Diana Trojaniello

Dr. Diana Trojaniello


Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2014 in Journal of NeuroEngineering and Rehabilitation
Verified
Journal Article
Open access
PDF file
DTDiana Trojaniello
Diana Trojaniello
ANDREA CereattiANDREA Cereatti
ANDREA Cereatti
EPElisa Pelosin
Elisa Pelosin
LALaura Avanzino
Laura Avanzino
AMAnat Mirelman
Anat Mirelman
UCUgo Della Croce
Ugo Della Croce
The step-by-step determination of the spatio-temporal parameters of gait is clinically relevant since it provides an estimation of the variability of specific gait patterns associated with frequent geriatric syndromes. In recent years, several methods, based on the use of magneto-inertial units (MIMUs), have been developed for the step-by-step estimation of the gait temporal parameters. However, most of them were applied to the gait of healthy subjects and/or of a single pathologic population. Moreover, spatial parameters in pathologic populations have been rarely estimated step-by-step using MIMUs. The validity of clinically suitable MIMU-based methods for the estimation of spatio-temporal parameters is therefore still an open issue. The aim of this study was to propose and validate a method for the determination of both temporal and spatial parameters that could be applied to normal and heavily compromised gait patterns. Methods: Two MIMUs were attached above each subject's ankles. An instrumented gait mat was used as gold standard. Gait data were acquired from ten hemiparetic subjects, ten choreic subjects, ten subjects with Parkinson's disease and ten healthy older adults walking at two different gait speeds. The method detects gait events (GEs) taking advantage of the cyclic nature of gait and exploiting some lower limb invariant kinematic characteristics. A combination of a MIMU axes realignment along the direction of progression and of an optimally filtered direct and reverse integration is used to determine the stride length. Results: Over the 4,514 gait cycles analyzed, neither missed nor extra GEs were generated. The errors in identifying both initial and final contact at comfortable speed ranged between 0 and 11 ms for the different groups analyzed. The stride length was estimated for all subjects with less than 3% error. Conclusions: The proposed method is apparently extremely robust since gait speed did not substantially affect its performance and both missed and extra GEs were avoided. The spatio-temporal parameters estimates showed smaller errors than those reported in previous studies and a similar level of precision and accuracy for both healthy and pathologic gait patterns. The combination of robustness, precision and accuracy suggests that the proposed method is suitable for routine clinical use.

21 January 2016 in Sensors
Verified
Journal Article
Open access
PDF file
Andrea ManniniAndrea Mannini
Andrea Mannini
DTDiana Trojaniello
Diana Trojaniello
ANDREA CereattiANDREA Cereatti
ANDREA Cereatti
Angelo Maria SabatiniAngelo Maria Sabatini
Angelo Maria Sabatini
Machine learning methods have been widely used for gait assessment through the estimation of spatio-temporal parameters. As a further step, the objective of this work is to propose and validate a general probabilistic modeling approach for the classification of different pathological gaits. Specifically, the presented methodology was tested on gait data recorded on two pathological populations (Huntington’s disease and post-stroke subjects) and healthy elderly controls using data from inertial measurement units placed at shank and waist. By extracting features from group-specific Hidden Markov Models (HMMs) and signal information in time and frequency domain, a Support Vector Machines classifier (SVM) was designed and validated. The 90.5% of subjects was assigned to the right group after leave-one-subject–out cross validation and majority voting. The long-term goal we point to is the gait assessment in everyday life to early detect gait alterations.

1 September 2015 in Gait & Posture
Verified
Journal Article
Closed access
DTDiana Trojaniello
Diana Trojaniello
ARAndrea Ravaschio
Andrea Ravaschio
JHJeffrey M. Hausdorff
Jeffrey M. Hausdorff
ACAndrea Cereatti
Andrea Cereatti


9 May 2018 in BioMedical Engineering OnLine
Verified
Journal Article
Open access
PDF file
MBMatilde Bertoli
Matilde Bertoli
ACAndrea Cereatti
Andrea Cereatti
DTDiana Trojaniello
Diana Trojaniello
LALaura Avanzino
Laura Avanzino
EPElisa Pelosin
Elisa Pelosin
UCUgo Della Croce
Ugo Della Croce
The use of miniaturized magneto-inertial measurement units (MIMUs) allows for an objective evaluation of gait and a quantitative assessment of clinical outcomes. Spatial and temporal parameters are generally recognized as key metrics for characterizing gait. Although several methods for their estimate have been proposed, a thorough error analysis across different pathologies, multiple clinical centers and on large sample size is still missing. The aim of this study was to apply a previously presented method for the estimate of spatio-temporal parameters, named Trusted Events and Acceleration Direct and Reverse Integration along the direction of Progression (TEADRIP), on a large cohort (236 patients) including Parkinson, mildly cognitively impaired and healthy older adults collected in four clinical centers. Data were collected during straight-line gait, at normal and fast walking speed, by attaching two MIMUs just above the ankles. The parameters stride, step, stance and swing durations, as well as stride length and gait velocity, were estimated for each gait cycle. The TEADRIP performance was validated against data from an instrumented mat. Limits of agreements computed between the TEADRIP estimates and the reference values from the instrumented mat were − 27 to 27 ms for Stride Time, − 68 to 44 ms for Stance Time, − 31 to 31 ms for Step Time and − 67 to 52 mm for Stride Length. For each clinical center, the mean absolute errors averaged across subjects for the estimation of temporal parameters ranged between 1 and 4%, being on average less than 3% (< 30 ms). Stride length mean absolute errors were on average 2% (≈ 25 mm). Error comparisons across centers did not show any significant difference. Significant error differences were found exclusively for stride and step durations between healthy elderly and Parkinsonian subjects, and for the stride length between walking speeds. The TEADRIP method was effectively validated on a large number of healthy and pathological subjects recorded in four different clinical centers. Results showed that the spatio-temporal parameters estimation errors were consistent with those previously found on smaller population samples in a single center. The combination of robustness and range of applicability suggests the use of the TEADRIP as a suitable MIMU-based method for gait spatio-temporal parameter estimate in the routine clinical use. The present paper was awarded the “SIAMOC Best Methodological Paper 2017”.

1 March 2015
Verified
Conference Paper
Closed access
ACAndrea Cereatti
Andrea Cereatti
DTDiana Trojaniello
Diana Trojaniello
UCUgo Della Croce
Ugo Della Croce
An overview of conceptual, analytical and experimental elements to quantitatively describe human kinematics, with specific focus on gait, using magneto-inertial sensors is presented. It includes a review and a taxonomy scheme of the techniques for the estimation of joint kinematics and spatio-temporal gait parameters.