Nahuel Muller

Mr. Nahuel Muller

orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 September 2024 in Journal of Applied Physics
Verified
Journal Article
Open access
PDF file
MRM. E. García Redondo
M. E. García Redondo
NMNahuel Muller
Nahuel Muller
JSJ. M. Salum
J. M. Salum
LFL. P. Ferreyro
L. P. Ferreyro
JBJ. D. Bonilla-Neira
J. D. Bonilla-Neira
MWM. Weber
M. Weber
The Microwave SQUID Multiplexer (μMUX) is the device of choice for the readout of a large number of low-temperature detectors in a wide variety of experiments within the fields of astronomy and particle physics. While it offers large multiplexing factors, the system noise performance is highly dependent on the cold- and warm-readout electronic systems used to read it out, as well as the demodulation domain and parameters chosen. In order to understand the impact of the readout systems in the overall detection system noise performance, first, we extended the available μMUX simulation frameworks, including additive and multiplicative noise sources in the probing tones (i.e., phase and amplitude noise), along with the capability of demodulating the scientific data, either in the resonator’s phase or the scattering amplitude. Then, considering the additive noise as a dominant noise source, the optimum readout parameters to achieve minimum system noise were found for both open-loop and flux-ramp demodulation schemes in the aforementioned domains. Later, we evaluated the system noise sensitivity to multiplicative noise sources under the optimum readout parameters. Finally, as a case study, we evaluated the optimal demodulation domain and the expected system noise level for a typical software-defined radio readout system. This work leads to an improved system performance prediction and noise engineering based on the available readout electronics and the selected demodulation domain.

1 August 2018
Verified
Conference Paper
Closed access
AFA. Fontana
A. Fontana
SPS. M. Pazos
S. M. Pazos
Fernando Leonel AguirreFernando Leonel Aguirre
Fernando Leonel Aguirre
FPF. Palumbo
F. Palumbo
Nahuel VegaNahuel Vega
Nahuel Vega
MDMario E. Debray
Mario E. Debray
An experimental evaluation of the sensitivity to Analog Single Events of a full-custom CMOS Operational Amplifier is reported. The output voltage waveform due to single ion impacts was studied, by scanning the entire area of the circuit under test, using the heavy ion microbeam facility at TANDAR laboratory. A two-dimensional map of the transients captured in the design was obtained, in which the grouping of events in the most sensitive transistors of the circuit can be seen, showing great agreement with results obtained by means of a SPICE simulation environment. Experimental validation of sensitivity provides a better insight into the true resilience against single events of a 180nm technology custom circuit, and shows that the microbeam facility is fit to perform integrated circuit irradiation to extract information down to the single transistor resolution.

31 December 2025 in IEEE Transactions on Applied Superconductivity
Verified
Journal Article
Closed access
NMNahuel Muller
Nahuel Muller
JBJ. Bonilla-Neira
J. Bonilla-Neira
JGJ. Geria
J. Geria
MRM. García Redondo
M. García Redondo
LFL. Ferreyro
L. Ferreyro
SKS. Kempf
S. Kempf
The search for primordial B-modes in the cosmic microwave background (CMB) requires highly sensitive and scalable detector systems. The magnetic microbolometer (MMB) is an emerging detector concept that exploits the magnetic properties of paramagnetic materials at sub-kelvin temperatures, offering bolometers with a high dynamic range and low intrinsic noise. In recent years, the microwave SQUID multiplexer ($\mu$MUX) has become a key technology to efficiently read large low-temperature detector arrays, enabling the readout of hundreds to thousands of detectors over a single transmission line with low noise and minimal power dissipation while reducing the cryogenic setup complexity. In this work, we report the design, fabrication and characterization of a $\mu$MUX optimized for MMB detectors and share our latest experimental results from a bolometer prototype. These findings provide valuable insight of the $\mu$MUX in advancing next-generation CMB instrumentation and also demonstrate its suitability for novel detector technologies such as the MMB.

