Sung-Jun Park

Dr. Sung-Jun Park


Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 October 2019 in Applied Sciences
Verified
Journal Article
Open access
PDF file
KLkwun mook lim
kwun mook lim
TPTae-Hyun Park
Tae-Hyun Park
SLSung-Jae Lee
Sung-Jae Lee
SPSung-Jun Park
Sung-Jun Park
Incidents of lumbar degenerative diseases, such as spinal stenosis and degenerative spondylolisthesis, are increasing due to the aging population, and as a result, posterior lumbar interbody fusion (PLIF) is widely used. However, the interbody fusion cage used in the fusion surgery has been reported to cause subsidence in the fusion cage of the titanium material and bone nonunion in the case of the polyetheretherketone (PEEK) material cage. Therefore, we aim to reduce the possibility of subsidence of the spinal fusion cage through its elastic modulus difference with the cortical bone of the vertebral body. For the vertebral end plate, which is related to the fusion rate, we also aim to design a new composite vertebral cage, which integrates a cover of porous structure using the additive manufacturing method of titanium alloy to fabricate a prototype, and to biomechanically verify the prototype. The method was as follows. In order to find a similar pore size of human cancellous bone, the pore size was adjusted and the results were measured with SEM. The pore size of each surface was measured individually and the mean value was calculated. Next, an animal experiment was conducted to confirm the degree of fusion of each structural type, and prototypes of various structures were fabricated. The degree of fusion was confirmed by a push down test. A prototype of the fusion cage composed of titanium and PEEK material was fabricated, and the possibility of subsidence by existence of porous structure was confirmed by using the lumbar spine finite element model. Then, the prototype was compared with the composite fusion cage developed by ASTM F2077 and ASTM F2267 methods, and with the commercial PEEK and titanium cages. As a result, the correlation between bone fusion and the porous structure, as well as size of the spine fusion cage composing the composite for porous structure and elasticity, was confirmed. Type 3 structures showed the best performance in bone fusion and the pore size of 1.2 mm was most suitable. In addition, the likelihood of subsidence of a cage with a porous structure was considered to be lower than that of a cage with a solid structure. When the new composite cage combined with two composites was compared with commercial products to verify, the performance was better than that of the existing PEEK material. The subsidence result was superior to the titanium product and showed similar results to PEEK products. In conclusion, the performance value was superior to the existing PEEK material, and the subsidence result was superior to the titanium product and was similar to the PEEK product, and thus, performance-wise, it is concluded that the PEEK product can be completely replaced with the new product.

Verified
Journal Article
Open access
PDF file
SLSoo-Bin Lee
Soo-Bin Lee
JYJonghun Yoon
Jonghun Yoon
SPSung-Jun Park
Sung-Jun Park
DCDong Sik Chae
Dong Sik Chae
Lumbar fusion surgery for treating degenerative spinal diseases has undergone significant advancements in recent years. In addition to posterior instrumentation, anterior interbody fusion techniques have been developed along with various cages for interbody fusion. Recently, expandable cages capable of altering height, lordotic angle, and footprint within the disc space have garnered significant attention. In this manuscript, we review the current status, clinical outcomes, and future prospects of expandable cages for lumbar interbody fusion based on the existing literature. Expandable cages are suitable for minimally invasive spinal surgeries. Small-sized cages can be inserted and subsequently expanded to a larger size within the disc space. While expandable cages generally demonstrate superior clinical outcomes compared to static cages, some studies have suggested comparable or even poorer outcomes with expandable cages than static cages. Careful interpretation through additional long-term follow-ups is required to assess the utility of expandable cages. If these shortcomings are addressed and the advantages are further developed, expandable cages could become suitable surgical instruments for minimally invasive spinal surgeries.

1 May 2020 in International Journal of Pharmaceutics
Verified
Journal Article
Closed access
MQMuhammad Qasim
Muhammad Qasim
NLNguyen Xuan Thanh Le
Nguyen Xuan Thanh Le
TNThi Phuong Thuy Nguyen
Thi Phuong Thuy Nguyen
DCDong Sik Chae
Dong Sik Chae
SPSung-Jun Park
Sung-Jun Park
Nae Yoon LeeNae Yoon Lee
Nae Yoon Lee

HSHee Dong Shin
Hee Dong Shin
DADa Hyun Ahn
Da Hyun Ahn
HLHyun Ah Lee
Hyun Ah Lee
YLYun Kyung Lee
Yun Kyung Lee
HYHee Seung Yang
Hee Seung Yang
SPSung-Jun Park
Sung-Jun Park
Background: Power wheelchair joysticks are often available as standardized ready-made products for patients with severe hand dysfunction. However, standardized joysticks have limitations in accommodating the individualized features of hand dysfunctions. Three-dimensional (3D) printing technology has facilitated active research on the development of joysticks that can overcome such limitations. Methods: Four subjects participated in the study to evaluate driving abilities and satisfaction after using the customized joystick for two weeks. Modified power-mobility indoor driving assessment (PIDA), National Aeronautics and Space Administration task load index (NASA-TLX), and psychosocial impact of assistive devices scale (PIADS; Korean version) were employed for evaluation. Results: In patients 1–3, the modified PIDA scores had the highest values in the pre-test and post-test. In patient 4, the modified PIDA score had a higher value in the post-test (mean value = 4) compared to the pre-test (mean value = 3.33). In all patients, the modified PIDA time was lower in the post-test compared to the pre-test. The NASA-TLX and PIADS values indicate that greater satisfaction was achieved through the usage of customized joysticks in the post-test. Conclusions: All patients can improve their power wheelchair driving abilities and achieve greater satisfaction. Clinical Relevance: Three-dimensional printed customized power wheelchair joysticks can offer enhanced driving abilities and satisfaction to patients with limited hand function owing to severe spinal cord injury.

Verified
Journal Article
Open access
PDF file
SLSumin Lim
Sumin Lim
JCJae-Woo Cho
Jae-Woo Cho
BKBeom-Soo Kim
Beom-Soo Kim
SPSung-Jun Park
Sung-Jun Park
ELEic Ju Lim
Eic Ju Lim
JOJK Oh
JK Oh
We report our experience of preoperative plate contouring for periarticular fractures using three-dimensional printing (3DP) technology and describe its benefits. We enrolled 34 patients, including 11 with humerus midshaft fractures, 12 with tibia plateau fractures, 2 with pilon fractures, and 9 with acetabulum fractures. The entire process of plate contouring over the 3DP model was videotaped and retrospectively analyzed. The total time and number of trials for the intraoperative positioning of precontoured plates and any further intraoperative contouring events were prospectively recorded. The mismatch between the planned and postoperative plate positions was evaluated. The average plate contouring time was 9.2 min for humerus shaft, 13.8 min for tibia plateau fractures, 8.8 min for pilon fractures, and 11.6 min for acetabular fractures. Most precontoured plates (88%, 30/34) could sit on the planned position without mismatch. In addition, only one patient with humerus shaft fracture required additional intraoperative contouring. Preoperative patient specific periarticular plate contouring using a 3DP model is a simple and efficient method that may alleviate the surgical challenges involved in plate contouring and positioning.

4 February 2015 in International Journal of Automotive Technology
Verified
Journal Article
Closed access
PDF file
JSJ. H. Song
J. H. Song
GLG. A. Lee
G. A. Lee
KJK. H. Jung
K. H. Jung
SPSung-Jun Park
Sung-Jun Park