Magdalena Fronczek

Dr. Magdalena Fronczek

orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 April 2022 in Materials
Verified
Journal Article
Open access
PDF file
ASAgata Szczesio-Wlodarczyk
Agata Szczesio-Wlodarczyk
APAleksander Polikowski
Aleksander Polikowski
MKMichał Krasowski
Michał Krasowski
MFMagdalena Fronczek
Magdalena Fronczek
JSJerzy Sokołowski
Jerzy Sokołowski
KBKinga Bociong
Kinga Bociong
Bisphenol A-glycidyl methacrylate (bis-GMA) and urethane dimethacrylate (UDMA) are usually combined with low-viscosity monomers to obtain more desirable viscosity, handling characteristics and general properties. The present study determined the flexural strength (FS), flexural modulus (FM), diametral tensile strength (DTS), and hardness (HV) of five matrices and composites based on these resins. The polymerization shrinkage stress (PSS) was also studied for the composites. The polymer matrices were formed using bis-GMA and UDMA. TEGDMA, HEMA and HDDMA acted as co-monomers. The composites had 45 wt.% of filler content. The highest FS and FM were obtained from the UDMA/bis-GMA/TEGDMA/HEMA matrix and the composite (matrix + filler). The best DTS values were obtained from the UDMA/bis-GMA/HEMA matrix and the composite. One of the lowest values of FS, FM, and DTS was obtained from the UDMA/bis-GMA/HDDMA matrix and the composite. All the composites demonstrated similar hardness values. The lowest polymerization shrinkage stress was observed for the UDMA/bis-GMA/TEGDMA/HEMA composite, and the highest PSS was observed for the UDMA/bis-GMA/TEGDMA/HDDMA composite. The addition of HEMA had a positive effect on the properties of the tested materials, which may be related to the improved mobility of the bis-GMA and UDMA monomers.

30 May 2022 in Molecules
Verified
Journal Article
Open access
PDF file
ASAgata Szczesio-Wlodarczyk
Agata Szczesio-Wlodarczyk
MFMagdalena Fronczek
Magdalena Fronczek
KRKatarzyna Ranoszek-Soliwoda
Katarzyna Ranoszek-Soliwoda
JGJarosław Grobelny
Jarosław Grobelny
JSJerzy Sokołowski
Jerzy Sokołowski
KBKinga Bociong
Kinga Bociong
The clinical performance of a dental restoration is strongly influenced by the complex and dynamically-changing oral environment; however, no standard procedure exists to evaluate this lifetime. This research provides an in-depth analysis of the effect of different aging procedures on the flexural strength (FS), diametral tensile strength (DTS) and hardness (HV) of selected dental materials (Resin F, Flow-Art and Arkon). Material structure was evaluated by scanning electron microscopy. It was found that each aging protocol had some influence on the tested properties, with continual erosion and degradation being observed. Greater mechanical degradation was observed for Resin F (neat resin) after the applied aging protocols, suggesting that a resin matrix is more susceptible for degradation. The most aggressive aging protocol was Protocol 5: 0.1 M NaOH, seven days, 60 °C. Further studies on the effect of artificial aging on dental materials should include a study of the thermal and chemical factors. A standardized aging procedure is crucial for improving the resistance of dental resin composite to oral conditions and their clinical performance.

