Louise Jennings

Dr. Louise Jennings

orcid

Research Focus & Metrics

Academic Career Length

25Years (2002-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 September 2010 in Journal of Biomedical Materials Research Part B: Applied Biomaterials
Verified
Journal Article
Closed access
PDF file
MAMazen Al‐Hajjar
Mazen Al‐Hajjar
ILIan J. Leslie
Ian J. Leslie
Joanne TipperJoanne Tipper
Joanne Tipper
SWSophie Williams
Sophie Williams
JFJohn Fisher
John Fisher
LJLouise Jennings
Louise Jennings

8 February 2013 in Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine
Verified
Journal Article
Open access
MAMazen Al-Hajjar
Mazen Al-Hajjar
JFJohn Fisher
John Fisher
JTJoanne L Tipper
Joanne L Tipper
SWSophie Williams
Sophie Williams
LJLouise Jennings
Louise Jennings
Ceramic-on-ceramic bearings have become of great interest due to the substantial improvements in the manufacturing techniques and material properties and due to polyethylene wear debris–induced osteolysis and the issues with metal wear debris and ion release by metal-on-metal bearings. Edge loading conditions due to translational malpositioning (microseparation conditions) have been shown to replicate clinically relevant wear mechanisms and increase the wear of ceramic-on-ceramic bearings; thus, it was necessary to test new bearing materials and designs under these adverse conditions. The aim of this study was to assess the effect of increasing head size on the wear of BIOLOX® delta ceramic-on-ceramic bearings under edge loading conditions due to rotational (steep cup inclination angle) and translational (microseparation) malpositioning. In this study, six 36-mm ceramic-on-ceramic bearings (BIOLOX delta, CeramTec, Germany) were tested under standard and edge loading conditions using the Leeds II hip simulator and compared to the 28-mm bearings tested and published previously under identical conditions. The mean wear rate under standard gait conditions was below 0.1 mm3/million cycles for both the 28-mm and the 36-mm ceramic-on-ceramic bearings, and increasing the inclination angle did not affect the wear rates. The introduction of microseparation to the gait cycle increased the wear rate of ceramic-on-ceramic bearing and resulted in stripe wear on the femoral heads. Under microseparation conditions, the wear rate of size 36-mm bearings (0.22 mm3/million cycles) was significantly higher ( p = 0.004) than that for size 28-mm bearings (0.13 mm3/million cycles). This was due to the larger contact area for the larger bearings and deprived lubrication under edge loading conditions. The wear rate of BIOLOX delta ceramic-on-ceramic bearings under microseparation conditions was still very low ( <0.25 mm3/million cycles) compared to earlier generation ceramic-on-ceramic bearings (BIOLOX forte, 1.84 mm3/million cycles) and other bearing materials such as metal-on-metal bearings (2–8 mm3/million cycles).

1 April 2022 in Tissue Engineering Part B: Reviews
Verified
Journal Article
Open access
PSPatrick Statham
Patrick Statham
Elena A JonesElena A Jones
Elena A Jones
LJLouise Jennings
Louise Jennings
HFHazel L. Fermor
Hazel L. Fermor
It is well known that the biomechanical and tribological performance of articular cartilage is inextricably linked to its extracellular matrix (ECM) structure and zonal heterogeneity. Furthermore, it is understood that the presence of native ECM components, such as collagen II and aggrecan, promote healthy homeostasis in the resident chondrocytes. What is less frequently discussed is how chondrocyte metabolism is related to the extracellular mechanical environment, at both the macro and microscale. The chondrocyte is in immediate contact with the pericellular matrix of the chondron, which acts as a mechanocoupler, transmitting external applied loads from the ECM to the chondrocyte. Therefore, components of the pericellular matrix also play essential roles in chondrocyte mechanotransduction and metabolism. Recreating the biomechanical environment through tuning material properties of a scaffold and/or the use of external cyclic loading can induce biosynthetic responses in chondrocytes. Decellularized scaffolds, which retain the native tissue macro- and microstructure also represent an effective means of recapitulating such an environment. The use of such techniques in tissue engineering applications can ensure the regeneration of skeletally mature articular cartilage with appropriate biomechanical and tribological properties to restore joint function. Despite the pivotal role in graft maturation and performance, biomechanical and tribological properties of such interventions is often underrepresented. This review outlines the role of biomechanics in relation to native cartilage performance and chondrocyte metabolism, and how application of this theory can enhance the future development and successful translation of biomechanically relevant tissue engineering interventions. Impact statement: Physiological cartilage function is a key criterion in the success of a cartilage tissue engineering solution. The in situ performance is dependent on the initial scaffold design as well as extracellular matrix deposition by endogenous or exogenous cells. Both biological and biomechanical stimuli serve as key regulators of cartilage homeostasis and maturation of the resulting tissue-engineered graft. An improved understanding of the influence of biomechanics on cellular function and consideration of the final biomechanical and tribological performance will help in the successful development and translation of tissue-engineered grafts to restore natural joint function postcartilage trauma or osteoarthritic degeneration, delaying the requirement for prosthetic intervention.

