Ruiming Luo

Dr. Ruiming Luo


Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 October 2019 in IEEE Transactions on Neural Systems and Rehabilitation Engineering
Verified
Journal Article
Closed access
RLRuiming Luo
Ruiming Luo
SSShouqian Sun
Shouqian Sun
XZXianfu Zhang
Xianfu Zhang
TZTang Zhichuan
Tang Zhichuan
WWWeide Wang
Weide Wang
As surface electromyogram (sEMG) signals have the ability to detect human movement intention, they are commonly used to be control inputs. However, gait sub-phase classification typically requires monotonous manual labeling process, and commercial sEMG acquisition devices are quite bulky and expensive, thus current sEMG-based gait sub-phase recognition systems are complex and have poor portability. This study presents a low-cost but effective end-to-end sEMG-based gait sub-phase recognition system, which contains a wireless multi-channel signal acquisition device simultaneously collecting sEMG of thigh muscles and plantar pressure signals, and a novel neural network-based sEMG signal classifier combining long-short term memory (LSTM) with multilayer perceptron (MLP). We evaluated the system with subjects walking under five conditions: flat terrain at 5 km/h, flat terrain at 3 km/h, 20 kg backpack at 5 km/h, 20 kg shoulder bag at 5 km/h and 15∘ slope at 5 km/h. Experimental results show that the proposed method achieved average classification accuracies of 94.10%, 87.25%, 90.71%, 94.02%, and 87.87%, respectively, which were significantly higher than existing recognition methods. Additionally, the proposed system had a good real-time performance with low average inference time in the range of 3.25 3.31 ms.

17 March 2022 in SN Applied Sciences
Verified
Journal Article
Open access
PDF file
NZNing Zhang
Ning Zhang
WWWang weixing
Wang weixing
SHSi-Yuan Huang
Si-Yuan Huang
RLRuiming Luo
Ruiming Luo
There was a problem of great distraction in traditional touch interactive operation of in-vehicle information interface, but the application of gesture recognition technology on in-vehicle system improved this problem. However, users had less experience in this new interactive mode, and the cognitive deviation of the agreement between gestures and commands could directly affect the safety of drivers. The main purpose of this paper was to obtain the user's preference mid-air gestures for the in-vehicle information interface by using the user-elicitation method. In addition, the optimized gesture recognition network structure was applied to the prototype system of in-vehicle information interaction with user-defined mid-air gestures developed by us, and the effectiveness of the system was evaluated by collecting eye movement indicators of users through the simulation of driving eye movement experiments. In the process of user elicitation, the principle of command prompt and agreement rate was introduced. According to the agreement rate elicited by users (AR = .397), we got the gesture consensus set design direction of in-vehicle information control. The experimental results of the eye movement index showed that the method of user-defined mid-air gestures can effectively improve driving safety on in-vehicle media control, and reduced the distraction of users when driving compared with the traditional touch-based method. Article highlights: The user's preferred in-vehicle media control task gestures were obtained through the user elicitation method. Constructed an in-vehicle secondary task control prototype system based on gesture recognition. The eye movement experiment proved that the prototype system can reduce the user's distraction when operating the in-vehicle's secondary tasks.

15 December 2021 in Sensors
Verified
Journal Article
Open access
PDF file
XZXianfu Zhang
Xianfu Zhang
YHYuping Hu
Yuping Hu
RLRuiming Luo
Ruiming Luo
CLChao Li
Chao Li
TZTang Zhichuan
Tang Zhichuan
Surface electromyogram (sEMG) signals are widely employed as a neural control source for lower-limb exoskeletons, in which gait recognition based on sEMG is particularly important. Many scholars have taken measures to improve the accuracy of gait recognition, but several real-time limitations affect its applicability, of which variation in the load styles is obvious. The purposes of this study are to (1) investigate the impact of different load styles on gait recognition; (2) study whether good gait recognition performance can be obtained when a convolutional neural network (CNN) is used to deal with the sEMG image from sparse multichannel sEMG (SMC-sEMG); and (3) explore whether the control system of the lower-limb exoskeleton trained by sEMG from part of the load styles still works efficiently in a real-time environment where multiload styles are required. In addition, we discuss an effective method to improve gait recognition at the levels of the load styles. In our experiment, fifteen able-bodied male graduate students with load (20% of body weight) and using three load styles (SBP = backpack, SCS = cross shoulder, SSS = straight shoulder) were asked to walk uniformly on a treadmill. Each subject performed 50 continuous gait cycles under three speeds (V3 = 3 km/h, V5 = 5 km/h, and V7 = 7 km/h). A CNN was employed to deal with sEMG images from sEMG signals for gait recognition, and back propagation neural networks (BPNNs) and support vector machines (SVMs) were used for comparison by dealing with the same sEMG signal. The results indicated that (1) different load styles had remarkable impact on the gait recognition at three speeds under three load styles (p < 0.001); (2) the performance of gait recognition from the CNN was better than that from the SVM and BPNN at each speed (84.83%, 81.63%, and 83.76% at V3; 93.40%, 88.48%, and 92.36% at V5; and 90.1%, 86.32%, and 85.42% at V7, respectively); and (3) when all the data from three load styles were pooled as testing sets at each speed, more load styles were included in the training set, better performance was obtained, and the statistical analysis suggested that the kinds of load styles included in training set had a significant effect on gait recognition (p = 0.002), from which it can be concluded that the control system of a lower-limb exoskeleton trained by sEMG using only some load styles is not sufficient in a real-time environment.