Elena Ibarz

Dr. Elena Ibarz


Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 2020 in Journal of the Mechanical Behavior of Biomedical Materials
Verified
Journal Article
Closed access
SPSergio Puértolas
Sergio Puértolas
EPEstefanía Peña
Estefanía Peña
AHAntonio Herrera
Antonio Herrera
EIElena Ibarz
Elena Ibarz
LGLuis Gracia
Luis Gracia

1 March 2015 in Maturitas
Verified
Journal Article
Closed access
AHAntonio Herrera
Antonio Herrera
JMJesús Mateo
Jesús Mateo
JGJorge Gil-Albarova
Jorge Gil-Albarova
ALAntonio Lobo-Escolar
Antonio Lobo-Escolar
JAJosé M. Artigas
José M. Artigas
LGLuis Gracia
Luis Gracia

30 June 2010 in BMC Musculoskeletal Disorders
Verified
Journal Article
Open access
PDF file
AHAntonio Herrera
Antonio Herrera
FMFernando Martínez
Fernando Martínez
DIDaniel Iglesias
Daniel Iglesias
JCJosé Cegoñino
José Cegoñino
EIElena Ibarz
Elena Ibarz
LGLuis Gracia
Luis Gracia
Primary stability of the graft is essential in anterior cruciate ligament surgery. An optimal method of fixation should be easy to insert and provide great resistance against pull-out forces.

28 May 2010 in BioMedical Engineering OnLine
Verified
Journal Article
Open access
PDF file
LGLuis Gracia
Luis Gracia
EIElena Ibarz
Elena Ibarz
SPSergio Puértolas
Sergio Puértolas
JCJosé Cegoñino
José Cegoñino
FLFernando López-Prats
Fernando López-Prats
AHAntonio Herrera
Antonio Herrera
A hip replacement with a cemented or cementless femoral stem produces an effect on the bone called adaptive remodelling, attributable to mechanical and biological factors. All of the cementless prostheses designs try to achieve an optimal load transfer in order to avoid stress-shielding, which produces an osteopenia. Long-term densitometric studies taken after implanting ABG-I and ABG-II stems confirm that the changes made to the design and alloy of the ABG-II stem help produce less proximal atrophy of the femur. The simulation with FE allowed us to study the biomechanical behaviour of two stems. The aim of this study was, if possible, to correlate the biological and mechanical findings. Both models with prostheses ABG-I and II have been simulated in five different moments of time which coincide with the DEXA measurements: postoperative, 6 months, 1, 3 and 5 years, in addition to the healthy femur as the initial reference. For the complete comparative analysis of both stems, all of the possible combinations of bone mass (group I and group II of pacients in two controlled studies for ABG-I and II stems, respectively), prosthetic geometry (ABG-I and ABG-II) and stem material (Wrought Titanium or TMZF) were simulated. In both groups of bone mass an increase of stress in the area of the cancellous bone is produced, which coincides with the end of the HA coating, as a consequence of the bottleneck effect which is produced in the transmission of loads, and corresponds to Gruen zones 2 and 6, where no osteopenia can be seen in contrast to zones 1 and 7. In this study it is shown that the ABG-II stem is more effective than the ABG-I given that it generates higher tensional values on the bone, due to which proximal bone atrophy diminishes. This biomechanical behaviour with an improved transmission of loads confirmed by means of FE simulation corresponds to the biological findings obtained with Dual-Energy X-Ray Absorptiometry (DEXA).

23 May 2020 in Polymers
Verified
Journal Article
Open access
PDF file
RARafael Tobajas Alonso
Rafael Tobajas Alonso
DEDaniel Elduque
Daniel Elduque
EIElena Ibarz
Elena Ibarz
CJCarlos Javierre
Carlos Javierre
LGLuis Gracia
Luis Gracia
Most of the mechanical components manufactured in rubber materials experience fluctuating loads, which cause material fatigue, significantly reducing their life. Different models have been used to approach this problem. However, most of them just provide life prediction only valid for each of the specific studied material and type of specimen used for the experimental testing. This work focuses on the development of a new generalized model of multiaxial fatigue for rubber materials, introducing a multiparameter variable to improve fatigue life prediction by considering simultaneously relevant information concerning stresses, strains, and strain energies. The model is verified through its correlation with several published fatigue tests for different rubber materials. The proposed model has been compared with more than 20 different parameters used in the specialized literature, calculating the value of the R2 coefficient by comparing the predicted values of every model, with the experimental ones. The obtained results show a significant improvement in the fatigue life prediction. The proposed model does not aim to be a universal and definitive approach for elastomer fatigue, but it provides a reliable general tool that can be used for processing data obtained from experimental tests carried out under different conditions.

15 June 2018 in Polymers
Verified
Journal Article
Open access
PDF file
RARafael Tobajas Alonso
Rafael Tobajas Alonso
DEDaniel Elduque
Daniel Elduque
EIElena Ibarz
Elena Ibarz
CJCarlos Javierre
Carlos Javierre
Alfonso Fernández-CanteliAlfonso Fernández-Canteli
Alfonso Fernández-Canteli
LGLuis Gracia
Luis Gracia
In this work a nonlinear phenomenological visco-hyperelastic model including damage consideration is developed to simulate the behavior of Santoprene 101-73 material. This type of elastomeric material is widely used in the automotive and aeronautic sectors, as it has multiple advantages. However, there are still challenges in properly analyzing the mechanical phenomena that these materials exhibit. To simulate this kind of material a lot of theories have been exposed, but none of them have been endorsed unanimously. In this paper, a new model is presented based on the literature, and on experimental data. The test samples were extracted from an air intake duct component of an automotive engine. Inelastic phenomena such as hyperelasticity, viscoelasticity and damage are considered singularly in this model, thus modifying and improving some relevant models found in the literature. Optimization algorithms were used to find out the model parameter values that lead to the best fit of the experimental curves from the tests. An adequate fitting was obtained for the experimental results of a cyclic uniaxial loading of Santoprene 101-73.