David Rodriguez-Duarte

Prof. David Rodriguez-Duarte

Department of Electronics and Telecommunications, Politecnico di Torino, Turin, Piedmont, Italy
orcid

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 January 2019 in IEEE Transactions on Vehicular Technology
Verified
Journal Article
Closed access
MGMahdi Ben Ghorbel
Mahdi Ben Ghorbel
David Rodriguez-DuarteDavid Rodriguez-Duarte
David Rodriguez-Duarte
HGHakim Ghazzai
Hakim Ghazzai
Md. Jahangir HossainMd. Jahangir Hossain
Md. Jahangir Hossain
HMHamid Menouar
Hamid Menouar
Unnamed aerial vehicles (UAVs) or drones have attracted growing interest in the last few years for multiple applications; thanks to their advantages in terms of mobility, easy movement, and flexible positioning. In UAV-based communications, mobility and higher line-of-sight probability represent opportunities for the flying UAVs while the limited battery capacity remains its major challenge. Thus, they can be employed for specific applications where their permanent presence is not mandatory. Data gathering from wireless sensor networks is one of these applications. This paper proposes an energy-efficient solution minimizing the UAV and/or sensors energy consumption while accomplishing a tour to collect data from the spatially distributed wireless sensors. The objective is to determine the positions of the UAV “stops” from which it can collect data from a subset of sensors located in the same neighborhood and find the path that the UAV should follow to complete its data gathering tour in an energy-efficient manner. A non-convex optimization problem is first formulated then, an efficient and low-complex technique is proposed to iteratively achieve a sub-optimal solution. The initial problem is decomposed into three sub-problems: The first sub-problem optimizes the positioning of the stops using linearization. The second one determines the sensors assignment to stops using clustering. Finally, the path among these stops is optimized using the travel salesman problem. Selected numerical results show the behavior of the UAV versus various system parameters and that the achieved energy is considerably reduced compared to the one of existing approaches.

3 May 2020 in Sensors
Verified
Journal Article
Open access
PDF file
Jorge A. Tobon VasquezJorge A. Tobon Vasquez
Jorge A. Tobon Vasquez
Rosa ScapaticciRosa Scapaticci
Rosa Scapaticci
GTGiovanna Turvani
Giovanna Turvani
GBGennaro Bellizzi
Gennaro Bellizzi
David Rodriguez-DuarteDavid Rodriguez-Duarte
David Rodriguez-Duarte
FVFrancesca Vipiana
Francesca Vipiana
This work focuses on brain stroke imaging via microwave technology. In particular, the open issue of monitoring patients after stroke onset is addressed here in order to provide clinicians with a tool to control the effectiveness of administered therapies during the follow-up period. In this paper, a novel prototype is presented and characterized. The device is based on a low-complexity architecture which makes use of a minimum number of properly positioned and designed antennas placed on a helmet. It exploits a differential imaging approach and provides 3D images of the stroke. Preliminary experiments involving a 3D phantom filled with brain tissue-mimicking liquid confirm the potential of the technology in imaging a spherical target mimicking a stroke of a radius equal to 1.25 cm.

12 July 2024 in Sensors
Verified
Journal Article
Open access
PDF file
COCristina Origlia
Cristina Origlia
David Rodriguez-DuarteDavid Rodriguez-Duarte
David Rodriguez-Duarte
Jorge A. Tobon VasquezJorge A. Tobon Vasquez
Jorge A. Tobon Vasquez
JBJean-Charles Bolomey
Jean-Charles Bolomey
FVFrancesca Vipiana
Francesca Vipiana
Microwaves can safely and non-destructively illuminate and penetrate dielectric materials, making them an attractive solution for various medical tasks, including detection, diagnosis, classification, and monitoring. Their inherent electromagnetic properties, portability, cost-effectiveness, and the growth in computing capabilities have encouraged the development of numerous microwave sensing and imaging systems in the medical field, with the potential to complement or even replace current gold-standard methods. This review aims to provide a comprehensive update on the latest advances in medical applications of microwaves, particularly focusing on the near-field ones working within the 1–15 GHz frequency range. It specifically examines significant strides in the development of clinical devices for brain stroke diagnosis and classification, breast cancer screening, and continuous blood glucose monitoring. The technical implementation and algorithmic aspects of prototypes and devices are discussed in detail, including the transceiver systems, radiating elements (such as antennas and sensors), and the imaging algorithms. Additionally, it provides an overview of other promising cutting-edge microwave medical applications, such as knee injuries and colon polyps detection, torso scanning and image-based monitoring of thermal therapy intervention. Finally, the review discusses the challenges of achieving clinical engagement with microwave-based technologies and explores future perspectives.

