Krishna Mandal

Prof. Krishna Mandal

orcid

Research Focus & Metrics

Academic Career Length

22Years (2005-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 February 2020 in Micromachines
Verified
Journal Article
Open access
PDF file
KMKrishna Mandal
Krishna Mandal
JKJoshua W. Kleppinger
Joshua W. Kleppinger
SCSandeep Chaudhuri
Sandeep Chaudhuri
Advances towards achieving the goal of miniature 4H-SiC based radiation detectors for harsh environment application have been studied extensively and reviewed in this article. The miniaturized devices were developed at the University of South Carolina (UofSC) on 8 × 8 mm 4H-SiC epitaxial layer wafers with an active area of ≈11 mm2. The thicknesses of the actual epitaxial layers were either 20 or 50 µm. The article reviews the investigation of defect levels in 4H-SiC epilayers and radiation detection properties of Schottky barrier devices (SBDs) fabricated in our laboratories at UofSC. Our studies led to the development of miniature SBDs with superior quality radiation detectors with highest reported energy resolution for alpha particles. The primary findings of this article shed light on defect identification in 4H-SiC epilayers and their correlation with the radiation detection properties.

25 June 2021 in Journal of Applied Physics
Verified
Journal Article
Closed access
PDF file
JKJoshua W. Kleppinger
Joshua W. Kleppinger
SCSandeep Chaudhuri
Sandeep Chaudhuri
OKOmerFaruk Karadavut
OmerFaruk Karadavut
KMKrishna Mandal
Krishna Mandal
Advances in the growth processes of 4H-SiC epitaxial layers have led to the continued expansion of epilayer thickness, allowing for the detection of more penetrative radioactive particles. We report the fabrication and characterization of high-resolution Schottky barrier radiation detectors on 250 μm thick n-type 4H-SiC epitaxial layers, the highest reported thickness to date. Several 8 × 8 mm2 detectors were fabricated from a diced 100 mm diameter 4H-SiC epitaxial wafer grown on a conductive 4H-SiC substrate with a mean micropipe density of 0.11 cm−2. From the Mott–Schottky plots, the effective doping concentration was found to be in the range (0.95–1.85) × 1014 cm−3, implying that full depletion could be achieved at ∼5.7 kV (0.5 MV/cm at the interface). The current-voltage characteristics demonstrated consistently low leakage current densities of 1–3 nA/cm2 at a reverse bias of −800 V. This resulted in the pulse-height spectra generated using a 241Am alpha source (5486 keV) manifesting an energy resolution of less than 0.5% full width at half maximum (FWHM) for all the detectors at −200 V. The charge collection efficiencies (CCEs) were measured to be 98–99% with no discernable correlation to the energy resolution. A drift-diffusion model fit to the variation of CCE as a function of bias voltage, revealed a minority carrier diffusion length of ∼10 μm. Deep level transient spectroscopy measurements on the best resolution detector revealed that the excellent performance was the result of having ultralow concentrations of the order of 1011 cm−3 lifetime limiting defects—Z1/2 and EH6/7.

17 January 2017 in Journal of Applied Physics
Verified
Journal Article
Closed access
PSPiyas Samanta
Piyas Samanta
KMKrishna Mandal
Krishna Mandal
The conduction mechanism(s) of gate leakage current JG through thermally grown silicon dioxide (SiO2) films on the silicon (Si) face of n-type 4H-silicon carbide (4H-SiC) has been studied in detail under positive gate bias. It was observed that at an oxide field above 5 MV/cm, the leakage current measured up to 303 °C can be explained by Fowler-Nordheim (FN) tunneling of electrons from the accumulated n-4H-SiC and Poole-Frenkel (PF) emission of trapped electrons from the localized neutral traps located at ≈ 2.5 eV below the SiO2 conduction band. However, the PF emission current IPF dominates the FN electron tunneling current IFN at oxide electric fields Eox between 5 and 10 MV/cm and in the temperature ranging from 31 to 303 °C. In addition, we have presented a comprehensive analysis of injection of holes and their subsequent trapping into as-grown oxide traps eventually leading to time-dependent dielectric breakdown during electron injection under positive bias temperature stress (PBTS) in n-4H-SiC metal-oxide-silicon carbide structures. Holes were generated in the heavily doped n-type polycrystalline silicon (n+-polySi) gate (anode) as well as in the oxide bulk via band-to-band ionization by the hot-electrons depending on their energy and SiO2 film thickness at Eox between 6 and 10 MV/cm (prior to the intrinsic oxide breakdown field). Transport of hot electrons emitted via both FN and PF mechanisms was taken into account. On the premise of the hole-induced oxide breakdown model, the time- and charge-to-breakdown (tBD and QBD ) of 8.5 to 47 nm-thick SiO2 films on n-4H-SiC were estimated at a wide range of temperatures. tBD follows the Arrhenius law with activation energies varying inversely with initial applied constant field Eox supporting the reciprocal field (1/E ) model of breakdown irrespective of SiO2 film thicknesses. We obtained an excellent margin (6.66 to 6.33 MV/cm at 31 °C and 5.11 to 4.55 MV/cm at 303 °C) of normal operating field for a 10-year projected lifetime of 8.5 to 47 nm-thick SiO2 films on n-4H-SiC under positive bias on the n+-polySi gate. Furthermore, the projected maximum operating oxide field was little higher in metal gate devices compared to n+-polySi gate devices having an identically thick thermal SiO2 films under PBTS.

