Second harmonic generation (SHG) microscopy is a commonly used technique to study the organization of collagen within tissues. However, individual collagen fibrils, which have diameters much smaller than the resolution of most optical systems, have not been extensively investigated. Here we probe the structure of individual collagen fibrils using polarization‐resolved SHG (PSHG) microscopy and atomic force microscopy. We find that longitudinally polarized light occurring at the edge of a focal volume of a high numerical aperture microscope objective illuminated with linearly polarized light creates a measurable variation in PSHG signal along the axis orthogonal to an individual collagen fibril. By comparing numerical simulations to experimental data, we are able to estimate parameters related to the structure and chirality of the collagen fibril without tilting the sample out of the image plane, or cutting tissue at different angles, enabling chirality measurements on individual nanostructures to be performed in standard PSHG microscopes. The results presented here are expected to lead to a better understanding of PSHG results from both collagen fibrils and collagenous tissues. Further, the technique presented can be applied to other chiral nanoscale structures such as microtubules, nanowires, and nanoribbons.
Polarization sensitive second harmonic generation (pSHG) microscopy is an imaging technique able to provide, in a non-invasive manner, information related to the molecular structure of second harmonic generation (SHG) active structures, many of which are commonly found in biological tissue. The process of acquiring this information by means of pSHG microscopy requires a scan of the sample using different polarizations of the excitation beam. This process can take considerable time in comparison with the dynamics of in vivo processes. Fortunately, single scan polarization sensitive second harmonic generation (SS-pSHG) microscopy has also been reported, and is able to generate the same information at a faster speed compared to pSHG. In this paper, the orientation of second harmonic active supramolecular assemblies in starch granules is obtained on by means of pSHG and SS-pSHG. These results are compared in the forward and backward directions, showing a good agreement in both techniques. This paper shows for the first time, to the best of the authors’ knowledge, data acquired using both techniques over the exact same sample and image plane, so that they can be compared pixel-to-pixel.
Second harmonic generation (SHG) in biological tissue originates predominantly from noncentrosymmetric fibrillar structures partially oriented within the focal volume (voxel) of a multiphoton excitation microscope. The study is aimed to elucidate fibrillar organization factors influencing SHG intensity, as well as achiral, R, and chiral, C, nonlinear susceptibility tensor component ratios. SHG response is calculated for various configurations of fibrils in a voxel using digital nonlinear microscope. The R and C ratios are calculated using linear incident and outgoing polarization states that simulate polarization-in polarization-out (PIPO) polarimetric measurements. The investigation shows strong SHG intensity dependence on parallel/antiparallel fiber organization. The R and C ratio is strongly influenced by the fiber chirality, tilting of the fibers out of image plane and crossing of the fibers. The study facilitates interpretation of polarimetric SHG microscopy images in terms of ultrastructural organization of fibers in the imaged structures. Statement of Significance Second harmonic generation microscopy is widely used for imaging non-centrosymmetric biological structures such as collagen. The ultrastructure of collagen can be determined with polarimetric SHG microscopy. The coherent nonlinear response of biological structures depends on the 3D orientations and positions of the collagen fibers in the focal volume of the microscope. Here, we show how different fiber organizations and 3D orientations in the focal volume can affect the polarimetric SHG responses. The results are important for understanding and interpreting images obtained with polarimetric SHG microscopy.
Polarimetric second harmonic generation (SHG) microscopy is employed to study partially oriented fibrillar structures. The polarimetric SHG parameters are influenced by three-dimensional (3D) configuration of C 6 symmetry fibrilar structures in the focal volume (voxel) of a microscope. The achiral and chiral susceptibility tensor components ratios (R and C, respectively) are extracted from the linear polarization-in polarization-out (PIPO) measurements. The analytical derivations along with the polarimetric SHG microscopy results obtained from rat tail tendon, rabbit cornea, pig cartilage and meso-tetra (4-sulfonatophenyl) porphine (TPPS 4 ) cylindrical aggregates demonstrate that SHG intensity is affected by parallel/antiparallel arrangements of the fibers, and R and C ratio values change by tilting the fibers out of image plane, as well as by crossing the fibers in 2D and 3D. The polarimetric microscopy results are consistent with the digital microscopy modeling of fibrillar structures. These results facilitate the interpretation of polarimetric SHG microscopy images in terms of 3D organization of fibrilar structures in each voxel of the samples. Statement of Significance: Polarimetric second harmonic generation (SHG) microscopy is used to study partially oriented C 6 symmetry chiral fibrillar structures. The linear polarization-in polarization-out (PIPO) SHG imaging is performed on rat tail tendon, rabbit cornea, pig cartilage tissues and meso-tetra (4-sulfonatophenyl) porphine (TPPS 4 ) cylindrical aggregates. The study demonstrates that SHG intensity is affected by parallel/antiparallel arrangements of the fibers, and the achiral and chiral susceptibility component ratio values change by tilting the fibers out of image plane, as well as by crossing the fibers in 2D and 3D. The polarimetric microscopy results are consistent with the digital microscopy modeling of fibrillar structures. These results facilitate the interpretation of polarimetric SHG microscopy images in terms of 3D organization of fibrillar structures in each voxel of the samples.
Collagen forms dense fibre networks in the human body, with the organisation directly influencing tissue mechanics and function in health and disease. A good understanding of this relation requires proper imaging techniques for visualising the dense collagen network. Previously, computational scattered light imaging was employed as a fast and easy-to-implement technique to retrieve the orientation of multi-directional collagen fibres, but results were not yet validated quantitatively. In this study, we validate the in-plane orientations of collagen fibres determined with computational scattered light imaging by performing comparative measurements with polarimetric second harmonic generation microscopy on rat tendon and bone sections. For rat tendon, sections with and without hematoxylin-and-eosin staining, folded tendon layers, and obliquely cut sections were investigated. Similar fibre orientations were obtained with both techniques in both tissues, with the highest degree of similarity found for in-plane, unidirectional fibres in the tendon sections. The techniques were able to retrieve the orientations of multi-directional crossing collagen fibres in folded rat tendon layers, and results were found to be unaffected by staining. While polarimetric second harmonic generation microscopy provides high resolution and ultrastructural information on collagen, computational scattered light imaging provides large field of view measurements with micrometre resolution.
Birefringence of collagen fibers influences second-harmonic generation (SHG) polarimetric measurements by introducing phase retardation for the incident fundamental beam and the SHG signal. The effect of birefringence on double Stokes polarimetry (DSP) parameters is investigated by imaging unstained rat tail tendon sections of varying thicknesses. In thin sections (≈10 μm thick), birefringence effects can be neglected; however, parameters combining linear and circular polarization states are affected, indicating a presence of complex-valued achiral susceptibility ratio due to fiber chirality. In thicker samples (≈80 μm thick), birefringence significantly affects DSP polarimetric and ultrastructural parameters, although approximate in-plane fiber orientation can still be retrieved. DSP polarimetric parameters enable rapid collagen characterization and are suited for large-area whole-slide investigations in histopathology.