Vratislav Fabián

Dr. Vratislav Fabián

orcid

Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 August 2019 in Sensors
Verified
Journal Article
Open access
PDF file
VFVratislav Fabián
Vratislav Fabián
LMLukas Matera
Lukas Matera
KBKristyna Bayerova
Kristyna Bayerova
Jan HavlíkJan Havlík
Jan Havlík
Vaclav KremenVaclav Kremen
Vaclav Kremen
DZDavid Zemanek
David Zemanek
Cardiovascular diseases are one of most frequent cause of morbidity and mortality in the world. There is an emerging need for integrated, non-invasive, and easy-to-use clinical tools to assess accurately cardiovascular system primarily in the preventative medicine. We present a novel design for a non-invasive pulse wave velocity (PWV) assessment method integrated in a single brachial blood pressure monitor allowing for up to 100 times more sensitive recording of the pressure pulsations based on a brachial occlusion-cuff (suprasystolic) principle. The monitor prototype with built-in proprietary method was validated with a gold standard reference technique SphygmoCor VX device. The blood pressure and PWV were assessed on twenty-five healthy individuals (9 women, age (37 ± 13) years) in a supine position at rest by a brachial cuff blood pressure monitor prototype, and immediately re-tested using a gold standard method. PWV using our BP monitor was (6.67 ± 0.96) m/s compared to PWV determined by SphygmoCor VX (6.15 ± 1.01) m/s. The correlation between methods using a Pearson’s correlation coefficient was r = 0.88 (p < 0.001). The study demonstrates the feasibility of using a single brachial cuff build-in technique for the assessment of the arterial stiffness from a single ambulatory blood pressure assessment.

1 January 2016 in Biomedical Engineering / Biomedizinische Technik
Verified
Journal Article
Closed access
VFVratislav Fabián
Vratislav Fabián
Jan HavlíkJan Havlík
Jan Havlík
JDJan Dvorak
Jan Dvorak
Vaclav KremenVaclav Kremen
Vaclav Kremen
PSPavol Sajgalik
Pavol Sajgalik
BJBruce D. Johnson
Bruce D. Johnson
Systemic arterial blood pressure (BP) is one of the most important parameters of the cardiovascular system. An oscillometric NIBP monitor was specifically designed to measure oscillometric pulsations and mean arterial pressure (MAP) during inflation and deflation of the cuff. Nineteen healthy young (age 23.1±1.7 years; mean±SD) and 35 elderly (83.9±7.9 years; mean±SD) subjects were studied. Differential analysis of MAP during inflation and deflation show mean |ΔMAP|=2.9±2.6 mm Hg in the young group (mean±SD) and |ΔMAP|=6.3±5.2 mm Hg for seniors (mean±SD). There was a significant difference (p<0.05) in means of |ΔMAP| measured during cuff inflation and cuff deflation between both groups. In about 50% of elderly subjects |ΔMAP| was higher than 5 mm Hg. Potential clinical relevance of the method needs to be further evaluated.

1 August 2007
Verified
Conference Paper
Closed access
VFVratislav Fabián
Vratislav Fabián
MJMartin Janouch
Martin Janouch
LNLenka Novakova
Lenka Novakova
OSOlga Stepankova
Olga Stepankova
Results obtained by the modern automatic blood pressure (BP) monitors using oscillometric method are highly dependent on conditions of cardiovascular system of the monitored person. Especially, with people who suffer from cardiovascular diseases (e.g. aterosclerosis) the resulting values differ significantly from those measured by the traditional auscultation method. A reasonable solution for improvement of quality of oscillometric method could be a sophisticated intelligent BP measuring system which applies for evaluation of BP more complex approach taking into account the monitored person's condition of patient cardiovascular system (CS) i.e. the hemodynamic parameters of CS (e.g. heart rate, stroke volume, total peripheral resistance, systemic arterial compliance, pulse wave velocity, augmentnation index etc.). Such a system has to be based on appropriate models of the considered diseases which are validated on real life data. For that purpose, we have started to build a database of real-life oscillometric pulsations waveforms (OPW) complemented by the values of ";auscultation"; blood pressure measurements and additional relevant information about the considered patients (age, sex, etc.) as well as their diagnosis. This data collection requires a special HW device for measurement of the OPW - we have developed such a device and it has been validated in Czech Certified Metrological Centre. Our OPW monitor is connected through the T-pieces and tubes to the cuff, mercury sphygmomanometer and automatic ";oscillometric"; blood pressure monitor. This paper reviews our preliminary results based on analysis of the collected data consisting of more than one thousand OPW corresponing mostly to people above 60 years - auscultation values are measured by educated staff (nurses or doctors).