1 March 2007 in Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine
Verified
Journal Article
Closed access
LJLouise Jennings
Louise Jennings
CBC J Bell
C J Bell
EIE Ingham
E Ingham
RKR D Komistek
R D Komistek
MSM H Stone
M H Stone
JFJ Fisher
J Fisher
In vivo fluoroscopic studies of patients with total knee replacements (TKRs) have shown lift-off of the femoral condyles from the tibial insert. This study investigated the influence of femoral condylar lift-off on the ultra-high molecular weight polyethylene (UHMWPE) wear of fixed bearing (FB) and rotating platform mobile bearing (RP MB) total knee replacements, using a physiological knee joint simulator. In the absence of lift-off, the RP MB knees exhibited a lower wear rate of 5.2;;2.2 mm3 per million cycles (mm3/MC) compared with 8.8;;4.8 mm3/MC for the FB knees. The presence of femoral condylar lift-off was found to accelerate the wear of the FB and RP MB knees tested in this study to 16.4;;2.9 and 16.9;;2.9 mm3/MC respectively. For the RP MB knees the increase in wear rate was more marked, resulting in a similar wear rate for both designs of knee under lift-off conditions. In both cases the medial condyle displayed more wear damage. This study has shown that a small amount of abduction/adduction lift-off and medial-lateral shift increases wear and that the increase in wear is design dependent. In this simulator test, lift-off was simulated on every cycle, whereas the amount of wear and effect of lift-off clinically would depend on the frequency of occurrence of lift-off in vivo.

27 September 2016 in Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine
Verified
Journal Article
Open access
RCRaelene Cowie
Raelene Cowie
ABAdam Briscoe
Adam Briscoe
JFJohn Fisher
John Fisher
LJLouise Jennings
Louise Jennings
PEEK-OPTIMA™ (Invibio Ltd, UK) has been considered as an alternative joint arthroplasty bearing material due to its favourable mechanical properties and the biocompatibility of its wear debris. In this study, the potential to use injection moulded PEEK-OPTIMA™ as an alternative to cobalt chrome in the femoral component of a total knee replacement was investigated in terms of its wear performance. Experimental wear simulation of three cobalt chrome and three PEEK-OPTIMA™ femoral components articulating against all-polyethylene tibial components was carried out under two kinematic conditions: 3 million cycles under intermediate kinematics (maximum anterior-posterior displacement of 5 mm) followed by 3 million cycles under high kinematic conditions (anterior-posterior displacement 10 mm). The wear of the GUR1020 ultra-high-molecular-weight polyethylene tibial components was assessed by gravimetric analysis; for both material combinations under each kinematic condition, the mean wear rates were low, that is, below 5 mm3/million cycles. Specifically, under intermediate kinematic conditions, the wear rate of the ultra-high-molecular-weight polyethylene tibial components was 0.96 ± 2.26 mm3/million cycles and 2.44 ± 0.78 mm3/million cycle against cobalt chrome and PEEK-OPTIMA™ implants, respectively (p = 0.06); under high kinematic conditions, the wear rates were 2.23 ± 1.85 mm3/million cycles and 4.44 ± 2.35 mm3/million cycles, respectively (p = 0.03). Following wear simulation, scratches were apparent on the surface of the PEEK-OPTIMA™ femoral components. The surface topography of the femoral components was assessed using contacting profilometry and showed a statistically significant increase in measured surface roughness of the PEEK-OPTIMA™ femoral components compared to the cobalt chrome implants. However, this did not appear to influence the wear rate, which remained linear over the duration of the study. These preliminary findings showed that PEEK-OPTIMA™ gives promise as an alternative bearing material to cobalt chrome alloy in the femoral component of a total knee replacement with respect to wear performance.

7 June 2013 in Journal of Biomedical Materials Research Part B: Applied Biomaterials
Verified
Journal Article
Open access
PDF file
MAMazen Al‐Hajjar
Mazen Al‐Hajjar
LJLouise Jennings
Louise Jennings
SBSabine Begand
Sabine Begand
TOThomas Oberbach
Thomas Oberbach
DDDaniel Delfosse
Daniel Delfosse
JFJohn Fisher
John Fisher
Further development of ceramic materials for total hip replacement aim to increase fracture toughness and further reduce the incidence of bearing fracture. Edge loading due to translational mal positioning (microseparation) has replicated stripe wear, wear rates, and bimodal wear debris observed on retrievals. This method has replicated the fracture of early zirconia ceramic‐on‐ceramic bearings. This has shown the necessity of introducing microseparation conditions to the gait cycle when assessing the tribological performance of new hip replacement bearings. Two novel ceramic matrix composite materials, zirconia‐toughened alumina (ZTA) and alumina‐toughened zirconia (ATZ), were developed by Mathys Orthopädie GmbH. In this study, ATZ‐on‐ATZ and ZTA‐on‐ZTA bearing combinations were tested and compared with alumina‐on‐alumina (Al2O3‐on‐Al2O3) bearings under adverse microseparation and edge loading conditions using the Leeds II physiological anatomical hip joint simulator. The wear rate (±95% confidence limit) of ZTA‐on‐ZTA was 0.14 ± 0.10 mm3/million cycles and that of ATZ‐on‐ATZ was 0.06 ± 0.004 mm3/million cycles compared with a wear rate of 0.74 ± 1.73 mm3/million cycles for Al2O3‐on‐Al2O3 bearings. Stripe wear was evident on all bearing combinations; however, the stripe formed on the ATZ and ZTA femoral heads was thinner and shallower that that formed on the Al2O3 heads. Posttest phase composition measurements for both ATZ and ZTA materials showed no significant change in the monoclinic zirconia content. ATZ‐on‐ATZ and ZTA‐on‐ZTA showed superior wear resistance properties when compared with Al2O3‐on‐Al2O3 under adverse edge loading conditions. © 2013 The Authors Journal of Biomedical Materials Research Part B: Applied Biomaterials Published by Wiley Periodicals, Inc., 101B: 1456–1462, 2013.