Gerhard Kraft

Prof. Dr. Gerhard Kraft

em. Helmholtz Prof, Biophysics Department, GSI Helmholtzzentrum für Schwerionenforschung GmbH, 64291 Darmstadt, Germany

Research Focus & Metrics

Academic Career Length

29Years (1998-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
Verified
Journal Article
Open access
PDF file
AMAndreas Maier
Andreas Maier
JWJulia Wiedemann
Julia Wiedemann
FRFelicitas Rapp
Felicitas Rapp
FPFranziska Papenfuß
Franziska Papenfuß
Franz RödelFranz Rödel
Franz Rödel
Benjamin FreyBenjamin Frey
Benjamin Frey
Largely unnoticed, all life on earth is constantly exposed to low levels of ionizing radiation. Radon, an imperceptible natural occurring radioactive noble gas, contributes as the largest single fraction to radiation exposure from natural sources. For that reason, radon represents a major issue for radiation protection. Nevertheless, radon is also applied for the therapy of inflammatory and degenerative diseases in galleries and spas to many thousand patients a year. In either case, chronic environmental exposure or therapy, the effect of radon on the organism exposed is still under investigation at all levels of interaction. This includes the physical stage of diffusion and energy deposition by radioactive decay of radon and its progeny and the biological stage of initiating and propagating a physiologic response or inducing cancer after chronic exposure. The purpose of this manuscript is to comprehensively review the current knowledge of radon and its progeny on physical background, associated cancer risk and potential therapeutic effects.

17 December 1999 in Radiation and Environmental Biophysics
Verified
Journal Article
Closed access
PDF file
GKGerhard Kraft
Gerhard Kraft
MSMichael Scholz
Michael Scholz
UBU. Bechthold
U. Bechthold

14 October 2008 in Radiation Oncology
Verified
Journal Article
Open access
PDF file
SGSven Oliver Grözinger
Sven Oliver Grözinger
CBChristoph Bert
Christoph Bert
THThomas Haberer
Thomas Haberer
GKGerhard Kraft
Gerhard Kraft
EREike Rietzel
Eike Rietzel
Background: Intrafractional motion results in local over- and under-dosage in particle therapy with a scanned beam. Scanned beam delivery offers the possibility to compensate target motion by tracking with the treatment beam. Methods: Lateral motion components were compensated directly with the beam scanning system by adapting nominal beam positions according to the target motion. Longitudinal motion compensation to mitigate motion induced range changes was performed with a dedicated wedge system that adjusts effective particle energies at isocenter. Results: Lateral compensation performance was better than 1% for a homogeneous dose distribution when comparing irradiations of a stationary radiographic film and a moving film using motion compensation. The accuracy of longitudinal range compensation was well below 1 mm. Conclusion: Motion compensation with scanned particle beams is technically feasible with high precision.

30 June 2010 in Radiation Oncology
Verified
Journal Article
Open access
PDF file
CBChristoph Bert
Christoph Bert
AGAlexander Gemmel
Alexander Gemmel
NSNami Saito
Nami Saito
NCNaved Chaudhri
Naved Chaudhri
DSDieter Schardt
Dieter Schardt
EREike Rietzel
Eike Rietzel
Scanned ion beam therapy of intra-fractionally moving tumors requires motion mitigation. GSI proposed beam tracking and performed several experimental studies to analyse the dosimetric precision of the system for scanned carbon beams.

1 June 1999 in Strahlentherapie und Onkologie
Verified
Journal Article
Closed access
PDF file
GKGerhard Kraft
Gerhard Kraft

1 February 2009 in New Journal of Physics
Verified
Journal Article
Open access
PDF file
GKGerhard Kraft
Gerhard Kraft
SKS D Kraft
S D Kraft