Angelo Taibi

Prof. Angelo Taibi

orcid

Research Focus & Metrics

Academic Career Length

33Years (1994-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 March 2012 in Journal of Applied Physiology
Verified
Journal Article
Closed access
PZPaolo Zamboni
Paolo Zamboni
EMErica Menegatti
Erica Menegatti
LPLuca Pomidori
Luca Pomidori
SMSandra Morovic
Sandra Morovic
ATAngelo Taibi
Angelo Taibi
MGMauro Gambaccini
Mauro Gambaccini
We assessed the hemodynamic effects induced by the thoracic pump in the intra- and extracranial veins of the cerebral venous system on healthy volunteers. Activation of the thoracic pump was standardized among subjects by setting the deep inspiration at 70% of individual vital capacity. Peak velocity (PV), time average velocity (TAV), vein area (VA), and flow quantification (Q) were assessed by means of echo color Doppler in supine posture. Deep respiration significantly increases PV, TAV, and Q, but it is limited to the extracranial veins. To the contrary, no significant hemodynamic changes were recorded at the level of the intracranial venous network. Moreover, at rest TAV in the jugular veins was significantly correlated with Q of the intracranial veins. We conclude that the modulation of the atmospheric pressure operated by the thoracic pump significantly modifies the hemodynamics of the jugular veins and of the reservoir of the neck and facial veins, with no effect on the vein network of the intracranial compartment.

1 December 2018 in Physics in Medicine & Biology
Verified
Journal Article
Open access
PDF file
LBLUCA BROMBAL
LUCA BROMBAL
Sandro DonatoSandro Donato
Sandro Donato
DDDiego Dreossi
Diego Dreossi
FAFulvia Arfelli
Fulvia Arfelli
DBDeborah Bonazza
Deborah Bonazza
RLRenata Longo
Renata Longo
X-ray phase imaging has the potential to dramatically improve soft tissue contrast sensitivity, which is a crucial requirement in many diagnostic applications such as breast imaging. In this context, a program devoted to perform in vivo phase-contrast synchrotron radiation breast computed tomography is ongoing at the Elettra facility (Trieste, Italy). The used phase-contrast technique is the propagation-based configuration, which requires a spatially coherent source and a sufficient object-to-detector distance. In this work the effect of this distance on image quality is quantitatively investigated scanning a large breast surgical specimen at three object-to-detector distances (1.6, 3, 9 m) and comparing the images both before and after applying the phase-retrieval procedure. The sample is imaged at 30 keV with a pixel pitch CdTe single-photon-counting detector, positioned at a fixed distance of 31.6 m from the source. The detector fluence is kept constant for all acquisitions. The study shows that, at the largest distance, a 20-fold SNR increase can be obtained by applying the phase-retrieval procedure. Moreover, it is shown that, for phase-retrieved images, changing the object-to-detector distance does not affect spatial resolution while boosting SNR (four-fold increase going from the shortest to the largest distance). The experimental results are supported by a theoretical model proposed by other authors, whose salient results are presented in this paper.

11 July 2013 in BMC Neurology
Verified
Journal Article
Open access
PDF file
Paolo ZamboniPaolo Zamboni
Paolo Zamboni
FSFrancesco Sisini
Francesco Sisini
EMErica Menegatti
Erica Menegatti
ATAngelo Taibi
Angelo Taibi
AMAnna Maria Malagoni
Anna Maria Malagoni
MGMauro Gambaccini
Mauro Gambaccini
The quantification of the flow returning from the head through the cervical veins and the collaterals of the internal jugular vein (IJV), is becoming of prominent interest in clinical practice. We developed a novel model to calculate the cerebral venous return, normalized to the arterial inflow, in the different segments of the IJV. We assessed, by established Echo Colour Doppler (ECD) methodology, the head inflow (HBinF) defined as the sum of common carotids and vertebral arteries, as well as the cerebral flow (CBF) defined as the sum of internal carotid and vertebral arteries. We also assessed the head outflow (HBoutF) defined as the sum of the measurements at the junction of the IJV and the vertebral veins. In addition, we also calculated the collateral flow index (CFI) by estimating the flow which re-enters directly into the superior vena cava as the amount of blood extrapolated by the difference between the HBinF and the HBoutF. We preliminarily tested the model by comparing ten healthy controls (HC) with ten patients affected by chronic cerebral spinal venous insufficiency (CCSVI), a condition characterized by some blockages in the IJV which are bypassed by collateral circulation. In HC the HBinF was 956+-105ml/min, whereas the HBoutF was > 90% of the HBinF, leading to a final CFI value of 1%. The last result shows that a very small amount of blood is drained by the collaterals. In upright we confirmed a reduction of the outflow through the IJV which increased CFI to 9%. When we applied the model to CCSVI, the HBinF was not significantly different from controls. In supine, the flow of CCSVI patients in the IJV junction was significantly lower (p < 0.001) while the correspondent CFI value significantly increased (61%, p < 0.0002). Our preliminary application of the novel model in the clinical setting suggests the pivotal role of the collateral network in draining the blood into the superior vena cava under CCSVI condition.

