Ki Chon

Dr. Ki Chon


Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 2012 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Closed access
CSC. G. Scully
C. G. Scully
JLJinseok Lee
Jinseok Lee
JMJ. Meyer
J. Meyer
AGA. M. Gorbach
A. M. Gorbach
DGD. Granquist-Fraser
D. Granquist-Fraser
KCKi Chon
Ki Chon
We show that a mobile phone can serve as an accurate monitor for several physiological variables, based on its ability to record and analyze the varying color signals of a fingertip placed in contact with its optical sensor. We confirm the accuracy of measurements of breathing rate, cardiac R-R intervals, and blood oxygen saturation, by comparisons to standard methods for making such measurements (respiration belts, ECGs, and pulse-oximeters, respectively). Measurement of respiratory rate uses a previously reported algorithm developed for use with a pulse-oximeter, based on amplitude and frequency modulation sequences within the light signal. We note that this technology can also be used with recently developed algorithms for detection of atrial fibrillation or blood loss.

5 August 2014 in Annals of Biomedical Engineering
Verified
Journal Article
Closed access
PDF file
JCJo Woon Chong
Jo Woon Chong
DDDuy K. Dao
Duy K. Dao
SSS M A Salehizadeh
S M A Salehizadeh
DMDavid D. McManus
David D. McManus
CDChad E. Darling
Chad E. Darling
YMYITZHAK MENDELSON
YITZHAK MENDELSON

23 November 2013 in Annals of Biomedical Engineering
Verified
Journal Article
Closed access
PDF file
YNYunyoung Nam
Yunyoung Nam
JLJinseok Lee
Jinseok Lee
KCKi Chon
Ki Chon

14 May 2014 in Annals of Biomedical Engineering
Verified
Journal Article
Closed access
PDF file
SSS. M. A. Salehizadeh
S. M. A. Salehizadeh
DDDuy K. Dao
Duy K. Dao
JCJo Woon Chong
Jo Woon Chong
DMDavid McManus
David McManus
CDChad Darling
Chad Darling
KCKi Chon
Ki Chon

30 July 2014 in Sensors
Verified
Journal Article
Open access
PDF file
BRBersain Reyes
Bersain Reyes
Natasa ReljinNatasa Reljin
Natasa Reljin
KCKi Chon
Ki Chon
Tracheal sounds have received a lot of attention for estimating ventilation parameters in a non-invasive way. The aim of this work was to examine the feasibility of extracting accurate airflow, and automating the detection of breath-phase onset and respiratory rates all directly from tracheal sounds acquired from an acoustic microphone connected to a smartphone. We employed the Samsung Galaxy S4 and iPhone 4s smartphones to acquire tracheal sounds from N = 9 healthy volunteers at airflows ranging from 0.5 to 2.5 L/s. We found that the amplitude of the smartphone-acquired sounds was highly correlated with the airflow from a spirometer, and similar to previously-published studies, we found that the increasing tracheal sounds’ amplitude as flow increases follows a power law relationship. Acquired tracheal sounds were used for breath-phase onset detection and their onsets differed by only 52 ± 51 ms (mean ± SD) for Galaxy S4, and 51 ± 48 ms for iPhone 4s, when compared to those detected from the reference signal via the spirometer. Moreover, it was found that accurate respiratory rates (RR) can be obtained from tracheal sounds. The correlation index, bias and limits of agreement were r2 = 0.9693, 0.11 (−1.41 to 1.63) breaths-per-minute (bpm) for Galaxy S4, and r2 = 0.9672, 0.097 (–1.38 to 1.57) bpm for iPhone 4s, when compared to RR estimated from spirometry. Both smartphone devices performed similarly, as no statistically-significant differences were found.

1 July 2012 in Anesthesia & Analgesia
Verified
Journal Article
Closed access
CSChristopher G. Scully
Christopher G. Scully
NSNandakumar Selvaraj
Nandakumar Selvaraj
FRFrederick W. Romberg
Frederick W. Romberg
RWRicha Wardhan
Richa Wardhan
JRJohn Ryan
John Ryan
KCKi Chon
Ki Chon
Ng rate frequency band before significant changes occurred in heart rate or arterial blood pressure. We also identified the best PPG probe site for early detection of blood volume loss by testing ear, finger, and forehead sites. METHODS: Eight subjects had 900 mL of blood withdrawn followed by reinfusion of 900 mL of blood. Physiological monitoring included PPG waveforms from ear, finger, and forehead probe sites, standard electrocardiogram, and standard blood pressure cuff measurements. The time-varying amplitude sequences in the heart rate frequency band and breathing rate frequency band present in the PPG waveform were extracted from high-resolution time-frequency spectra. These amplitudes were used as a parameter for blood loss detection. RESULTS: Heart rate and arterial blood pressure did not significantly change during the protocol. Using time-frequency analysis of the PPG waveform from ear, finger, and forehead probe sites, the amplitude signal extracted at the frequency corresponding to the heart rate significantly decreased when 900 mL of blood was withdrawn, relative to baseline (all P < 0.05); for the ear, the corresponding signal decreased when only 300 mL of blood was withdrawn. The mean percent decrease in the amplitude of the heart rate component at 900 mL blood loss relative to baseline was 45.2% (38.2%), 42.0% (29.2%), and 42.3% (30.5%) for ear, finger, and forehead probe sites, respectively, with the lower 95% confidence limit shown in parentheses. After 900 mL blood reinfusion, the amplitude signal at the heart rate frequency showed a recovery towards baseline. There was a clear separation of amplitude values at the heart rate frequency between baseline and 900 mL blood withdrawal. Specificity and sensitivity were both found to be 87.5% with 95% confidence intervals (47.4%, 99.7%) for ear PPG signals for a chosen threshold value that was optimized to separate the 2 clusters of amplitude values (baseline and blood loss) at the heart rate frequency. Meanwhile, no significant changes in the spectral amplitude in the frequency band corresponding to respiration were found. CONCLUSION: A time-frequency spectral method detected blood loss in spontaneously breathing subjects before the onset of significant changes in heart rate or blood pressure. Spectral amplitudes at the heart rate frequency band were found to significantly decrease during blood loss in spontaneously breathing subjects, whereas those at the breathing rate frequency band did not significantly change. This technique may serve as a valuable tool in intraoperative and trauma settings to detect and monitor hemorrhage....