Jesús Mateo

Dr. Jesús Mateo

orcid

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 March 2015 in Maturitas
Verified
Journal Article
Closed access
AHAntonio Herrera
Antonio Herrera
JMJesús Mateo
Jesús Mateo
JGJorge Gil-Albarova
Jorge Gil-Albarova
ALAntonio Lobo-Escolar
Antonio Lobo-Escolar
JAJosé M. Artigas
José M. Artigas
LGLuis Gracia
Luis Gracia

8 July 2016 in PLOS ONE
Verified
Journal Article
Open access
PDF file
SGSergio Gabarre
Sergio Gabarre
AHAntonio Herrera
Antonio Herrera
EIElena Ibarz
Elena Ibarz
JMJesús Mateo
Jesús Mateo
JGJorge Gil-Albarova
Jorge Gil-Albarova
LGLuis Gracia
Luis Gracia
A comparative study between two stems (Linea Anatomic and Minihip) has been performed in order to analyse the differences in their biomechanical behaviour, concerning stem micromotions and load transmission between stem and bone. From the corresponding finite element models, a parametric study was carried out to quantify ranges of micromotions taking into account: friction coefficient in the stem-bone interface, press-fit and two types of gait cycle. Micromotions were evaluated for each stem at six different levels along repeated gait cycles. An initial and marked stem subsidence at the beginning of the simulation was observed, followed by an asymptotic decrease due to friction forces. Once migration occurs, a repeated reversible cyclic micromotion is developed and stabilized as gait cycle times are simulated. The general motion pattern exhibited higher amplitude of micromotion for Minihip compared to Linea stem. The load transmission mechanism was analyzed, identifying the main internal forces. The results show higher local forces for Minihip stem up to 80% greater than for Linea stem. The differences of design between Minihip and Linea conditioned different distributions of load, influencing the posterior stress-shielding. Consequently, short stems require high bone stock and quality should, being indicated for young patients with high bone quality.

27 August 2014 in BioMed Research International
Verified
Journal Article
Open access
PDF file
SGSergio Gabarre
Sergio Gabarre
AHAntonio Herrera
Antonio Herrera
JMJesús Mateo
Jesús Mateo
EIElena Ibarz
Elena Ibarz
ALAntonio Lobo-Escolar
Antonio Lobo-Escolar
LGLuis Gracia
Luis Gracia
Nowadays, a growing number of young and more active patients receive hip replacement. More strenuous activities in such patients involve higher friction and wear rates, with friction on the bearing surface being crucial to ensure arthroplasty survival in the long term. Over the last years, the polycarbonate-urethane has offered a feasible alternative to conventional bearings. A finite element model of a healthy hip joint was developed and adjusted to three gait phases (heel strike, mid-stance, and toe-off), serving as a benchmark for the assessment of the results of joint replacement model. Three equivalent models were made with the polycarbonate-urethane Tribofit system implanted, one for each of the three gait phases, after reproducing a virtual surgery over the respective healthy models. Standard body-weight loads were considered: 230% body-weight toe-off, 275% body-weight mid-stance, and 350% body-weight heel strike. Contact pressures were obtained for the different models. When comparing the results corresponding to the healthy model to polycarbonate-urethane joint, contact areas are similar and so contact pressures are within a narrower value range. In conclusion, polycarbonate-urethane characteristics are similar to those of the joint cartilage. So, it is a favorable alternative to traditional bearing surfaces in total hip arthroplasty, especially in young patients.

21 January 2023 in Polymers
Verified
Journal Article
Open access
PDF file
Miroslav SloufMiroslav Slouf
Miroslav Slouf
VGVeronika Gajdosova
Veronika Gajdosova
JDJiri Dybal
Jiri Dybal
RSRoman Sticha
Roman Sticha
PFPetr Fulín
Petr Fulín
PBPierangiola Bracco
Pierangiola Bracco
This contribution lays the foundation for the European database of explanted UHMWPE liners from total joint replacements. Three EU countries (Czech Republic, Italy and Spain) have joined their datasets containing anonymized patient data (such as age and BMI), manufacturer data (such as information on UHMWPE crosslinking, thermal treatment and sterilization), orthopedic evaluation (such as total duration of the implant in vivo and reasons for its revision) and material characterization (such as oxidative degradation and micromechanical properties). The joined database contains more than 500 entries, exhibiting gradual growth, and it is beginning to show interesting trends, which are discussed in our contribution, including (i) strong correlations between UHMWPE oxidative degradation, degree of crystallinity and microhardness; (ii) statistically significant differences between UHMWPE liners with different types of sterilization; (iii) realistic correlations between the extent of oxidative degradation and the observed reasons for total joint replacement failures. Our final objective and task for the future is to continuously expand the database, involving researchers from other European countries, in order to create a robust tool that will contribute to the better understanding of structure–properties–performance relationships in the field of arthroplasty implants.

14 November 2012 in BioMedical Engineering OnLine
Verified
Journal Article
Open access
PDF file
ELEnrique López
Enrique López
EIElena Ibarz
Elena Ibarz
AHAntonio Herrera
Antonio Herrera
JMJesús Mateo
Jesús Mateo
ALAntonio Lobo-Escolar
Antonio Lobo-Escolar
LGLuis Gracia
Luis Gracia
Background: Osteoporotic hip fractures represent major cause of disability, loss of quality of life and even mortality among the elderly population. Decisions on drug therapy are based on the assessment of risk factors for fracture, from BMD measurements. The combination of biomechanical models with clinical studies could better estimate bone strength and supporting the specialists in their decision. Methods: A model to assess the probability of fracture, based on the Damage and Fracture Mechanics has been developed, evaluating the mechanical magnitudes involved in the fracture process from clinical BMD measurements. The model is intended for simulating the degenerative process in the skeleton, with the consequent lost of bone mass and hence the decrease of its mechanical resistance which enables the fracture due to different traumatisms. Clinical studies were chosen, both in non-treatment conditions and receiving drug therapy, and fitted to specific patients according their actual BMD measures. The predictive model is applied in a FE simulation of the proximal femur. The fracture zone would be determined according loading scenario (sideway fall, impact, accidental loads, etc.), using the mechanical properties of bone obtained from the evolutionary model corresponding to the considered time. Results: BMD evolution in untreated patients and in those under different treatments was analyzed. Evolutionary curves of fracture probability were obtained from the evolution of mechanical damage. The evolutionary curve of the untreated group of patients presented a marked increase of the fracture probability, while the curves of patients under drug treatment showed variable decreased risks, depending on the therapy type. Conclusion: The FE model allowed to obtain detailed maps of damage and fracture probability, identifying high-risk local zones at femoral neck and intertrochanteric and subtrochanteric areas, which are the typical locations of osteoporotic hip fractures. The developed model is suitable for being used in individualized cases. The model might better identify at-risk individuals in early stages of osteoporosis and might be helpful for treatment decisions.

10 February 2020 in Injury
Verified
Journal Article
Closed access
PDF file
AHA. Herrera
A. Herrera
JAJ. Albareda
J. Albareda
SGS. Gabarre
S. Gabarre
EIE. Ibarz
E. Ibarz
SPSergio Puértolas
Sergio Puértolas
LGLuis Gracia
Luis Gracia