21 July 2022 in IEEE Open Journal of Antennas and Propagation
Verified
Journal Article
Open access
David Rodriguez-DuarteDavid Rodriguez-Duarte
David Rodriguez-Duarte
COCristina Origlia
Cristina Origlia
Jorge A. Tobon VasquezJorge A. Tobon Vasquez
Jorge A. Tobon Vasquez
Rosa ScapaticciRosa Scapaticci
Rosa Scapaticci
LCLorenzo Crocco
Lorenzo Crocco
FVFrancesca Vipiana
Francesca Vipiana
This paper presents the experimental validation of a microwave imaging system for real-time monitoring of brain stroke in the post-acute stage. The system exploits a low-complexity sensing apparatus and a multi-frequency microwave imaging algorithm with a novel artifact removal feature. Phantoms of a homogeneous anthropomorphic head and an ellipsoidal non-static stroke mimicking target, varying gradually from 0 cm 3 to 60 cm 3 , are employed for the experiments. The phantom and the evolving target are filled with appropriate alcohol-based mixtures to mimic the different dielectric properties of the relevant tissue. The microwave imaging scanner operates using a 22-antennas architecture formed by printed flexible antennas with a custom-made matching medium. The system provides 3-D images of the entire brain region, exploiting differential multi-view scattering measures and the distorted Born approximation to build a pre-computed imaging kernel. The results show the system’s capability to follow up the continuous progression of hemorrhage and ischemia zones with centimetric spatial resolution and to provide information on whether the stroke is growing or shrinking.

11 January 2021 in IEEE Journal of Electromagnetics, RF and Microwaves in Medicine and Biology
Verified
Journal Article
Closed access
David Rodriguez-DuarteDavid Rodriguez-Duarte
David Rodriguez-Duarte
JVJorge A. Tobon Vasquez
Jorge A. Tobon Vasquez
Rosa ScapaticciRosa Scapaticci
Rosa Scapaticci
LCLorenzo Crocco
Lorenzo Crocco
FVFrancesca Vipiana
Francesca Vipiana
This work presents the outcomes of a numerical analysis based on a 3-D high fidelity model of a realistic microwave imaging system for the clinical follow-up of brain stroke. The analysis is meant as a preliminary step towards the full experimental characterization of the system, with the aim of assessing the achievable results and highlight possible critical points. The system consists of an array of twenty-four printed monopole antennas, placed conformal to the upper part of the head; each monopole is immersed into a semi-solid dielectric brick with custom permittivity, acting as coupling medium. The whole system, including the antennas and their feeding mechanism, has been numerically modeled via a custom full-wave software based on the finite element method. The numerical model generates reliable electromagnetic operators and accurate antenna scattering parameters, which provide the input data for the implemented imaging algorithm. In particular, the numerical analysis assesses the capability of the device of reliably monitoring the evolution of hemorrhages and ischemias, considering the progression from a healthy state to an early-stage stroke.

7 September 2020 in IEEE Antennas and Wireless Propagation Letters
Verified
Journal Article
Closed access
David Rodriguez-DuarteDavid Rodriguez-Duarte
David Rodriguez-Duarte
Jorge A. Tobon VasquezJorge A. Tobon Vasquez
Jorge A. Tobon Vasquez
Rosa ScapaticciRosa Scapaticci
Rosa Scapaticci
LCLorenzo Crocco
Lorenzo Crocco
FVFrancesca Vipiana
Francesca Vipiana
In this letter, we describe and validate a microwave antenna designed for an imaging device for the diagnosis and monitoring of cerebrovascular pathologies. The antenna consists of a printed monopole immersed in a parallelepipedic block of semi-flexible material with custom-permittivity, which allows to avoid the use of liquid coupling media and enables a simple array arrangement. The "brick" is built with a mixture of urethane rubber and graphite powder. The -10 dB frequency band of the antenna is 800 MHz 1.2 GHz, in agreement with the device requirements. The designed brick antenna is assessed in terms of power penetration, reflection and transmission coefficients. To show the performance of the antenna in the relevant application scenario, an experiment has been carried out on an anthropomorphic head phantom, measuring the differential signals between healthy state and hemorrhagic stroke mimicking condition for different antennas positions.