3 June 2019 in Quantum Beam Science
Verified
Journal Article
Open access
PDF file
Nahuel VegaNahuel Vega
Nahuel Vega
NMNahuel Muller
Nahuel Muller
EFEmmanuel Marie de la Fournière
Emmanuel Marie de la Fournière
EHEmilia Beatriz Halac
Emilia Beatriz Halac
MDMario E. Debray
Mario E. Debray
Recently we used the heavy ion microprobe of the Buenos Aires TANDAR Laboratory for Single Event Effects (SEE) and Total Dose (TD) experiments in electronics devices and components, requiring very low beam currents. The facility includes a fast beam switch that allows the control of the ion beam current and a mobile Si PIN (p-type, intrinsic, n-type) diode that directly measures the number of ions hitting the device. The fast beam deflector was used to reduce the current by producing a pulsed beam or generating a quasi-continuous (Poisson-like distributed) beam with currents ranging from tens to hundreds of ions/s. As an application for this current control method we present a single event effect (SEE) pulses map generated by a 32S8+ beam at 75 MeV on two 0.5 µm technology CMOS digital output buffers where the device was formed by cascading four CMOS inverters with increasing sizes from input to output to drive large loads. Using the same concept of pulse width modulated deflection, we developed a novel gradient scanning method. This system allows to produce in a single irradiation a distribution with a cumulative damage with a difference of two orders of magnitude at constant gradient. To demonstrate the method, we irradiated a lithium niobate monocrystal with 32S8+ beam at 75 MeV energy and later analyzed the produced damage by the micro-Raman technique and an optical profilometer.

16 February 2023 in arXiv
Verified
Preprint
Open access
PDF file
JGJuan Manuel Geria
Juan Manuel Geria
MHMatias Rolf Hampel
Matias Rolf Hampel
SKSebastian Kempf
Sebastian Kempf
JBJuan Jose Bonaparte
Juan Jose Bonaparte
LFLuciano Pablo Ferreyro
Luciano Pablo Ferreyro
AEAlberto Etchegoyen
Alberto Etchegoyen
High resolution maps of polarization anisotropies of the Cosmic Microwave Background (CMB) are in high demand, since the discovery of primordial B-Modes in the polarization patterns would confirm the inflationary phase of the Universe that would have taken place before the last scattering of the CMB at the recombination epoch. Transition Edge Sensors (TES) and Microwave Kinetic Inductance Detectors (MKID) are the predominant detector technologies of cryogenic detector array based CMB instruments that search for primordial B-Modes. In this paper we propose another type of cryogenic detector to be used for CMB survey: A magnetic microbolometer (MMB) that is based on a paramagnetic temperature sensor. It is an adaption of state-of-the-art metallic magnetic calorimeters (MMCs) that are meanwhile a key technology for high resolution $\alpha$, $\beta$, $\gamma$ and X-ray spectroscopy as well as the study of neutrino mass. The effort to adapt MMCs for CMB surveys is triggered by their lack of Johnson noise associated with the detector readout, the possibility of straightforward calibration and higher dynamic range given it possesses a broad and smooth responsivity dependence with temperature and the absence of Joule dissipation which simplifies the thermal design. A brief proof of concept case study is analyzed, taking into account typical constraints in CMB measurements and reliable microfabrication processes. The results show that MMBs provide a promising technology for CMB polarization survey as their sensitivity can be tuned for background limited detection of the sky while simultaneously maintaining a low time response to avoid distortion of the point-source response of the telescope. As the sensor technology and its fabrication techniques are compatible with TES based bolometric detector arrays, a change of detector technology would even come with very low cost.

31 March 2026 in IEEE Transactions on Applied Superconductivity
Verified
Journal Article
Closed access
MRM. E. García Redondo
M. E. García Redondo
JNJ. D. Bonilla Neira
J. D. Bonilla Neira
NMNahuel Muller
Nahuel Muller
LFL. P. Ferreyro
L. P. Ferreyro
JGJ. M. Geria
J. M. Geria
MWM. Weber
M. Weber
In this work, we report the experimental readout results of a $µ$ MUX device using a Direct-RF Software-Defined Radio (SDR) prototype based on the ZCU216 Radio-Frequency System-on-Chip (RFSoC) evaluation board. First, the Direct-RF SDR architecture is described. Then, the analog performance of the SDR system was characterized both in loopback and when coupled to the cryogenic multiplexing system to evaluate the noise contributions of the SDR readout system. Later, the SDR system performance was optimized for $µ$ MUX readout, focusing on bolometric applications. Finally, the minimum demodulated flux noise was obtained through the optimally conditioned readout of a $µ$ MUX channel. The results obtained showed a minimum demodulated white flux noise of $\approx 4 \mu \Phi _{0}/\sqrt{Hz}$ in both demodulation domains (i.e. amplitude $\gamma$ and resonator phase $\theta$) and dominated by the cryogenic microwave chain noise temperature of $T_{n}^{cryo}=4.6$ K. These results are comparable to those obtained with traditional SDR architectures and demonstrate that the Direct-RF SDR prototype is suitable for the readout of $µ$ MUX devices.