Giacomo Gadda

Giacomo Gadda


Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 February 2021 in Scientific Reports
Verified
Journal Article
Open access
PDF file
PMParvin Mohammadyari
Parvin Mohammadyari
GGGiacomo Gadda
Giacomo Gadda
ATAngelo Taibi
Angelo Taibi
Cardiovascular haemodynamics alters during posture changes and exposure to microgravity. Vascular auto-remodelling observed in subjects living in space environment causes them orthostatic intolerance when they return on Earth. In this study we modelled the human haemodynamics with focus on head and neck exposed to different hydrostatic pressures in supine, upright (head-up tilt), head-down tilt position, and microgravity environment by using a well-developed 1D-0D haemodynamic model. The model consists of two parts that simulates the arterial (1D) and brain-venous (0D) vascular tree. The cardiovascular system is built as a network of hydraulic resistances and capacitances to properly model physiological parameters like total peripheral resistance, and to calculate vascular pressure and the related flow rate at any branch of the tree. The model calculated 30.0 mmHg (30%), 7.1 mmHg (78%), 1.7 mmHg (38%) reduction in mean blood pressure, intracranial pressure and central venous pressure after posture change from supine to upright, respectively. The modelled brain drainage outflow percentage from internal jugular veins is 67% and 26% for supine and upright posture, while for head-down tilt and microgravity is 65% and 72%, respectively. The model confirmed the role of peripheral veins in regional blood redistribution during posture change from supine to upright and microgravity environment as hypothesized in literature. The model is able to reproduce the known haemodynamic effects of hydraulic pressure change and weightlessness. It also provides a virtual laboratory to examine the consequence of a wide range of orthostatic stresses on human haemodynamics.

18 December 2021 in Diagnostics
Verified
Journal Article
Open access
PDF file
Antonino ProtoAntonino Proto
Antonino Proto
Daniele ContiDaniele Conti
Daniele Conti
Erica MenegattiErica Menegatti
Erica Menegatti
ATAngelo Taibi
Angelo Taibi
GGGiacomo Gadda
Giacomo Gadda
Cerebral venous outflow is investigated in the diagnosis of heart failure through the monitoring of jugular venous pulse, an indicator to assess cardiovascular diseases. The jugular venous pulse is a weak signal stemming from the lying internal jugular vein and often invasive methodologies requiring surgery are mandatory to detect it. Jugular venous pulse can also be extrapolated via the ultrasound technique, but it requires a qualified healthcare operator to perform the examination. In this work, a wireless, user-friendly, wearable device for plethysmography is developed to investigate the possibility of monitoring the jugular venous pulse non-invasively. The proposed device can monitor the jugular venous pulse and the electrocardiogram synchronously. To study the feasibility of using the proposed device to detect physiological variables, several measurements were carried out on healthy subjects by considering three different postures: supine, sitting, and upright. Data acquired in the experiment were properly filtered to highlight the cardiac oscillation and remove the breathing contribution, which causes a considerable shift in the amplitude of signals. To evaluate the proper functioning of the wearable device for plethysmography, a comparison with the ultrasound technique was carried out. As a satisfactory result, the acquired signals resemble the typical jugular venous pulse waveforms found in literature.

25 May 2017 in American Journal of Neuroradiology
Verified
Journal Article
Open access
PDF file
SSS.K. Sethi
S.K. Sethi
ADAna M Daugherty
Ana M Daugherty
GGGiacomo Gadda
Giacomo Gadda
DUD.T. Utriainen
D.T. Utriainen
JJJ. Jiang
J. Jiang
EHEwart Mark Haacke
Ewart Mark Haacke
BACKGROUND AND PURPOSE: To date, research on extracranial venous collaterals has been focused on structure, with relatively little attention paid to hemodynamics. We addressed this limitation by quantitatively comparing collateral flow in patients with multiple sclerosis and healthy controls by using phase-contrast MR imaging. We hypothesize that patients with MS with structurally anomalous internal jugular veins will have elevated collateral venous flow compared with healthy controls. MATERIALS AND METHODS: The sample consisted of 276 patients with MS and 106 healthy controls. We used MRV to classify internal jugular veins as stenotic and nonstenotic based on an absolute cross-sectional area threshold in 276 patients with MS and 60 healthy controls; 46 healthy controls lacked this imaging. Individual and total vessel flows were quantified by using phase-contrast MR imaging on all patients. Veins were classified by extracranial drainage type: internal jugular veins (I), paraspinal (II), and superficial (III). Differences among healthy controls, patients with MS, nonstenotic patients, and stenotic subgroups in total venous flow by vessel type were evaluated in a general linear model for statistical analysis. RESULTS: In the MS group, 153 patients (55%) evidenced stenosis, whereas 12 (20%) healthy controls were classified as stenotic (P < .001). Compared with healthy controls, the MS group showed lower type I flow and increased type II flow. Stenosis was associated with reduced flow in the type I vessels [F(1272) = 68; P < .001]. The stenotic MS group had increased flow in the type II vessels compared with the nonstenotic MS group [F(1272) = 67; P < .001]. CONCLUSIONS: Compared with healthy controls, patients with MS exhibit reduced venous flow in the main extracerebral drainage vein (internal jugular vein). In contrast, flow in the paraspinal venous collaterals is elevated in patients with MS and exacerbated by venous stenosis. Collateral drainage may be a compensatory response to internal jugular vein flow reduction.

