We report the real time characterization and measurement results of a new tri-axial capacitive sensing array. Each unit cell of the Kapton based sensor has an overlapping electrode geometry that allows for the measurement of normal and shear force magnitudes, and the estimation of the 2D and 3D angle of the shear force. The use of a patterned Ecoflex dielectric layer further improves the shear force response and the tunability of the sensor. A custom readout circuit was developed to selectively read the differential capacitances in the sensor array. The local (unit cell) and global (array) force response of the sensor was characterized using a tilt stage, allowing us to determine both the normal and the shear response at different angles in the range of 0-20N. The results show that the Unit Cell response is uniform in the linear range of 0-10N for normal forces (4.6fF/N for all four differential capacitances) and shows good sensitivity for shear forces (1.4 fF/N difference between the right and left differential capacitances at the minimum) and low cross talk. Similar results were seen when a global force was applied across the sensor array. 2D and 3D models were developed to extrapolate the shear force angle from the capacitance data. We also characterized the flexible patterned dielectric layer to understand the effect of its structural dimensions on the effective relative permittivity and developed an analytical model to easily calculate the effective relative permittivity, which showed excellent correlation with the experimentally obtained results. [2020-0382]
We report on polydimethlysiloxane (PDMS) microlenses and microlens arrays on flat and curved substrates fabricated via a relatively simple process combining liquid-phase photopolymerization and a single molding step. The mold for the formation of the PDMS lenses is fabricated by photopolymerizing a polyacrylamide (PAAm) pre-hydrogel. The shrinkage of PAAm after its polymerization forms concave lenses. The lenses are then transferred to PDMS by a single step molding to form PDMS microlens array on a flat substrate. The PAAm concave lenses are also transferred to PDMS and another flexible polymer, Solaris, to realize artificial compound eyes. The resultant microlenses and microlens arrays possess good uniformity and optical properties. The focal length of the lenses is inversely proportional to the shrinkage time. The microlens mold can also be rehydrated to change the focal length of the ultimate PDMS microlenses. The spherical aberration is 2.85 μm and the surface roughness is on the order of 204 nm. The microlenses can resolve 10.10 line pairs per mm (lp/mm) and have an f-number range between f/2.9 and f/56.5. For the compound eye, the field of view is 113°.
We developed an ankle-worn gait monitoring system for tracking gait parameters, including length, width, and height. The system utilizes ankle bracelets equipped with wide-angle infrared (IR) stereo cameras tasked with monitoring a marker on the opposing ankle. A computer vision algorithm we have also developed processes the imaged marker positions to estimate the length, width, and height of the person’s gait. Through testing on multiple participants, the prototype of the proposed gait monitoring system exhibited notable performance, achieving an average accuracy of 96.52%, 94.46%, and 95.29% for gait length, width, and height measurements, respectively, despite distorted wide-angle images. The OptiGait system offers a cost-effective and user-friendly alternative compared to existing gait parameter sensing systems, delivering comparable accuracy in measuring gait length and width. Notably, the system demonstrates a novel capability in measuring gait height, a feature not previously reported in the literature.
Glaucoma is a group of characteristic optic neuropathies that collectively are the leading cause of irreversible blindness globally. Elevated intraocular pressure (IOP) is the major causal risk factor. While the fundamental mechanisms of the IOP elevation and consequent optic neuropathy are not well understood, recent studies have indicated that there may be pressure spikes directed at the optic nerve head during accommodation, and that IOP may not be homogeneous throughout the eye. To facilitate the $in\ situ$ and $in\ vivo$ measurement of IOP in various locations within the vitreous and facilitate measurement of accommodative IOP spikes at the ONH, here we report the development of an implantable, biocompatible, and miniaturized IOP sensor using two-dimensional plasmonic grating that generates structural color. The change of the grating period with pressure between 0 and 50 mmHg results in a change in the visible color, allowing us to observe small changes in pressure without additional electronics.
Commercially available biomedical wearable sensors to measure tensile force/strain still struggle with miniaturization in terms of weight, size, and conformability. Flexible and epidermal electronic devices have been utilized in these applications to overcome these issues. However, current sensors still require a power supply and some form of powered data transfer, which present challenges to miniaturization and to applications. Here, we report on the development of flexible, passive (thus zero power consumption), and biocompatible nanostructured photonic devices that can measure tensile strain in real time by providing an optical readout instead of an electronic readout. Hierarchical silver (Ag) nanostructures in various thicknesses of 20–60 nm were fabricated and embedded on a stretchable substrate using e-beam lithography and a low-temperature dewetting process. The hierarchical Ag nanostructures offer more design flexibility through a two-level design approach. A tensional force applied in one lateral (x- or y-) direction of the stretchable substrate causes a Poisson contraction in the other, and as a result, a shift in the reflected light of the nanostructures. A clear blue shift of more than 100 nm in peak reflectance in the visible spectrum was observed in the reflected color, making the devices applicable in a variety of biomedical photonic sensing applications.