Pietro Morozzi

Dr. Pietro Morozzi

orcid

Research Focus & Metrics

Representative Publications

View All Publications
29 May 2020 in Sensors
Verified
Journal Article
Open access
PDF file
Erika BrattichErika Brattich
Erika Brattich
ABAlessandro Bracci
Alessandro Bracci
AZAlessandro Zappi
Alessandro Zappi
PMPietro Morozzi
Pietro Morozzi
SSSILVANA DI SABATINO
SILVANA DI SABATINO
Laura TosittiLaura Tositti
Laura Tositti
Low-cost sensors based on the optical particle counter (OPC) are increasingly being used to collect particulate matter (PM) data at high space and time resolution. In spite of their huge explorative potential, practical guidelines and recommendations for their use are still limited. In this work, we outline a few best practices for the optimal use of PM low-cost sensors based on the results of an intensive field campaign performed in Bologna (44°30′ N, 11°21′ E; Italy) under different weather conditions. Briefly, the performances of a series of sensors were evaluated against a calibrated mainstream OPC with a heated inlet, using a robust approach based on a suite of statistical indexes capable of evaluating both correlations and biases in respect to the reference sensor. Our results show that the sensor performance is sensibly affected by both time resolution and weather with biases maximized at high time resolution and high relative humidity. Optimization of PM data obtained is therefore achievable by lowering time resolution and applying suitable correction factors for hygroscopic growth based on the inherent particle size distribution.

17 July 2019 in Molecules
Verified
Journal Article
Open access
PDF file
PMPietro Morozzi
Pietro Morozzi
AZAlessandro Zappi
Alessandro Zappi
FGFernando Gottardi
Fernando Gottardi
Marcello LocatelliMarcello Locatelli
Marcello Locatelli
Dora MelucciDora Melucci
Dora Melucci
Saffron is one of the most adulterated food products all over the world because of its high market prize. Therefore, a non-targeted approach based on the combination of headspace flash gas-chromatography with flame ionization detection (HS-GC-FID) and chemometrics was tested and evaluated to check adulteration of this spice with two of the principal plant-derived adulterants: turmeric (Curcuma longa L.) and marigold (Calendula officinalis L.). Chemometric models were carried out through both linear discriminant analysis (LDA) and partial least squares discriminant analysis (PLS-DA) from the gas-chromatographic data. These models were also validated by cross validation (CV) and external validation, which were performed by testing both models on pure spices and artificial mixtures capable of simulating adulterations of saffron with the two adulterants examined. These models gave back satisfactory results. Indeed, both models showed functional internal and external prediction ability. The achieved results point out that the method based on a combination of chemometrics with gas-chromatography may provide a rapid and low-cost screening method for the authentication of saffron.

31 October 2019 in Molecules
Verified
Journal Article
Open access
PDF file
Dora MelucciDora Melucci
Dora Melucci
AZAlessandro Zappi
Alessandro Zappi
FPFrancesca Poggioli
Francesca Poggioli
PMPietro Morozzi
Pietro Morozzi
Federico GiglioFederico Giglio
Federico Giglio
Laura TosittiLaura Tositti
Laura Tositti
Biogenic silica is the major component of the external skeleton of marine micro-organisms, such as diatoms, which, after the organisms death, settle down onto the seabed. These micro-organisms are involved in the CO2 cycle because they remove it from the atmosphere through photosynthesis. The biogenic silica content in marine sediments, therefore, is an indicator of primary productivity in present and past epochs, which is useful to study the CO2 trends. Quantification of biosilica in sediments is traditionally carried out by wet chemistry followed by spectrophotometry, a time-consuming analytical method that, besides being destructive, is affected by a strong risk of analytical biases owing to the dissolution of other silicatic components in the mineral matrix. In the present work, the biosilica content was directly evaluated in sediment samples, without chemically altering them, by attenuated total reflection Fourier transform infrared (ATR-FTIR) spectroscopy. Quantification was performed by combining the multivariate standard addition method (MSAM) with the net analyte signal (NAS) procedure to solve the strong matrix effect of sediment samples. Twenty-one sediment samples from a sediment core and one reference standard sample were analyzed, and the results (extrapolated concentrations) were found to be comparable to those obtained by the traditional wet method, thus demonstrating the feasibility of the ATR-FTIR-MSAM-NAS approach as an alternative method for the quantification of biosilica. Future developments will cover in depth investigation on biosilica from other biogenic sources, the extension of the method to sediments of other provenance, and the use higher resolution IR spectrometers.

1 November 2020 in Science of The Total Environment
Verified
Journal Article
Closed access
Laura TosittiLaura Tositti
Laura Tositti
BMBeatrice Moroni
Beatrice Moroni
EDEnrico Dinelli
Enrico Dinelli
PMPietro Morozzi
Pietro Morozzi
Erika BrattichErika Brattich
Erika Brattich
DCDavid Cappelletti
David Cappelletti

1 December 2022 in Ecohydrology
Verified
Journal Article
Closed access
Rosangela AddessoRosangela Addesso
Rosangela Addesso
PMPietro Morozzi
Pietro Morozzi
Laura TosittiLaura Tositti
Laura Tositti
JWJo De Waele
Jo De Waele
DBDaniela Baldantoni
Daniela Baldantoni

8 May 2024 in Analytica
Verified
Journal Article
Open access
PDF file
AZAlessandro Zappi
Alessandro Zappi
Alessandra BiancolilloAlessandra Biancolillo
Alessandra Biancolillo
NKNicholas Kassouf
Nicholas Kassouf
VMValentina Marassi
Valentina Marassi
PMPietro Morozzi
Pietro Morozzi
Dora MelucciDora Melucci
Dora Melucci
A novel approach for the quantification of recycled polyethylene terephthalate (r-PET) in commercial bottles is presented. Fifty-eight bottle samples from several brands and producers containing different percentages of r-PET were purchased from the market. Samples were analyzed by two spectroscopic methods: near-infrared (NIR) spectroscopy and attenuated total reflection (ATR) spectroscopy in the mid-infrared (MIR) region. No chemical pre-treatment was applied before analyses. The spectra were analyzed by partial-least squares (PLS) regression, and two models for NIR and MIR data were computed. Then, a multi-block regression was applied to join the two datasets. All models were validated by cross-validation and by excluding and projecting onto the model the replicated spectra of one sample at a time. Results demonstrated the potential of this approach, especially considering the variability of commercial samples in terms of additives, shape, or thickness of the bottles: for samples close to the centroids of the models (i.e., from 10 to 50% r-PET), the predictions of multi-block method seldom departed from the expected values of ±10%. Only for samples with 0% declared r-PET, the models showed poor prediction abilities.