21 July 2016 in American Journal of Neuroradiology
Verified
Journal Article
Open access
PDF file
GGGiacomo Gadda
Giacomo Gadda
ATAngelo Taibi
Angelo Taibi
FSF. Sisini
F. Sisini
MGM. Gambaccini
M. Gambaccini
SSS.K. Sethi
S.K. Sethi
Mauro UrsinoMauro Ursino
Mauro Ursino
BACKGROUND AND PURPOSE: A comprehensive parameter model was developed to investigate correlations between cerebral hemodynamics and alterations in the extracranial venous circulation due to posture changes and/or extracranial venous obstruction (stenosis). The purpose of this work was to validate the simulation results by using MR imaging and echo-color Doppler experimental blood flow data in humans. MATERIALS AND METHODS: To validate the model outcomes, we used supine average arterial and venous extracerebral blood flow, obtained by using phase-contrast MR imaging from 49 individuals with stenosis in the acquisition plane at the level of the disc between the second and third vertebrae of the left internal jugular vein, 20 with stenosis in the acquisition plane at the level of the disc between the fifth and sixth vertebrae of the right internal jugular vein, and 38 healthy controls without stenosis. Average data from a second group of 10 healthy volunteers screened with an echo-color Doppler technique were used to evaluate flow variations due to posture change. RESULTS: There was excellent agreement between experimental and simulated supine flows. Every simulated CBF fell inside the standard error from the corresponding average experimental value, as well as most of the simulated extracerebral arterial flow (extracranial blood flow from the head and face, measured at the level of the disc between second and third vertebrae) and venous flows. Simulations of average jugular and vertebral blood flow variations due to a change of posture from supine to upright also matched the experimental data. CONCLUSIONS: The good agreement between simulated and experimental results means that the model can correctly reproduce the main factors affecting the extracranial circulation and could be used to study other types of stenotic conditions not represented by the experimental data.

8 August 2021 in Medical & Biological Engineering & Computing
Verified
Journal Article
Open access
PDF file
GGGiacomo Gadda
Giacomo Gadda
SCSirio Cocozza
Sirio Cocozza
MGMauro Gambaccini
Mauro Gambaccini
ATAngelo Taibi
Angelo Taibi
ETEnrico Tedeschi
Enrico Tedeschi
Giuseppe PalmaGiuseppe Palma
Giuseppe Palma
Accurate and reproducible measurement of blood flow profile is very important in many clinical investigations for diagnosing cardiovascular disorders. Given that many factors could affect human circulation, and several parameters must be set to properly evaluate blood flows with phase-contrast techniques, we developed an MRI-compatible hydrodynamic phantom to simulate different physiological blood flows. The phantom included a programmable hydraulic pump connected to a series of pipes immersed in a solution mimicking human soft tissues, with a blood-mimicking fluid flowing in the pipes. The pump is able to shape and control the flow by driving a piston through a dedicated software. Periodic waveforms are used as input to the pump to move the fluid into the pipes, with synchronization of the MRI sequences to the flow waveforms. A dedicated software is used to extract and analyze flow data from magnitude and phase images. The match between the nominal and the measured flows was assessed, and the scope of phantom variables useful for a reliable calibration of an MRI system was accordingly defined. Results showed that the NO-HYPE phantom is a valuable tool for the assessment of MRI scanners and sequence design for the MR evaluation of blood flows. Graphical

16 March 2020 in European Radiology Experimental
Verified
Journal Article
Open access
PMParvin Mohammadyari
Parvin Mohammadyari
GGGiacomo Gadda
Giacomo Gadda
ATAngelo Taibi
Angelo Taibi
JMJosep Munuera
Josep Munuera
Background: Congenital vascular disease is one of the leading causes of death in paediatric age. Despite the importance of paediatric haemodynamics, large investigations have been devoted to the evaluation of circulation in adults. The novelty of this study consists in the development of a well calibrated mathematical model of cardiovascular circulation in paediatric subjects. To reach the purpose, a model for adult circulation was modified and recalibrated with experimental data and literature from children to be able to calculate the flow rates and pressures in the brain and neck. Methods: The haemodynamic model simulates the 76 main arteries, together with the main veins in brain and neck. A proper magnetic resonance imaging (MRI) dataset of 29 volunteers aged 12 ± 5 years (mean ± standard deviation) was used to extract age-dependent physiological and clinical parameters such as heart rate, flow rate, vessel cross section area, and blood pressure. The computational model was calibrated using such experimental data. The paediatric and adult model results were compared. Results: Increase of the vessels stiffness due to aging contributes to a flow rate decrease while blood pressure increases. In accordance, our simulation results show about 16% decrease in mean pressure of internal jugular vein in paediatric rather than adult subjects. The model outcomes indicated about 88% correlation with MRI data. Conclusions: The mathematical model simulates the paediatric head and neck blood circulation. The model provides detailed information of human haemodynamics including arterial and venous network to study both paediatric and adult blood circulation.