SUNG GU LEE

SUNG GU LEE

orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 September 2018 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
Joon Sung ParkJoon Sung Park
Joon Sung Park
KLKi-Doek Lee
Ki-Doek Lee
SLSUNG GU LEE
SUNG GU LEE
WKWon-Ho Kim
Won-Ho Kim
This letter presents a position sensorless control method of brushless DC (BLDC) motors considering unbalanced zero crossing detection of back electromotive force (back EMF). The zero-crossing point (ZCP) of back EMF voltage is detected by comparing the DC-link voltage with the back EMF voltage. The unbalanced ZCP detection is caused by the DC-link voltage drop, DC-link offset voltage, and a motor having asymmetric back EMFs. Because the sensorless BLDC motor control is based on unbalanced ZCP detection, issues with torque ripple and current ripple may be increased. Therefore, sensorless operation with unbalanced ZCP detection may be unstable. In this study, an improved sensorless control method based on a simple compensation algorithm using ZCP signals is proposed. Using the proposed control method, balanced commutation instants can be obtained and the benefits of high-performance operation of BLDC motors can be accomplished. Through application of the proposed method, the effectiveness of the proposed method was experimentally verified.

5 September 2019 in IEEE Transactions on Industry Applications
Verified
Journal Article
Closed access
SLSUNG GU LEE
SUNG GU LEE
JBJaenam Bae
Jaenam Bae
WKWon-Ho Kim
Won-Ho Kim
A spoke type permanent magnet synchronous motor (Spoke PMSM) generates axial leakage magnetic flux due to its flux-concentrating rotor structure, and therefore degrades the motor performance. Although a three-dimensional finite element method (3D-FEM) can be used to estimate the axial leakage magnetic flux, it requires a significant amount of time for analysis. In this study, a calibration coefficient is proposed to estimate the axial leakage magnetic flux using the two-dimensional finite element method (2D-FEM) instead of 3D-FEM. This calibration coefficient is expressed in terms of the major geometric parameters of a motor and can be calculated using the material information of the permanent magnet and the bridge of the rotor core in 2D-FEM. The validity of the proposed equation is verified through 3D-FEM and other tests.

18 January 2017 in IEEE Transactions on Magnetics
Verified
Journal Article
Closed access
SLSUNG GU LEE
SUNG GU LEE
JLJu Lee
Ju Lee
WKWon-Ho Kim
Won-Ho Kim
The accurate estimation of the performance change according to variations in stack length of motors is important in related industries. A permanent magnet (PM) motor usually represents a characteristic in which its back electromotive force (EMF) constant (K e ) is linearly proportional to stack length. It is an enormous advantage in designing and estimating the performance of PM motors. However, the linearity cannot be held in spoke-type ferrite magnet synchronous motors (SFMSM) due to the axial leakage magnetic flux that is irrelevant to the stack length. Thus, it is possible to accurately analyze the performance of SFMSM using a 3-D finite-element analysis (FEA) method but this method is very inefficient. In this paper, a new relationship formula that can consider the nonlinearity between stack length and back EMF constant in SFMSM is proposed. This formula can estimate the back EMF constant in a new stack length based on the results of 2-D-FEA and 3-D-FEA in a specific stack length. Finally, the validity of this formula is verified through analyzing its accuracy and testing it according to changes in motor parameters.

10 September 2018 in Electronics
Verified
Journal Article
Open access
PDF file
MKMyungchin Kim
Myungchin Kim
SLSUNG GU LEE
SUNG GU LEE
SBSungwoo Bae
Sungwoo Bae
In order to implement reliable and flexible power management among energy sources, a decentralized power management approach for electrical power systems (EPSs) in the more electric aircraft (MEA) is studied. Considering the increased use of electrical power for various functions, the performance of MEA would be determined by the design and operation of the EPS. By using a virtual impedance that includes both a resistive term and an inductive term, autonomous power sharing is realized. Because of the frequency dependence in the virtual impedance, different power sharing ratios between steady state and transient state can be considered. Not only the operation of various power sources is coordinated without supervision of a centralized controller, but also the operation profile of each source can be adjusted to meet output characteristics of each source. To demonstrate the effectiveness of the proposed approach, a series of simulations that consider various virtual impedance configurations were conducted. The proposed approach contributes to a higher level of operational flexibility, while enabling reliable and cost-effective management of MEAs.

13 April 2020 in IEEE Transactions on Applied Superconductivity
Verified
Journal Article
Closed access
SLSUNG GU LEE
SUNG GU LEE
JBJaenam Bae
Jaenam Bae
WKWon-Ho Kim
Won-Ho Kim
Demagnetization of permanent magnets (PMs) directly leads to deterioration of the performance characteristics of a permanent magnet synchronous motor (PMSM). Therefore, the design process of a PMSM generally considers the demagnetization of PMs. In this paper, we propose a design process of spoke-type PMSMs considering the demagnetization performance of PMs and magnetization performance directly related to mass production. Unlike other motors, it is difficult to obtain magnetization performance suitable for mass production using spoke-type PMSM unless magnetization performance is considered in the design stage. Therefore, the design process proposed in this paper would be a good guide for engineers designing spoke-type PMSMs in the industry. Finally, to verify the validity of the proposed design process, a real motor was fabricated, and its performance was evaluated experimentally.

19 May 2020 in Energies
Verified
Journal Article
Open access
PDF file
SHShin-Ki Hong
Shin-Ki Hong
SLSUNG GU LEE
SUNG GU LEE
MKMyungchin Kim
Myungchin Kim
Due to the increasing use of Electric Vehicles (EVs), the effect of the EV charging power demand on the reliability of the power system infrastructure needs to be addressed. In apartment complexes, which have emerged as a common residential type in metropolitan areas and highly populated districts, high charging demand could result in substantial stress to distribution networks. In this work, the effect of EV charging power demand in an apartment complex on the aging of the Distribution Transformer (DT) is studied. A methodology based on the stochastic characterization of vehicle usage profiles and user charging patterns is developed to obtain realistic EV charging demand profiles. Based on the modeled EV charging profile and the transformer thermal model, the effect of different EV penetration ratios on DT aging for an apartment complex in the Republic of Korea is studied. Results for an EV penetration ratio of up to 30% indicated that DT aging could be accelerated by up to 40%, compared to the case without EV charging. To mitigate this accelerated DT aging caused by EV charging, the effectiveness of two integration approaches of Photovoltaic (PV) sources was studied. Based on a case study that included a realistic PV generation profile, it was demonstrated that a significant contribution to DT reliability could be achieved via the operation of PV sources. A more apparent contribution of PV integration was observed with an energy storage installation at higher EV penetration ratios. At an EV penetration ratio of 30%, a maximum decrease of 41.8% in the loss-of-life probability of the DT was achieved. The effects of different PV integration approaches and power management details on DT aging were also studied. The results demonstrate that the EV charging demand could introduce a significant level of stress to DTs and that this impact can be effectively mitigated by installing PV sources. These observations are expected to contribute toward the effective planning of power system infrastructures that support the design of sustainable cities with the widespread use of EVs.