In this study a 3-D finite element analysis for cantilever plate structure excited by giving unit deflection at free end is presented. Finite Element Modeling based on ANSYS12.0 package using modal analysis and harmonic analysis is used in this study for cantilever plate structure by patch type of piezoelectric plates of PZT-5H4E as a piezo material and steel as a substrate material for Cantilever Beam. This study aims to investigate the influence of different geometry parameters like, length and width & position of piezo patches on voltage generation & try to find out optimal geometrical dimensions of piezoelectric beam for maximum energy harvesting. ANSYS-12.0 is used as optimization tool. Here the basic modeling with an equivalent circuit is done initially by considering some specific dimensions of beam. Then simulation of the same is done by varying different geometrical parameters where effect of change in length of piezo patch is analyzed first .The second affecting parameter considered is change in Width of piezo patch and last one is the position of piezo patch along the length of beam is analyzed, where output is measured in turn of voltage generated. This study aims to investigate the Optimum placement of piezoelectric actuators in a cantilever beam for maximum energy harvesting.
In recent years, micro electro-mechanical system (MEMS)-based biomedical devices have been investigated by various researchers for biomedicine, disease diagnosis, and liquid drug delivery. The micropump based devices are of considerable significance for accurate drug delivery and disease diagnosis. In the present study, design aspects of the piezoelectric actuated micropump used for extraction of blood sample are presented. A pentagonal microneedle, which is an integral part of the micropump, was used to extract the blood volume. The blood was then delivered to the biosensor, located in the pump chamber, for diagnosis. The purpose of such low-powered devices is to get sufficient blood volume for the diagnostic purpose at the biosensor located within the pump chamber, with a minimum time of actuation, which will eventually cause less pain. ANSYS® simulations were performed on four quarter piezoelectric bimorph actuator (FQPB) at 2.5 volts. The modal and harmonic analysis were carried out with various load conditions for FQPB. The extended microneedle lengths inside the pump chamber showed improved flow characteristics. Enhanced volume flow rate of 1.256 µL/s was obtained at 22,000 Hz applied frequency at the biosensor location.
The purpose of this study is to design a patient-specific TMJ implant and study its behaviour under different loading conditions compared with natural intact TMJ. There are several diseases, which affect the proper growth and function of TMJ, and in some cases, TMJ injury results from accidents. To repair the TMJ, temporomandibular joint replacement or TJR surgery is performed. In this work, CT-scan data of the skull and mandible region with broken condylar head were used to study the biomechanical behaviour of the intact mandible and customized TMJ prostheses in order to design a patient-specific total TMJ implant. The customized TMJ implant was virtually studied under simulated loading conditions using finite element method (FEM) in ANSYS Workbench and then compared to the intact jaw-mandible for the combinations of two different biocompatible material models. It is observed that the natural TMJ has a higher deformation value as compared to the patient-specific TMJ implant due to the lower mechanical strength of bone relative to the Ti-6Al-4V and Co-Cr alloy. Hence, we can conclude that the designed custom TMJ implant is safe for the patient from the point of design perspective.
A computational and experimental approach to modeling oscillations of a new axial-type piezoelectric generator (PEG) with an attached mass and an active base is considered. A pair of cylindrical piezoelements located along the generator axis is used as an active base. Plate-type piezoelectric elements, made in the form of two bimorphs on an elastic PEG base, use the potential energy of PEG bending vibrations. Energy generation in cylindrical piezoelectric elements occurs due to the transfer of compressive forces to the piezoelectric element at the base of the PEG during excitation of structural vibrations. The active load scheme is selected separately for each piezoelectric element. Numerical simulation was performed in the ANSYS FE analysis package. The results of modal and harmonic analysis of vibrations are presented. A technique for experimental analysis of vibrations is presented, and a laboratory test setup is described. Numerical and experimental results are presented for the output characteristics of a piezoelectric generator at a low-frequency load. For one of the versions of the generator and a certain displacement amplitude for a frequency of 39 Hz, in the results of a comparative experimental analysis at a load of 10 kΩ, the maximum output power for each cylindrical piezoelectric element was 2138.9 μW, and for plate-type piezoelectric elements, respectively, 446.9 μW and 423.2 μW.