Bernardo Patella

Dr. Bernardo Patella

Applied Physical Chemistry Lab, Department of Engineering, University of Palermo, 90128 Palermo, Italy

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 August 2021 in Electrochimica Acta
Verified
Journal Article
Closed access
FMFrancesca Mazzara
Francesca Mazzara
BPBernardo Patella
Bernardo Patella
Giuseppe AielloGiuseppe Aiello
Giuseppe Aiello
AOAlan O'Riordan
Alan O'Riordan
CTClaudia Torino
Claudia Torino
Rosalinda InguantaRosalinda Inguanta
Rosalinda Inguanta

1 January 2021 in Sensors and Actuators B: Chemical
Verified
Journal Article
Closed access
BPBernardo Patella
Bernardo Patella
MBM. Buscetta
M. Buscetta
SVS. Di Vincenzo
S. Di Vincenzo
MFM. Ferraro
M. Ferraro
GAG. Aiello
G. Aiello
CCC. Cipollina
C. Cipollina

5 July 2021 in Chemosensors
Verified
Journal Article
Open access
PDF file
FMFrancesca Mazzara
Francesca Mazzara
BPBernardo Patella
Bernardo Patella
CDChiara D’agostino
Chiara D’agostino
Maria Giuseppina BrunoMaria Giuseppina Bruno
Maria Giuseppina Bruno
Sonia CarboneSonia Carbone
Sonia Carbone
Rosalinda InguantaRosalinda Inguanta
Rosalinda Inguanta
Nowadays, we are assisting in the exceptional growth in research relating to the development of wearable devices for sweat analysis. Sweat is a biofluid that contains useful health information and allows a non-invasive, continuous and comfortable collection. For this reason, it is an excellent biofluid for the detection of different analytes. In this work, electrochemical sensors based on polyaniline thin films deposited on the flexible substrate polyethylene terephthalate coated with indium tin oxide were studied. Polyaniline thin films were abstained by the potentiostatic deposition technique, applying a potential of +2 V vs. SCE for 90 s. To improve the sensor performance, the electronic substrate was modified with reduced graphene oxide, obtained at a constant potential of −0.8 V vs. SCE for 200 s, and then polyaniline thin films were electrodeposited on top of the as-deposited substrate. All samples were characterized by XRD, SEM, EDS, static contact angle and FT-IR/ATR analysis to correlate the physical-chemical features with the performance of the sensors. The obtained electrodes were tested as pH sensors in the range from 2 to 8, showing good behavior, with a sensitivity of 62.3 mV/pH, very close to a Nernstian response, and a reproducibility of 3.8%. Interference tests, in the presence of competing ions, aimed to verify the selectivity, were also performed. Finally, a real sweat sample was collected, and the sweat pH was quantified with both the proposed sensor and a commercial pH meter, showing an excellent concordance.

Verified
Journal Article
Open access
PDF file
CCChiara Cipollina
Chiara Cipollina
ABAndreina Bruno
Andreina Bruno
SFSalvatore Fasola
Salvatore Fasola
MCMarta Cristaldi
Marta Cristaldi
BPBernardo Patella
Bernardo Patella
EPElisabetta Pace
Elisabetta Pace
Exposure of the airways epithelium to environmental insults, including cigarette smoke, results in increased oxidative stress due to unbalance between oxidants and antioxidants in favor of oxidants. Oxidative stress is a feature of inflammation and promotes the progression of chronic lung diseases, including Chronic Obstructive Pulmonary Disease (COPD). Increased oxidative stress leads to exhaustion of antioxidant defenses, alterations in autophagy/mitophagy and cell survival regulatory mechanisms, thus promoting cell senescence. All these events are amplified by the increase of inflammation driven by oxidative stress. Several models of bronchial epithelial cells are used to study the molecular mechanisms and the cellular functions altered by cigarette smoke extract (CSE) exposure, and to test the efficacy of molecules with antioxidant properties. This review offers a comprehensive synthesis of human in-vitro and ex-vivo studies published from 2011 to 2021 describing the molecular and cellular mechanisms evoked by CSE exposure in bronchial epithelial cells, the most used experimental models and the mechanisms of action of cellular antioxidants systems as well as natural and synthetic antioxidant compounds.

1 August 2021 in Electrochimica Acta
Verified
Journal Article
Closed access
BBBiagio Buccheri
Biagio Buccheri
FGFabrizio Ganci
Fabrizio Ganci
BPBernardo Patella
Bernardo Patella
GAGiuseppe Aiello
Giuseppe Aiello
PMPhilippe Mandin
Philippe Mandin
Rosalinda InguantaRosalinda Inguanta
Rosalinda Inguanta

18 May 2023 in Electrochimica Acta
Verified
Journal Article
Open access
BPBernardo Patella
Bernardo Patella
APAntonino Parisi
Antonino Parisi
NMNadia Moukri
Nadia Moukri
FGFederico Gitto
Federico Gitto
ABAlessandro Busacca
Alessandro Busacca
Rosalinda InguantaRosalinda Inguanta
Rosalinda Inguanta