain optical coherence tomography system built in-house, for dental constructs. A previous testing with a swept source optical coherence tomography system has also been performed both in vivo and ex vivo for ear, nose, and throat—in a medical environment. The applications use the capability of optical coherence tomography to achieve real-time, high-resolution, non-contact, and non-destructive interferometric investigations with micrometer resolutions and millimeter penetration depth inside the sample. In this study, testing the quality of the material of one of the most used types of dental prosthesis, metalo-ceramic is thus demonstrated.

1 January 2008 in Journal of Biomedical Optics
Verified
Journal Article
Open access
PDF file
CSCosmin Sinescu
Cosmin Sinescu
Meda-Lavinia NegrutiuMeda-Lavinia Negrutiu
Meda-Lavinia Negrutiu
CTCarmen Todea
Carmen Todea
CBCosmin Balabuc
Cosmin Balabuc
LFLaura Filip
Laura Filip
Adrian PodoleanuAdrian Podoleanu
Adrian Podoleanu
The present study evaluates the potential of en-face optical coherence tomography (OCT) as a possible noninvasive high resolution method for supplying necessary information on the material defects of dental prostheses and microleakage at prosthetic interfaces. Teeth are also imaged after several treatment methods to asses material defects and microleakage at the tooth-filling interface, and the presence or absence of apical microleakage, as well as to evaluate the quality of bracket bonding on dental hard tissue. C-scan and B-scan OCT images as well as confocal images are acquired from a large range of samples. Gaps between the dental interfaces and material defects are clearly exposed.