An open type of microchannel with diamond pin fins (OM-DPFs) is introduced for the cooling of high-performance electronic chips. For a Reynolds number (Re) of 247~1173, a three-dimensional model is established to explore the hydrothermal properties of the OM-DPF and compare it to traditional heat sinks with closed rectangular microchannels (RMs), heat sinks with open microchannels (OMs), and the results in the existing research. Firstly, the synergy between tip clearance and pin fins on the hydrothermal properties is discussed. Secondly, the entropy production principle is adopted to analyze the irreversible losses for different heat sinks. Lastly, the total efficiencies of different heat sinks are assessed. The RMs present the worst heat transfer with the lowest friction loss. For the OMs, the temperature and pressure drop are decreased slightly compared to those of the RMs, and the irreversible loss is reduced by 4% at Re = 1173 because of the small tip clearance. But the total efficiency is lower than that of the RMs because the pressure drop advantage is offset by the weak heat transfer. For the OM-DPF, the combined structure has a noticeable impact on the multiple physical fields and hydrothermal characteristics, which present the best thermal performance at the cost of the highest friction loss. The irreversible loss of heat transfer in the OM-DPF is reduced obviously, but the friction irreversible loss significantly increases at high Re values. At Re = 429, the total entropy production of the OM-DPF is reduced by 47.57% compared with the RM. Compared to the OM and the single-pin fin structure in the literature, the total efficiency of the OM-DPF is increased by 14.56% and 40.32% at Re = 614. For a pump power of 0.1 W, the total thermal resistance (Rth) of the OM-DPF is dropped by 23.77% and 21.19% compared to the RM and OM. For a similar Rth, the pump power of the combined structure is 63.64% and 42.86% lower than that of the RM and OM. Thus, the novel combined heat sink can achieve efficient heat removal while controlling the energy consumption of liquid cooling systems, which has bright application prospects.
In order to improve the efficiency of the system and promote its application in other industries, the performance of a thermoelectric subcooled CO2 transcritical heat pump system was studied. A simulation model of the system was established using steady-state lumped parameter technology, and the experimental data were compared with the simulation results. The effects of cooling and chilled water flow rate and temperature, subcooling degree, compressor discharge pressure on the coefficient of performance (COP), and heating coefficient of performance (COPh) were analyzed. The results showed that COP/COPh increased with the increase in cooling and chilled water flow rate and chilled water temperature and decreased with the increase in cooling water temperature. The experimental COPh and COP of the system with a thermoelectric subcooler increased by 4.19% and 4.62%, respectively, compared to the system without it. The simulated data was in good agreement with the experimental data, and the error was within 10%, thus verifying the correctness of the model. When the subcooling degree increased to 11 °C, the system simulation results showed that COP/COPh increased by about 40% and 13.3%, respectively. The optimal high pressure was about 8.0 MPa, which corresponded to the maximum COP and COPh of the system of 3.25 and 4.25, respectively. The research results can provide a theoretical basis for future system optimization.
27 October 2014 in International Journal of Green Energy
Heat rejection pressure plays an important role in designing a transcritical CO2 refrigeration system, and it has an optimal value to maximize the system’s coefficient of performance (COP). With a thermodynamic simulation model, the optimal heat rejection pressure is studied in the paper for an expander cycle, as well as conventional throttle valve cycle. The effects of compressor efficiency, expander efficiency, gas cooler outlet temperature, and evaporation temperature on the optimal heat rejection pressure are analyzed. It is the first time for a transcritical CO2 expander cycle that the optimal heat rejection pressure is correlated with the gas cooler outlet temperature and the evaporation temperature at given compressor efficiency and expander efficiency. The average deviation from the correlation to simulation results is less than 1.0%. The correlation provides a guideline to system development and performance optimization of a transcritical CO2 expander cycle.
To investigate the performance of transcritical CO2 quasi-secondary compression cycle with ejector (TCIEJ) for heat pump water heaters, the thermodynamic model of TCIEJ is established based on the pinch point, and TCEX, TCEJ, and TCI are selected as comparisons. The effects of changing high pressure and ambient temperature on the heating COP and compressor exhaust temperature are analyzed, and the influence of cooling water inlet and outlet temperature and vapor injection pressure on TCIEJ is further analyzed. The results show that there are optimal high pressures that make the heating COP of the four heat pump cycles reach the maximum value, of which TCIEJ has the best performance. At an ambient temperature of −15 °C, the maximum heating COP of TCIEJ increased by about 20.5%, 14.9%, and 7.9% compared with TCEX, TCEJ, and TCI. With the increase in ambient temperature, the optimal high pressure continues to increase, and the corresponding maximum heating COP gradually increases. Selecting the geometric mean of high pressure and evaporation pressure as the optimal vapor injection pressure for TCIEJ, the error is small compared to the actual optimal vapor injection pressure. With the increase in ambient temperature and cooling water outlet temperature, the optimal high pressure of TCIEJ continues to increase, and the correlation formula of optimal high pressure is fitted according to the simulation results.
19 April 2010 in Frontiers of Energy and Power Engineering in China