1 January 2012
Verified
Book Chapter
Closed access
PDF file
Jan HavlíkJan Havlík
Jan Havlík
LKLucie Kučerová
Lucie Kučerová
IKImrich Kohút
Imrich Kohút
JDJan Dvořák
Jan Dvořák
VFVratislav Fabián
Vratislav Fabián

3 September 2025 in Pain and Therapy
Verified
Journal Article
Open access
PDF file
IMIgor Martuliak
Igor Martuliak
ĽCĽuboš Chvála
Ľuboš Chvála
MFMiroslav Ferenčík
Miroslav Ferenčík
VFVratislav Fabián
Vratislav Fabián
MSMatěj Slovák
Matěj Slovák
Introduction Rebox therapy is a form of noninvasive transcutaneous electrotherapy, which delivers microcurrent kilohertz-frequency pulses in multiple points over the target area. Despite decades of use in pain management, clinical evidence supporting Rebox remains inconclusive, with a lack of rigorous sham-controlled trials. This study aimed to evaluate its analgesic effect in a single-center, randomized, double-blind, sham-controlled crossover trial. Methods The study included consecutive patients with non-cancer nociceptive pain with average pain intensity ≥ 4 on a numerical rating scale (NRS), and pain duration of 2–12 weeks (de novo or acutely exacerbated chronic pain). Patients were randomized (1:1) into two arms based on the sequence of stimulation periods. Each period consisted of eight sessions of either Rebox or sham treatment, administered every other working day, with a 1-week washout period. The primary outcome was the difference in the reduction of pain intensity (average and worst pain in the last 24 h) following active versus sham stimulation. Results Seventy-one patients completed the study, with musculoskeletal back pain being the most common indication (n = 60). Compared to the sham, Rebox significantly reduced both average pain (NRS difference: 2.2, 95% CI 0.8–3.6, Cohen’s d = 0.75, p = 0.002) and worst pain (NRS difference: 2.3, 95% CI 1.2–3.5, Cohen’s d = 0.91, p < 0.001). A significant placebo analgesic effect was observed only in the sham-first arm. The treatment was well tolerated, with only minor and transient side effects. Conclusion Rebox demonstrated a significant analgesic effect compared to the sham. The treatment was safe and well tolerated. These findings support integrating Rebox into clinical pain management, warranting further investigation in larger trials.

14 August 2019 in The International Journal of Artificial Organs
Verified
Journal Article
Closed access
PDF file
TCTroy J Cross
Troy J Cross
SPSajgalik Pavol
Sajgalik Pavol
VFVratislav Fabián
Vratislav Fabián
LMLukas Matera
Lukas Matera
SKSudhir S Kushwaha
Sudhir S Kushwaha
BJBruce D Johnson
Bruce D Johnson
Introduction: Long-term use of continuous-flow left ventricular assist devices may have negative consequences for autonomic, cardiovascular and gastrointestinal function. It has thus been suggested that non-invasive monitoring of arterial pulsatility in patients with a left ventricular assist device is highly important for ensuring patient safety and longevity. We have developed a novel, semi-automated frequency-domain-based index of arterial pulsatility that is obtained during suprasystolic occlusions of the upper arm: the ‘cuff pulsatility index’. Purpose: The purpose of this study was to evaluate the relationship between the cuff pulsatility index and invasively determined arterial pulsatility in patients with a left ventricular assist device. Methods: Twenty-three patients with a left ventricular assist device with end-stage heart failure (six females: age = 65 ± 9 years; body mass index = 30.5 ± 3.7 kg m−2) were recruited for this study. Suprasystolic occlusions were performed on the upper arm of the patient’s dominant side, from which the cuff pressure waveform was obtained. Arterial blood pressure was obtained from the radial artery on the contralateral arm. Measurements were obtained in triplicate. The relationship between the cuff pressure and arterial blood pressure waveforms was assessed in the frequency-domain using coherence analysis. A mixed-effects approach was used to assess the relationship between cuff pulsatility index and invasively determined arterial pulsatility (i.e. pulse pressure). Results: The cuff pressure and arterial blood pressure waveforms demonstrated a high coherence up to the fifth harmonic of the cardiac frequency (heart rate). The cuff pulsatility index accurately tracked changes in arterial pulse pressure within a given patient across repeated measurements. Conclusions: The cuff pulsatility index shows promise as a non-invasive index for monitoring residual arterial pulsatility in patients with a left ventricular assist device across time.