Magnesium alloys have recently been attracting attention as a degradable biomaterial. They have advantages including non-toxicity, biocompatibility, and biodegradability. To develop magnesium alloys into biodegradable medical materials, previous research has quantitatively analyzed magnesium alloy corrosion by focusing on the overall changes in the alloy. Therefore, the objective of this study is to develop a bioactive material by applying a ceramic oxide coating (magnesia) on AZ31 magnesium alloy through micro-arc oxidation (MAO) process. This MAO process is conducted under pulsed bipolar constant current conditions in a Si- and P-containing electrolyte and the optimal processing parameters in corrosion protection are obtained by the Taguchi method to design a coating with good anti-corrosion performance. The negative duty cycle and treatment time are two deciding factors of the coating’s capability in corrosion protection. Microstructure characterizations are investigated by means of SEM and XRD. The simulation body-fluid solution is utilized for testing the corrosion resistance with the potentiodynamic polarization and the electrochemical impedance test data. Finally, an in vivo testing shows that the MAO-coated AZ31 has good cytocompatibility and anticorrosive properties.
This study aimed to establish a surface modification technology for ZK60 magnesium alloy implants that can degrade uniformly over time and promote bone healing. It proposes a special micro-arc oxidation (MAO) treatment on ZK60 alloy that enables the composite electrolytes to create a coating with better corrosion resistance and solve the problems of uneven and excessive degradation. A magnesium alloy bone screw made in this way was able to promote the bone healing reaction after implantation in rabbits. Additionally, it was found that the MAO-treated samples could be sustained in simulated body-fluid solution, exhibiting excellent corrosion resistance and electrochemical stability. The Ca ions deposited in the MAO coating were not cytotoxic and were beneficial in enhancing bone healing after implantation.
10 December 2023 in Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy
Micro arc oxidation (MAO) is a prominent surface treatment to form bioceramic coating layers with beneficial physical, chemical, and biological properties on the metal substrates for biomaterial applications. In this study, MAO treatment has been performed to modify the surface characteristics of AZ31 Mg alloy to enhance the biocompatibility and corrosion resistance for implant applications by using an electrolytic mixture of Ca3(PO4)2 and C10H16N2O8 (EDTA) in the solutions. For this purpose, the calcium phosphate (Ca-P) containing thin film was successfully fabricated on the surface of the implant material. After in-vivo implantation into the rabbit bone for four weeks, the apparent growth of soft tissues and bone healing effects have been documented. The morphology, microstructure, chemical composition, and phase structures of the coating were identified by SEM, XPS, and XRD. The corrosion resistance of the coating was analyzed by polarization and salt spray test. The coatings consist of Ca-P compounds continuously have proliferation activity and show better corrosion resistance and lower roughness in comparison to mere MAO coated AZ31. The corrosion current density decreased to approximately 2.81 × 10−7 A/cm2 and roughness was reduced to 0.622 μm. Thus, based on the results, it was anticipated that the development of degradable materials and implants would be feasible using this method. This study aims to fabricate MAO coatings for orthopedic magnesium implants that can enhance bioactivity, biocompatibility, and prevent additional surgery and implant-related infections to be used in clinical applications.
Aluminum (Al) alloys are lightweight and machinable and have been widely used in industrial applications, particularly the formation of complex mechanical parts. However, the 5052 Al alloy frequently encounters problems like corrosion and wear during its service life, significantly impacting the equipment’s longevity. This study investigated the effects of pulse voltage (320 to 400 V) and frequency (50 to 200 Hz) on the growth and surface morphology of 5052 Al alloy films formed through micro-arc oxidation (MAO) to improve their corrosion and wear resistance while maintaining a surface roughness of less than 1 μm. The results indicate that higher operating voltages and frequencies correlated with increased thickness in the resulting ceramic oxide films formed using MAO. In addition, as the pulse frequency increased, the distribution of the holes became more uniform across the surface. We examined the surface and cross-sectional morphology, as well as the thickness of the MAO coatings, through scanning electron microscopy (SEM). The corrosion and wear resistance of the MAO coatings formed under different electrical parameters were analyzed using electrochemical corrosion tests and scratch tests. The MAO coatings produced at 400 V and 200 Hz were the thickest, at approximately 4.8 μm, and demonstrated superior corrosion and wear resistance. These coatings demonstrate significantly reduced wear width, highlighting their exceptional resistance to corrosion and wear. Hole cracking occurred only above the top layer of the coating and not beneath the mid-layer, which protected the substrate from damage due to the direct passage of Cl ions through the holes.
10 September 2024 in The International Journal of Advanced Manufacturing Technology