Francesca Vipiana

Prof. Francesca Vipiana

Department of Electronics and Telecommunications, Politecnico di Torino, 10129 Torino, Italy
orcid

Research Focus & Metrics

Academic Career Length

23Years (2004-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 September 2018 in IEEE Transactions on Antennas and Propagation
Verified
Journal Article
Closed access
Rosa ScapaticciRosa Scapaticci
Rosa Scapaticci
Jorge A. Tobon VasquezJorge A. Tobon Vasquez
Jorge A. Tobon Vasquez
GBGennaro Bellizzi
Gennaro Bellizzi
FVFrancesca Vipiana
Francesca Vipiana
LCLorenzo Crocco
Lorenzo Crocco
This paper presents the design of a novel lowcomplexity microwave imaging system for monitoring brain stroke. In particular, the design is concerned with the determination of the optimal layout of the antennas array, namely minimum number, positions and polarization of the radiating elements, enabling the acquisition of an amount of data such to assure a reliable imaging. This goal is achieved by adopting a rigorous design procedure based on the inspection of the singular value decomposition of the relevant discretized scattering operator and taking into account the actual dynamics and signal to noise ratio of the measurement system. The design is first carried out in the case of ideal dipoles and then extended and assessed for actual printed monopole antennas, developed for the imaging system. The resulting system is a helmet equipped with 24 antennas, whose performances have been numerically validated in terms of both spatial resolution and reconstruction capabilities, by employing full-wave numerical simulations, realistic 3-D phantoms of the human head and an accurate modeling of the actual antennas employed in the system.

3 May 2020 in Sensors
Verified
Journal Article
Open access
PDF file
Jorge A. Tobon VasquezJorge A. Tobon Vasquez
Jorge A. Tobon Vasquez
Rosa ScapaticciRosa Scapaticci
Rosa Scapaticci
GTGiovanna Turvani
Giovanna Turvani
GBGennaro Bellizzi
Gennaro Bellizzi
David Rodriguez-DuarteDavid Rodriguez-Duarte
David Rodriguez-Duarte
FVFrancesca Vipiana
Francesca Vipiana
This work focuses on brain stroke imaging via microwave technology. In particular, the open issue of monitoring patients after stroke onset is addressed here in order to provide clinicians with a tool to control the effectiveness of administered therapies during the follow-up period. In this paper, a novel prototype is presented and characterized. The device is based on a low-complexity architecture which makes use of a minimum number of properly positioned and designed antennas placed on a helmet. It exploits a differential imaging approach and provides 3D images of the stroke. Preliminary experiments involving a 3D phantom filled with brain tissue-mimicking liquid confirm the potential of the technology in imaging a spherical target mimicking a stroke of a radius equal to 1.25 cm.

12 July 2024 in Sensors
Verified
Journal Article
Open access
PDF file
COCristina Origlia
Cristina Origlia
David Rodriguez-DuarteDavid Rodriguez-Duarte
David Rodriguez-Duarte
Jorge A. Tobon VasquezJorge A. Tobon Vasquez
Jorge A. Tobon Vasquez
JBJean-Charles Bolomey
Jean-Charles Bolomey
FVFrancesca Vipiana
Francesca Vipiana
Microwaves can safely and non-destructively illuminate and penetrate dielectric materials, making them an attractive solution for various medical tasks, including detection, diagnosis, classification, and monitoring. Their inherent electromagnetic properties, portability, cost-effectiveness, and the growth in computing capabilities have encouraged the development of numerous microwave sensing and imaging systems in the medical field, with the potential to complement or even replace current gold-standard methods. This review aims to provide a comprehensive update on the latest advances in medical applications of microwaves, particularly focusing on the near-field ones working within the 1–15 GHz frequency range. It specifically examines significant strides in the development of clinical devices for brain stroke diagnosis and classification, breast cancer screening, and continuous blood glucose monitoring. The technical implementation and algorithmic aspects of prototypes and devices are discussed in detail, including the transceiver systems, radiating elements (such as antennas and sensors), and the imaging algorithms. Additionally, it provides an overview of other promising cutting-edge microwave medical applications, such as knee injuries and colon polyps detection, torso scanning and image-based monitoring of thermal therapy intervention. Finally, the review discusses the challenges of achieving clinical engagement with microwave-based technologies and explores future perspectives.

26 August 2020 in IEEE Antennas and Propagation Magazine
Verified
Journal Article
Closed access
JVJorge A. Tobon Vasquez
Jorge A. Tobon Vasquez
Rosa ScapaticciRosa Scapaticci
Rosa Scapaticci
GTGiovanna Turvani
Giovanna Turvani
MRMarco Ricci
Marco Ricci
LFLaura Farina
Laura Farina
FVFrancesca Vipiana
Francesca Vipiana

21 July 2022 in IEEE Open Journal of Antennas and Propagation
Verified
Journal Article
Open access
David Rodriguez-DuarteDavid Rodriguez-Duarte
David Rodriguez-Duarte
COCristina Origlia
Cristina Origlia
Jorge A. Tobon VasquezJorge A. Tobon Vasquez
Jorge A. Tobon Vasquez
Rosa ScapaticciRosa Scapaticci
Rosa Scapaticci
LCLorenzo Crocco
Lorenzo Crocco
FVFrancesca Vipiana
Francesca Vipiana
This paper presents the experimental validation of a microwave imaging system for real-time monitoring of brain stroke in the post-acute stage. The system exploits a low-complexity sensing apparatus and a multi-frequency microwave imaging algorithm with a novel artifact removal feature. Phantoms of a homogeneous anthropomorphic head and an ellipsoidal non-static stroke mimicking target, varying gradually from 0 cm 3 to 60 cm 3 , are employed for the experiments. The phantom and the evolving target are filled with appropriate alcohol-based mixtures to mimic the different dielectric properties of the relevant tissue. The microwave imaging scanner operates using a 22-antennas architecture formed by printed flexible antennas with a custom-made matching medium. The system provides 3-D images of the entire brain region, exploiting differential multi-view scattering measures and the distorted Born approximation to build a pre-computed imaging kernel. The results show the system’s capability to follow up the continuous progression of hemorrhage and ischemia zones with centimetric spatial resolution and to provide information on whether the stroke is growing or shrinking.

11 January 2021 in IEEE Journal of Electromagnetics, RF and Microwaves in Medicine and Biology
Verified
Journal Article
Closed access
David Rodriguez-DuarteDavid Rodriguez-Duarte
David Rodriguez-Duarte
JVJorge A. Tobon Vasquez
Jorge A. Tobon Vasquez
Rosa ScapaticciRosa Scapaticci
Rosa Scapaticci
LCLorenzo Crocco
Lorenzo Crocco
FVFrancesca Vipiana
Francesca Vipiana
This work presents the outcomes of a numerical analysis based on a 3-D high fidelity model of a realistic microwave imaging system for the clinical follow-up of brain stroke. The analysis is meant as a preliminary step towards the full experimental characterization of the system, with the aim of assessing the achievable results and highlight possible critical points. The system consists of an array of twenty-four printed monopole antennas, placed conformal to the upper part of the head; each monopole is immersed into a semi-solid dielectric brick with custom permittivity, acting as coupling medium. The whole system, including the antennas and their feeding mechanism, has been numerically modeled via a custom full-wave software based on the finite element method. The numerical model generates reliable electromagnetic operators and accurate antenna scattering parameters, which provide the input data for the implemented imaging algorithm. In particular, the numerical analysis assesses the capability of the device of reliably monitoring the evolution of hemorrhages and ischemias, considering the progression from a healthy state to an early-stage stroke.