17 April 2023 in IEEE Transactions on Nuclear Science
Verified
Journal Article
Closed access
KMKrishna Mandal
Krishna Mandal
SCSandeep Chaudhuri
Sandeep Chaudhuri
FRFrank H. Ruddy
Frank H. Ruddy
Silicon Carbide (SiC) semiconductor radiation detectors were first demonstrated in 1957, however, meaningful progress was delayed until the mid-1990s when high-quality epitaxially-grown SiC became available. Rapid progress ensued, and detection of alpha particles, gamma and X-rays, protons, fission fragments, heavy ions, beta particles, minimum-ionizing particles, and neutrons were all demonstrated. In the case of alpha-particle detection and spectrometry, the obtainable energy resolution is dependent on the design characteristics of the SiC detector as well as on the material and electronic properties of the SiC material. In this paper, we review the history of SiC alpha-particle detector development as well as the factors affecting detector performance and the prospects for further improvements. Detector design factors, including active-volume and entrance-window effects, are discussed in detail. Materials and electronic factors that influence the quality of alpha-particle detection are also discussed. These factors include SiC lattice defects, charge-carrier mobility, charge trapping, and the energy required to produce an electron-hole pair. Since the first demonstration of alpha-particle spectrometry, SiC detectors have evolved to the point that an energy resolution of 0.29% (15.9 keV FWHM for 5485.7-keV 241 Am alpha particles) has been reported. This resolution is comparable to the best obtainable with Silicon alpha-particle detectors. The prospects for further improvements in alpha spectrometry with SiC detectors are also discussed.

26 June 2020 in Journal of Applied Physics
Verified
Journal Article
Open access
PDF file
SCSandeep Chaudhuri
Sandeep Chaudhuri
MSMohsin Sajjad
Mohsin Sajjad
JKJoshua W. Kleppinger
Joshua W. Kleppinger
KMKrishna Mandal
Krishna Mandal
CdxZn1−xTeySe1−y (CZTS) has emerged as a next-generation compound semiconductor for high energy gamma-ray detection. In the present study, we report for the first time the hole transport property measurements in CZTS based gamma-ray detectors in the planar configuration. Current–voltage measurements revealed a bulk resistivity of ∼5 × 108 Ω cm and the fabricated detectors produced well-resolved 5486 keV alpha particle peaks, for both electrons and holes drifting alike, when pulse-height spectra (PHS) were recorded using a 241Am radiation source. The PHS measurements were enabled to measure the charge transport properties for both the charge carriers. The mobility–lifetime product (μτ) for electrons and holes was calculated to be 6.4 × 10−4 cm2 V−1 and 8.5 × 10−5 cm2 V−1, respectively, using a single polarity Hecht plot regression method. The pre-amplifier pulses were also recorded and processed digitally to obtain electron and hole drift mobilities of 692 cm2 V−1 s−1 and 55 cm2 V−1 s−1, respectively, using a time-of-flight method. The measured transport properties indicated the hole lifetime to be greater than the electron lifetime by a factor of ∼1.5. Gamma-ray PHS were recorded using fabricated detectors that showed tailing of the 662 keV photopeak due to hole trapping effects. Depth dependent PHS were digitally generated from 2D biparametric plots to reveal the effects of hole trapping on the gamma PHS at different detector depths. Digital correction procedures were applied to generate well-resolved PHS with an energy resolution of ∼2% for 662 keV γ-rays.

16 July 2021 in Crystals
Verified
Journal Article
Open access
PDF file
SCSandeep Chaudhuri
Sandeep Chaudhuri
JKJoshua W. Kleppinger
Joshua W. Kleppinger
OKOmerfaruk Karadavut
Omerfaruk Karadavut
RNRitwik Nag
Ritwik Nag
KMKrishna Mandal
Krishna Mandal
The application of Cd0.9Zn0.1Te (CZT) single crystals, the primary choice for high-resolution, room-temperature compact gamma-ray detectors in the field of medical imaging and homeland security for the past three decades, is limited by the high cost of production and maintenance due to low detector grade crystal growth yield. The recent advent of its quaternary successor, Cd0.9Zn0.1Te1−ySey (CZTS), has exhibited remarkable crystal growth yield above 90% compared to that of ~33% for CZT. The inclusion of Se in appropriate stoichiometry in the CZT matrix is responsible for reducing the concentration of sub-grain boundary (SGB) networks which greatly enhances the compositional homogeneity and growth yield. SGB networks also host defect centers responsible for charge trapping, hence their reduced concentration ensures minimized charge trapping. Indeed, CZTS single crystals have shown remarkable improvement in electron charge transport properties and energy resolution over CZT detectors. However, our studies have found that the overall charge transport in CZTS is still limited by the hole trapping. In this article, we systematically review the advances in the CZTS growth techniques, its performance as room-temperature radiation detector, and the role of defects and their passivation studies needed to improve the performance of CZTS detectors further.