Advances towards achieving the goal of miniature 4H-SiC based radiation detectors for harsh environment application have been studied extensively and reviewed in this article. The miniaturized devices were developed at the University of South Carolina (UofSC) on 8 × 8 mm 4H-SiC epitaxial layer wafers with an active area of ≈11 mm2. The thicknesses of the actual epitaxial layers were either 20 or 50 µm. The article reviews the investigation of defect levels in 4H-SiC epilayers and radiation detection properties of Schottky barrier devices (SBDs) fabricated in our laboratories at UofSC. Our studies led to the development of miniature SBDs with superior quality radiation detectors with highest reported energy resolution for alpha particles. The primary findings of this article shed light on defect identification in 4H-SiC epilayers and their correlation with the radiation detection properties.
Advances in the growth processes of 4H-SiC epitaxial layers have led to the continued expansion of epilayer thickness, allowing for the detection of more penetrative radioactive particles. We report the fabrication and characterization of high-resolution Schottky barrier radiation detectors on 250 μm thick n-type 4H-SiC epitaxial layers, the highest reported thickness to date. Several 8 × 8 mm2 detectors were fabricated from a diced 100 mm diameter 4H-SiC epitaxial wafer grown on a conductive 4H-SiC substrate with a mean micropipe density of 0.11 cm−2. From the Mott–Schottky plots, the effective doping concentration was found to be in the range (0.95–1.85) × 1014 cm−3, implying that full depletion could be achieved at ∼5.7 kV (0.5 MV/cm at the interface). The current-voltage characteristics demonstrated consistently low leakage current densities of 1–3 nA/cm2 at a reverse bias of −800 V. This resulted in the pulse-height spectra generated using a 241Am alpha source (5486 keV) manifesting an energy resolution of less than 0.5% full width at half maximum (FWHM) for all the detectors at −200 V. The charge collection efficiencies (CCEs) were measured to be 98–99% with no discernable correlation to the energy resolution. A drift-diffusion model fit to the variation of CCE as a function of bias voltage, revealed a minority carrier diffusion length of ∼10 μm. Deep level transient spectroscopy measurements on the best resolution detector revealed that the excellent performance was the result of having ultralow concentrations of the order of 1011 cm−3 lifetime limiting defects—Z1/2 and EH6/7.
Defects present in ZnO nanocrystals prepared by a wet chemical method have been characterized by photoluminescence (PL) and positron annihilation spectroscopy (PAS) techniques. The as-prepared sample was heat treated at different temperatures to obtain nanocrystals in the size range of . X ray diffractograms confirmed the single-phase wurtzite structure formation. Photoluminescence measurements showed a strong violet band at , which has been identified as due to electronic transitions from the zinc interstitial defect level to the top of the valence band. A marked decrease in the intensity of the violet emission with increasing heat-treatment temperature has been observed, which is attributed to recombination of zinc interstitials with zinc vacancies. Positron annihilation spectroscopy has been employed to understand the dynamics of the vacancy-type defects and their annealing behavior. The observed variation of the defect related lifetime components with heat-treatment temperature has been successfully explained by using a three-state trapping model. The results of PL and PAS studies in the present case are found to be complementary to each other.
17 April 2023 in IEEE Transactions on Nuclear Science
Silicon Carbide (SiC) semiconductor radiation detectors were first demonstrated in 1957, however, meaningful progress was delayed until the mid-1990s when high-quality epitaxially-grown SiC became available. Rapid progress ensued, and detection of alpha particles, gamma and X-rays, protons, fission fragments, heavy ions, beta particles, minimum-ionizing particles, and neutrons were all demonstrated. In the case of alpha-particle detection and spectrometry, the obtainable energy resolution is dependent on the design characteristics of the SiC detector as well as on the material and electronic properties of the SiC material. In this paper, we review the history of SiC alpha-particle detector development as well as the factors affecting detector performance and the prospects for further improvements. Detector design factors, including active-volume and entrance-window effects, are discussed in detail. Materials and electronic factors that influence the quality of alpha-particle detection are also discussed. These factors include SiC lattice defects, charge-carrier mobility, charge trapping, and the energy required to produce an electron-hole pair. Since the first demonstration of alpha-particle spectrometry, SiC detectors have evolved to the point that an energy resolution of 0.29% (15.9 keV FWHM for 5485.7-keV 241 Am alpha particles) has been reported. This resolution is comparable to the best obtainable with Silicon alpha-particle detectors. The prospects for further improvements in alpha spectrometry with SiC detectors are also discussed.
CdxZn1−xTeySe1−y (CZTS) has emerged as a next-generation compound semiconductor for high energy gamma-ray detection. In the present study, we report for the first time the hole transport property measurements in CZTS based gamma-ray detectors in the planar configuration. Current–voltage measurements revealed a bulk resistivity of ∼5 × 108 Ω cm and the fabricated detectors produced well-resolved 5486 keV alpha particle peaks, for both electrons and holes drifting alike, when pulse-height spectra (PHS) were recorded using a 241Am radiation source. The PHS measurements were enabled to measure the charge transport properties for both the charge carriers. The mobility–lifetime product (μτ) for electrons and holes was calculated to be 6.4 × 10−4 cm2 V−1 and 8.5 × 10−5 cm2 V−1, respectively, using a single polarity Hecht plot regression method. The pre-amplifier pulses were also recorded and processed digitally to obtain electron and hole drift mobilities of 692 cm2 V−1 s−1 and 55 cm2 V−1 s−1, respectively, using a time-of-flight method. The measured transport properties indicated the hole lifetime to be greater than the electron lifetime by a factor of ∼1.5. Gamma-ray PHS were recorded using fabricated detectors that showed tailing of the 662 keV photopeak due to hole trapping effects. Depth dependent PHS were digitally generated from 2D biparametric plots to reveal the effects of hole trapping on the gamma PHS at different detector depths. Digital correction procedures were applied to generate well-resolved PHS with an energy resolution of ∼2% for 662 keV γ-rays.
The application of Cd0.9Zn0.1Te (CZT) single crystals, the primary choice for high-resolution, room-temperature compact gamma-ray detectors in the field of medical imaging and homeland security for the past three decades, is limited by the high cost of production and maintenance due to low detector grade crystal growth yield. The recent advent of its quaternary successor, Cd0.9Zn0.1Te1−ySey (CZTS), has exhibited remarkable crystal growth yield above 90% compared to that of ~33% for CZT. The inclusion of Se in appropriate stoichiometry in the CZT matrix is responsible for reducing the concentration of sub-grain boundary (SGB) networks which greatly enhances the compositional homogeneity and growth yield. SGB networks also host defect centers responsible for charge trapping, hence their reduced concentration ensures minimized charge trapping. Indeed, CZTS single crystals have shown remarkable improvement in electron charge transport properties and energy resolution over CZT detectors. However, our studies have found that the overall charge transport in CZTS is still limited by the hole trapping. In this article, we systematically review the advances in the CZTS growth techniques, its performance as room-temperature radiation detector, and the role of defects and their passivation studies needed to improve the performance of CZTS detectors further.