Ning Zhu

Dr. Ning Zhu

Biomedical Imaging and Therapy beamlines, Canadian Light Source Inc., 44 Innovation Boulevard, Saskatoon, SK, S7N 2V3, Canada

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 August 2023 in Nano Energy
Verified
Journal Article
Closed access
LYLeixin Yang
Leixin Yang
QMQianyi Ma
Qianyi Ma
YYYuelong Yin
Yuelong Yin
DLDan Luo
Dan Luo
YSYujie Shen
Yujie Shen
ZCZhongwei Chen
Zhongwei Chen

15 July 2024 in Journal of Synchrotron Radiation
Verified
Journal Article
Open access
PDF file
SGSergey Gasilov
Sergey Gasilov
AWAdam Webb
Adam Webb
APArash Panahifar
Arash Panahifar
NZNing Zhu
Ning Zhu
OMOmar Marinos
Omar Marinos
DCDean Chapman
Dean Chapman
The Biomedical Imaging and Therapy facility of the Canadian Light Source comprises two beamlines, which together cover a wide X-ray energy range from 13 keV up to 140 keV. The beamlines were designed with a focus on synchrotron applications in preclinical imaging and veterinary science as well as microbeam radiation therapy. While these remain a major part of the activities of both beamlines, a number of recent upgrades have enhanced the versatility and performance of the beamlines, particularly for high-resolution microtomography experiments. As a result, the user community has been quickly expanding to include researchers in advanced materials, batteries, fuel cells, agriculture, and environmental studies. This article summarizes the beam properties, describes the endstations together with the detector pool, and presents several application cases of the various X-ray imaging techniques available to users.

1 October 2017 in Hearing Research
Verified
Journal Article
Closed access
MEMai Elfarnawany
Mai Elfarnawany
SRSeyed Alireza Rohani
Seyed Alireza Rohani
SGSoroush Ghomashchi
Soroush Ghomashchi
DADaniel G. Allen
Daniel G. Allen
NZNing Zhu
Ning Zhu
HLHanif M. Ladak
Hanif M. Ladak

22 October 2010 in Biofabrication
Verified
Journal Article
Closed access
NZNing Zhu
Ning Zhu
MLM G Li
M G Li
YGY J Guan
Y J Guan
DSD J Schreyer
D J Schreyer
Xiongbiao ChenXiongbiao Chen
Xiongbiao Chen
Axon guidance is a crucial consideration in the design of tissue scaffolds used to promote nerve regeneration. Here we investigate the combined use of laminin (a putative axon adhesion and guidance molecule) and chitosan (a leading candidate base material for the construction of scaffolds) for promoting axon guidance in cultured adult dorsal root ganglion (DRG) neurons. Using a dispensing-based rapid prototyping (DBRP) technique, two-dimensional grid patterns were created by dispensing chitosan or laminin-blended chitosan substrate strands oriented in orthogonal directions. In vitro experiments illustrated DRG neurites on these patterns preferentially grew upon and followed the laminin-blended chitosan pathways. These results suggest that an orientation of neurite growth can be achieved in an artificially patterned substrate by creating selectively biofunctional pathways. The DBRP technique may provide improved strategies for the use of biofunctional pathways in the design of three-dimensional scaffolds for guidance of nerve repair.

29 November 2024 in Journal of the Mechanical Behavior of Biomedical Materials
Verified
Journal Article
Open access
NLNaitao Li
Naitao Li
XDXiaoman Duan
Xiaoman Duan
XDXiao Fan Ding
Xiao Fan Ding
NZNing Zhu
Ning Zhu
Xiongbiao ChenXiongbiao Chen
Xiongbiao Chen
Hydrogel-based scaffolds have been widely used in soft tissue regeneration due to their biocompatible and tissue-like environment for maintaining cellular functions and tissue regeneration. Understanding the mechanical properties and internal microstructure of hydrogel-based scaffold, once implanted, is imperative in tissue engineering applications and longitudinal studies. Notably, this has been challenging to date as various conventional characterization methods by, for example, mechanical testing (for mechanical properties) and microscope (for internal microstructure) are destructive as they require removing scaffolds from the implantation site and processing samples for characterization. Synchrotron radiation propagation-based imaging-computed tomography (SR-PBI-CT) is feasible and promising for non-destructive visualizing of hydrogel scaffolds. As inspired, this study aimed to perform a study on the characterization of mechanical properties and microstructure of hydrogel scaffolds based on the SR-PBI-CT. In this study, hydrogel biomaterial inks composed of 3% w/v alginate and 1% w/v gelatin were printed to form scaffolds, with some scaffolds being degraded over 3 days. Both degraded and undegraded scaffolds underwent compressive testing, with the strains being controlled at the preset values; meanwhile stresses within scaffolds were measuring, resulting the stress-strain curves. Concurrently, the scaffolds were also imaged and examined by SR-PBI-CT at Canadian Light Source (CLS). During the imaging process, the scaffolds were mechanically loaded, respectively, with the strains same as the ones in the aforementioned compressive testing, and at each strain, the scaffold was scanned with a pixel size of 13 μm. From the stress-strain curves obtained in the compression testing, the Young's modulus was evaluated to characterize the elastic behavior of scaffolds: with the range between around 5-25 kPa. From the images captured by SR-PBI-CT, the scaffolds microstructures were examined in terms of the strand cross-section area, pore size, and hydrogel volume. Further, from the SR-PBI-CT images, the stress within hydrogel of scaffolds were evaluated, showing the agreement with those obtained from compression testing. These results have illustrated that the mechanical properties and microstructures of scaffolds, ether being degraded or not, can be examined and characterized by the SR-PBI-CT imaging, in a non-destructive manner. This would represent a significant advance for facilitating longitudinal studies on the scaffolds once implanted in-vivo.

Verified
Journal Article
Open access
PDF file
DKDaisy (Jihyung) Ko
Daisy (Jihyung) Ko
TKTess Kelly
Tess Kelly
LTLacey Thompson
Lacey Thompson
JUJasmene K. Uppal
Jasmene K. Uppal
NRNasim Rostampour
Nasim Rostampour
JBJulia Boughner
Julia Boughner
For humans and other mammals to eat effectively, teeth must develop properly inside the jaw. Deciphering craniodental integration is central to explaining the timely formation of permanent molars, including third molars which are often impacted in humans, and to clarifying how teeth and jaws fit, function and evolve together. A factor long-posited to influence molar onset time is the jaw space available for each molar organ to form within. Here, we tested whether each successive molar initiates only after a minimum threshold of space is created via jaw growth. We used synchrotron-based micro-CT scanning to assess developing molars in situ within jaws of C57BL/6J mice aged E10 to P32, encompassing molar onset to emergence. We compared total jaw, retromolar and molar lengths, and molar onset times, between upper and lower jaws. Initiation time and developmental duration were comparable between molar upper and lower counterparts despite shorter, slower-growing retromolar space in the upper jaw, and despite size differences between upper and lower molars. Timing of molar formation appears unmoved by jaw length including space. Conditions within the dental lamina likely influence molar onset much more than surrounding jaw tissues. We theorize that molar initiation is contingent on sufficient surface area for the physical reorganization of dental epithelium and its invagination of underlying mesenchyme.