Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 July 2019 in Materials
Verified
Journal Article
Open access
PDF file
AKAndrzej Książkiewicz
Andrzej Książkiewicz
GDGrzegorz Dombek
Grzegorz Dombek
KNKarol Nowak
Karol Nowak
Contact resistance is an important maintenance parameter for electromagnetic switches, including low-voltage relays. The flow of significant current through electric contacts may influence the contact surface and thus the value of the electric contact resistance (ECR). The change in ECR is influenced not only by the value of current but also by the current phase. Therefore, the impact of the switching short-circuit current’s phase on the ECR was analyzed in this paper. Significant changes in the resistance after each switching cycle were observed. The ECR decreased significantly after each make operation, and a correlation with current amplitude, total let-through energy, and short-circuit time was not observed.

16 October 2019 in Energies
Verified
Journal Article
Open access
PDF file
AKAndrzej Książkiewicz
Andrzej Książkiewicz
GDGrzegorz Dombek
Grzegorz Dombek
KNKarol Nowak
Karol Nowak
JJJerzy Janiszewski
Jerzy Janiszewski
Due to fault currents occurring in electrical installations, high electromagnetic force values may be induced in current paths of low-voltage electromagnetic relays. This force may lead to an electromagnetic bounce that will further result in an electric arc ignition between contacts, and under some circumstances, it will result in contact welding. For the proper exploitation of relays, the threshold value of the maximum current, and thus the electrodynamic force, should be known. This force depends on several factors, including: contact materials, dimensions of relay current paths, relay electromagnetic coil, etc. This paper presents the results of calculations and an experiment on electromagnetic forces, which cover these factors. A static closing force, acting on the contacts, and the fault current were measured. As a result, values of the force and current threshold were obtained, which inform when an electrodynamic bounce may occur. The obtained result may be used in designing contact rivets and relay current paths together with the selection of adequate fault protection devices.

31 March 2021 in Energies
Verified
Journal Article
Open access
PDF file
KNKarol Nowak
Karol Nowak
JJJerzy Janiszewski
Jerzy Janiszewski
GDGrzegorz Dombek
Grzegorz Dombek
This paper presents a method to limit the arc energy and hence the hazard risk category value according to IEEE 1584 by using a system of two oppositely connected multi-sectional thyristor branches. A test circuit for testing the effectiveness of a thyristor arc eliminator was designed and constructed. Arc ignition inside electrical switchgear can be a source of danger for technical personnel. The arc energy calculated according to the algorithms in IEEE 1584 can be significantly reduced by using multi-sectional arc eliminator MSAE. For the actual measuring object, the calculation of the hazardous arc flash zone and the hazard category was carried out for the system not equipped with an arc eliminator, and then the same was performed in a system with an arc eliminator. In parallel, the pressure inside the closed polyvinyl chloride (PVC) electrical box enclosure was measured and then compared with the calculated pressures that could occur during an arc fault. It was found that a Multi-Sectional Arc Eliminator (MSAE) effectively protects devices supplied from low voltage networks against the effects of short circuit or arc fault, such as the sudden increase of gas pressure inside the switchboard, which may cause it to break, significantly reduce the loss of electrode material, limit the spread of hot electrode material outside the switchgear, and also significantly reduces the energy of the electric arc.

18 July 2019 in Energies
Verified
Journal Article
Open access
PDF file
KNKarol Nowak
Karol Nowak
JJJerzy Janiszewski
Jerzy Janiszewski
GDGrzegorz Dombek
Grzegorz Dombek
The paper presents the layout of two opposing thyristors working as an Arc Eliminator (AE). The presented solution makes it possible to protect an electrical apparatus against the effects of an arcing fault. An Arc Eliminator is assumed to be a device cooperating with the protected apparatus. Thyristors were used because of their speed of operation and a relatively lower cost compared to other semiconductors with the same current-carrying capacity. The proposed solution, as one of the few currently available, makes it possible to eliminate the fault arc—both at short-circuit currents and current values to which overcurrent protections do not react. A test circuit was designed and made to study the effectiveness of the thyristor arc eliminator. A series of tests was carried out with variable impedance in the arc branch, including the influence of circuit inductance on arc time. It was found that the thyristor arc eliminator effectively protects devices powered from a low voltage power network against the effects of a fault or arc fault. The correctness of system operation for a wide range of impedance changes in the circuit feeding the arc location was demonstrated.

16 October 2023 in Eksploatacja i Niezawodność – Maintenance and Reliability
Verified
Journal Article
Closed access
AMAlbert Maćkowiak
Albert Maćkowiak
MKMariusz Kostrzewski
Mariusz Kostrzewski
ABArtur Bugała
Artur Bugała
NCNorbert Chamier-Gliszczyński
Norbert Chamier-Gliszczyński
DBDorota Bugała
Dorota Bugała
KNKarol Nowak
Karol Nowak
The paper presents the results related to the simulation of dust-separating tangential cyclones: single cyclones of various geometries, and an axial multi-cyclone with fixed geometries and components. Its goal was to apply low-cost analyses for cyclones in industrial realization. Therefore, the...

30 January 2020 in Energies
Verified
Journal Article
Open access
PDF file
KNKarol Nowak
Karol Nowak
JJJerzy Janiszewski
Jerzy Janiszewski
GDGrzegorz Dombek
Grzegorz Dombek
The paper presents a system of two oppositely connected multi-sectional thyristor branches. The system works as a multi-sectional arc eliminator (MSAE), protecting low-voltage electrical apparatus against the effects of an arcing fault. MSAE is designed to serve as a device cooperating with protected and secured electrical equipment. The use of thyristors in the proposed solution allows to obtain a high speed of operation, while multi-sectional thyristor branches significantly increase the permissible current load of the arc eliminator. A test circuit was designed and made to test the performance effectiveness of the multi-sectional thyristor arc eliminator. A number of tests were carried out with variable current values in the arc branch, taking into account the influence of thyristor conduction voltage and different thyristor gate release times. It was found that the multi-section thyristor arc eliminator system effectively protects devices powered from low voltage power network against the effects of interference or arc fault.