1 February 2015 in American Journal of Physiology-Heart and Circulatory Physiology
Verified
Journal Article
Open access
PDF file
GGGiacomo Gadda
Giacomo Gadda
ATAngelo Taibi
Angelo Taibi
FSFrancesco Sisini
Francesco Sisini
MGMauro Gambaccini
Mauro Gambaccini
PZPaolo Zamboni
Paolo Zamboni
Mauro UrsinoMauro Ursino
Mauro Ursino
We developed a mathematical model of the cerebral venous outflow for the simulation of the average blood flows and pressures in the main drainage vessels of the brain. The main features of the model are that it includes a validated model for the simulation of the intracranial circulation and it accounts for the dependence of the hydraulic properties of the jugular veins with respect to the gravity field, which makes it an useful tool for the study of the correlations between extracranial blood redistributions and changes in the intracranial environment. The model is able to simulate the average pressures and flows in different points of the jugular ducts, taking into account the amount of blood coming from the anastomotic connections; simulate how the blood redistribution due to change of posture affects flows and pressures in specific points of the system; and simulate redistributions due to stenotic patterns. Sensitivity analysis to check the robustness of the model was performed. The model reproduces average physiologic behavior of the jugular, vertebral, and cerebral ducts in terms of pressures and flows. In fact, jugular flow drops from ∼11.7 to ∼1.4 ml/s in the passage from supine to standing. At the same time, vertebral flow increases from 0.8 to 3.4 ml/s, while cerebral blood flow, venous sinuses pressure, and intracranial pressure are constant around the average value of 12.5 ml/s, 6 mmHg, and 10 mmHg, respectively. All these values are in agreement with literature data.

8 May 2014 in Journal of Chemistry
Verified
Journal Article
Open access
PDF file
Alessandra BoschiAlessandra Boschi
Alessandra Boschi
LUL. Uccelli
L. Uccelli
MPM. Pasquali
M. Pasquali
Adriano DuattiAdriano Duatti
Adriano Duatti
ATAngelo Taibi
Angelo Taibi
JEJuan Esposito
Juan Esposito
The188Re radioisotope represents a useful radioisotope for the preparation of radiopharmaceuticals for therapeutic applications, particularly because of its favorable nuclear properties. The nuclide decay pattern is through the emission of a principle beta particle having 2.12 MeV maximum energy, which is enough to penetrate and destroy abnormal tissues, and principle gamma rays (Eγ=155 keV), which can efficiently be used for imaging and calculations of radiation dose.188Re may be conveniently produced by188W/188Re generator systems. The challenges related to the double neutron capture reaction route to provide only modest yield of the parent188W radionuclide indeed have been one of the major issues about the use of188Re in nuclear medicine. Since the specific activity of188W used in the generator is relatively low (<185 GBq/g), the elutedRe188O4-can have a low radioactive concentration, often ineffective for radiopharmaceutical preparation. However, several efficient postelution concentration techniques have been developed, which yield clinically usefulRe188O4-solutions. This review summarizes the technologies developed for the preparation of188W/188Re generators, postelution concentration of the188Re perrhenate eluate, and a brief discussion of new chemical strategies available for the very high yield preparation of188Re radiopharmaceuticals.

8 August 2006 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
PBP Baldelli
P Baldelli
ABA Bravin
A Bravin
CMC Di Maggio
C Di Maggio
GGGisella Gennaro
Gisella Gennaro
ASA Sarnelli
A Sarnelli
MGM Gambaccini
M Gambaccini
Early manifestation of breast cancer is often very subtle and is displayed in a complex and variable pattern of normal anatomy that may obscure the disease. The use of dual-energy techniques, that can remove the structural noise, and contrast media, that enhance the region surrounding the tumour, could help us to improve the detectability of the lesions. The aim of this work is to investigate the use of an iodine-based contrast medium in mammography with two different double exposure techniques: K-edge subtraction mammography and temporal subtraction mammography. Both techniques have been investigated by using an ideal source, like monochromatic beams produced at a synchrotron radiation facility and a clinical digital mammography system. A dedicated three-component phantom containing cavities filled with different iodine concentrations has been developed and used for measurements. For each technique, information about the minimum iodine concentration, which provides a significant enhancement of the detectability of the pathology by minimizing the risk due to high dose and high concentration of contrast medium, has been obtained. In particular, for cavities of 5 and 8 mm in diameter filled with iodine solutions, the minimum concentration needed to obtain a contrast-to-noise ratio of 5 with a mean glandular dose of 2 mGy has been calculated. The minimum concentrations estimated with monochromatic beams and K-edge subtraction mammography are 0.9 mg ml(-1) and 1.34 mg ml(-1) for the biggest and smallest details, respectively, while for temporal subtraction mammography they are 0.84 mg ml(-1) and 1.31 mg ml(-1). With the conventional clinical system the minimum concentrations for the K-edge subtraction mammography are 4.13 mg ml(-1) (8 mm diameter) and 5.75 mg ml(-1) (5 mm diameter), while for the temporal subtraction mammography they are 1.01 mg ml(-1) (8 mm diameter) and 1.57 mg ml(-1) (5 mm diameter).