Anubhav Tiwari

Mr. Anubhav Tiwari

orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 March 2022 in Applied Sciences
Verified
Journal Article
Open access
PDF file
ATAnubhav Tiwari
Anubhav Tiwari
Vijay Kumar GuptaVijay Kumar Gupta
Vijay Kumar Gupta
RHRakesh Kumar Haldkar
Rakesh Kumar Haldkar
Ivan A. ParinovIvan A. Parinov
Ivan A. Parinov
The purpose of this study is to design a patient-specific TMJ implant and study its behaviour under different loading conditions compared with natural intact TMJ. There are several diseases, which affect the proper growth and function of TMJ, and in some cases, TMJ injury results from accidents. To repair the TMJ, temporomandibular joint replacement or TJR surgery is performed. In this work, CT-scan data of the skull and mandible region with broken condylar head were used to study the biomechanical behaviour of the intact mandible and customized TMJ prostheses in order to design a patient-specific total TMJ implant. The customized TMJ implant was virtually studied under simulated loading conditions using finite element method (FEM) in ANSYS Workbench and then compared to the intact jaw-mandible for the combinations of two different biocompatible material models. It is observed that the natural TMJ has a higher deformation value as compared to the patient-specific TMJ implant due to the lower mechanical strength of bone relative to the Ti-6Al-4V and Co-Cr alloy. Hence, we can conclude that the designed custom TMJ implant is safe for the patient from the point of design perspective.

20 August 2023 in Micromachines
Verified
Journal Article
Open access
PDF file
ATAnubhav Tiwari
Anubhav Tiwari
IAIshfaq Abdulrahiman Ahmed
Ishfaq Abdulrahiman Ahmed
Vijay Kumar GuptaVijay Kumar Gupta
Vijay Kumar Gupta
RHRakesh Kumar Haldkar
Rakesh Kumar Haldkar
Ivan A. ParinovIvan A. Parinov
Ivan A. Parinov
The temporomandibular joint (TMJ) is a critical joint for the opening and closing of the mouth. The generation of customised TMJs according to individuals’ dental anatomy is needed. Currently, the implants available on the market lack consideration of the patient’s dental anatomy. This leads to the creation of an imbalance in the reaction forces on both ends of the TMJ. This requires a slight structural change in the design parameters to give a solution. The purpose of this study is to propose a new design that includes the geometry and materials for a TMJ implant. Stress analysis was carried out on the TMJ to balance the reaction forces at both TMJ ends. A static analysis was performed using ANSYS Workbench, to compare the results of two customised designs of TMJ implants, in order to better balance the reaction forces at both ends. The model in the study showed that the reaction forces for both the patient-specific TMJ implants were nearly balanced. The reaction forces were better balanced, and almost equivalent to the intact conditions. The stresses in the mandible were more uniformly distributed in the customised design of the TMJ implant. The two types of design showed that the custom design took up less space in the patient’s region of surgery, making it a better option compared to a stock TMJ implant. The custom implant would allow faster patient rehabilitation, as the reaction forces would be close to those in intact conditions.