YITZHAK MENDELSON

Dr. YITZHAK MENDELSON


Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 July 2011 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Closed access
CSChristopher G. Scully
Christopher G. Scully
JLJinseok Lee
Jinseok Lee
JMJoseph Meyer
Joseph Meyer
AGAlexander M. Gorbach
Alexander M. Gorbach
DGDomhnull Granquist-Fraser
Domhnull Granquist-Fraser
KCKi Chon
Ki Chon
We show that a mobile phone can serve as an accurate monitor for several physiological variables, based on its ability to record and analyze the varying color signals of a fingertip placed in contact with its optical sensor. We confirm the accuracy of measurements of breathing rate, cardiac R-R intervals, and blood oxygen saturation, by comparisons to standard methods for making such measurements (respiration belts, ECGs, and pulse-oximeters, respectively). Measurement of respiratory rate uses a previously reported algorithm developed for use with a pulse-oximeter, based on amplitude and frequency modulation sequences within the light signal. We note that this technology can also be used with recently developed algorithms for detection of atrial fibrillation or blood loss.

23 December 2015 in Sensors
Verified
Journal Article
Open access
PDF file
SSS M A Salehizadeh
S M A Salehizadeh
DDDuy Dao
Duy Dao
JBJeffrey Bolkhovsky
Jeffrey Bolkhovsky
CCChae Ho Cho
Chae Ho Cho
YMYITZHAK MENDELSON
YITZHAK MENDELSON
KCKi Chon
Ki Chon
Accurate estimation of heart rates from photoplethysmogram (PPG) signals during intense physical activity is a very challenging problem. This is because strenuous and high intensity exercise can result in severe motion artifacts in PPG signals, making accurate heart rate (HR) estimation difficult. In this study we investigated a novel technique to accurately reconstruct motion-corrupted PPG signals and HR based on time-varying spectral analysis. The algorithm is called Spectral filter algorithm for Motion Artifacts and heart rate reconstruction (SpaMA). The idea is to calculate the power spectral density of both PPG and accelerometer signals for each time shift of a windowed data segment. By comparing time-varying spectra of PPG and accelerometer data, those frequency peaks resulting from motion artifacts can be distinguished from the PPG spectrum. The SpaMA approach was applied to three different datasets and four types of activities: (1) training datasets from the 2015 IEEE Signal Process. Cup Database recorded from 12 subjects while performing treadmill exercise from 1 km/h to 15 km/h; (2) test datasets from the 2015 IEEE Signal Process. Cup Database recorded from 11 subjects while performing forearm and upper arm exercise. (3) Chon Lab dataset including 10 min recordings from 10 subjects during treadmill exercise. The ECG signals from all three datasets provided the reference HRs which were used to determine the accuracy of our SpaMA algorithm. The performance of the SpaMA approach was calculated by computing the mean absolute error between the estimated HR from the PPG and the reference HR from the ECG. The average estimation errors using our method on the first, second and third datasets are 0.89, 1.93 and 1.38 beats/min respectively, while the overall error on all 33 subjects is 1.86 beats/min and the performance on only treadmill experiment datasets (22 subjects) is 1.11 beats/min. Moreover, it was found that dynamics of heart rate variability can be accurately captured using the algorithm where the mean Pearson’s correlation coefficient between the power spectral densities of the reference and the reconstructed heart rate time series was found to be 0.98. These results show that the SpaMA method has a potential for PPG-based HR monitoring in wearable devices for fitness tracking and health monitoring during intense physical activities.

1 August 2006
Verified
Conference Paper
Closed access
YMYITZHAK MENDELSON
YITZHAK MENDELSON
RDR. J. Duckworth
R. J. Duckworth
GCG. Comtois
G. Comtois
To save life, casualty care requires that trauma injuries are accurately and expeditiously assessed in the field. This paper describes the initial bench testing of a wireless wearable pulse oximeter developed based on a small forehead mounted sensor. The battery operated device employs a lightweight optical reflectance sensor and incorporates an annular photodetector to reduce power consumption. The system also has short range wireless communication capabilities to transfer arterial oxygen saturation (SpO2), heart rate (HR), body acceleration, and posture information to a PDA. It has the potential for use in combat casualty care, such as for remote triage, and by first responders, such as firefighters

5 August 2014 in Annals of Biomedical Engineering
Verified
Journal Article
Closed access
PDF file
JCJo Woon Chong
Jo Woon Chong
DDDuy K. Dao
Duy K. Dao
SSS M A Salehizadeh
S M A Salehizadeh
DMDavid D. McManus
David D. McManus
CDChad E. Darling
Chad E. Darling
YMYITZHAK MENDELSON
YITZHAK MENDELSON

14 May 2014 in Annals of Biomedical Engineering
Verified
Journal Article
Closed access
PDF file
SSS. M. A. Salehizadeh
S. M. A. Salehizadeh
DDDuy K. Dao
Duy K. Dao
JCJo Woon Chong
Jo Woon Chong
DMDavid McManus
David McManus
CDChad Darling
Chad Darling
KCKi Chon
Ki Chon

7 March 2016 in Sensors
Verified
Journal Article
Open access
PDF file
KWKristen Warren
Kristen Warren
JHJoshua Harvey
Joshua Harvey
KCKi Chon
Ki Chon
YMYITZHAK MENDELSON
YITZHAK MENDELSON
Photoplethysmographic (PPG) waveforms are used to acquire pulse rate (PR) measurements from pulsatile arterial blood volume. PPG waveforms are highly susceptible to motion artifacts (MA), limiting the implementation of PR measurements in mobile physiological monitoring devices. Previous studies have shown that multichannel photoplethysmograms can successfully acquire diverse signal information during simple, repetitive motion, leading to differences in motion tolerance across channels. In this paper, we investigate the performance of a custom-built multichannel forehead-mounted photoplethysmographic sensor under a variety of intense motion artifacts. We introduce an advanced multichannel template-matching algorithm that chooses the channel with the least motion artifact to calculate PR for each time instant. We show that for a wide variety of random motion, channels respond differently to motion artifacts, and the multichannel estimate outperforms single-channel estimates in terms of motion tolerance, signal quality, and PR errors. We have acquired 31 data sets consisting of PPG waveforms corrupted by random motion and show that the accuracy of PR measurements achieved was increased by up to 2.7 bpm when the multichannel-switching algorithm was compared to individual channels. The percentage of PR measurements with error ≤ 5 bpm during motion increased by 18.9% when the multichannel switching algorithm was compared to the mean PR from all channels. Moreover, our algorithm enables automatic selection of the best signal fidelity channel at each time point among the multichannel PPG data.