15 October 2021 in Coatings
Verified
Journal Article
Open access
PDF file
MDMonika Domarecka
Monika Domarecka
ASAgata Szczesio-Wlodarczyk
Agata Szczesio-Wlodarczyk
MKMichał Krasowski
Michał Krasowski
MFMagdalena Fronczek
Magdalena Fronczek
TGTomasz Gozdek
Tomasz Gozdek
KBKinga Bociong
Kinga Bociong
Dual-curing composites have a wide spectrum of use in practice (rebuilding, reconstruction, and luting). The characterization of this type of material and comparative study of selected mechanical properties with light-cured materials were carried out for this paper. In this study, we used six materials with a dual-cure system—Bulk EZ, Fill-Up!, StarFill 2B, Rebilda DC, MultiCore Flow, Activa Bioactive-Restorative—and three light-cured materials—Filtek Bulk Fill Posterior, Charisma Classic, and G-aenial Universal Flo. The materials were conditioned for 24 h in water at 37 °C before testing. Selected material properties were determined: three-point bending flexural strength, diametral tensile strength, hardness, microhardness, and shrinkage stress. The highest three-point bending flexural strength (TPB) was 137.0 MPa (G-aenial Universal Flo), while the lowest amounted to 86.5 MPa (Activa Bioactive). The diametral tensile strength (DTS) values were in a range from 39.2 MPa (Rebilda DC) to 54.1 MPa (Charisma Classic). The lowest hardness (HV) value of 26 was obtained by the Activa Bioactive material, while the highest values were recorded for Filtek Bulk Fill Posterior and Charisma Classic-53. The shrinkage stress of the tested materials ranged from 6.3 MPa (Charisma Classic) to 13.2 MPa (G-aenial Universal Flo). Dual-curing composites were found to have similar properties to light-cured composites.

2 October 2018 in Polymers
Verified
Journal Article
Open access
PDF file
KSKrzysztof Sokolowski
Krzysztof Sokolowski
ASAgata Szczesio-Wlodarczyk
Agata Szczesio-Wlodarczyk
KBKinga Bociong
Kinga Bociong
MKMichał Krasowski
Michał Krasowski
MFMagdalena Fronczek
Magdalena Fronczek
Monika Lukomska-SzymanskaMonika Lukomska-Szymanska
Monika Lukomska-Szymanska
Ion-releasing polymeric restorative materials seem to be promising solutions, due to their possible anticaries effect. However, acid functional groups (monomers) and glass filler increase hydrophilicity and, supposedly, water sorption. The purpose of the study was to evaluate the influence of water sorption of polymeric materials on the stress state at the restoration-tooth interface. Beautifil Bulk Fill Flow, Beautifil Flow Plus F00, Beautifil Flow F02, Dyract eXtra, Compoglass Flow, Ionosit, Glasiosite, TwinkiStar, Ionolux and Fuji II LC were used for the study. The stress state was measured using photoelastic analysis after: 0.5, 24, 72, 96, 168, 240, 336, 504, 672, 1344 and 2016 h. Moreover, water sorption, solubility and absorption dynamic were assessed. The water sorption, solubility and absorption dynamic of ion-releasing restorative materials are material dependent properties. The overall results indicated that the tested restorative materials showed significant stress decrease. The total reduction in contraction stress and water expansion stress was not observed for materials with low value of water sorption (Beautifil Bulk Fill, Dyract eXtra, Glasionosit and Twinky Star). The photoelastic method turned out to be inadequate to evaluate stress changes of resin modified glass-ionomer cement (RMGI, Fuji II LC and Ionolux).

1 December 2016 in International Journal of Performance Analysis in Sport
Verified
Journal Article
Open access
MFMagdalena Fronczek
Magdalena Fronczek
GPGianluca Padula
Gianluca Padula
JKJoanna Kowalska
Joanna Kowalska
MGManuela Galli
Manuela Galli
SLSalvatore Livatino
Salvatore Livatino
KKKarolina Kopacz
Karolina Kopacz
The aim of this study was to assess static and dynamic balance related to rotational movements en pointe and en demi pointe in ballet dance students. The study group consisted of 13 people – students of one of the ballet schools in Poland: 9 dancers from the junior class (14 years old) and 4 dancers form the senior class (18 years old). For the purpose of statistical analysis, the group was divided into 4 subgroups. Each person took part in a static balance test which included a 30s trial with eyes opened and 30s trial with eyes closed. The examination of dynamic balance related to rotational movements was also performed to compare movements en pointe vs. movements en demi pointe. Analyses were performed using the Kistler 9286BA platforms, which are the module of BTS Smart DX 7000. Data processing was performed with the use of BTS Sway and Statistica 10. Accepted level of significance was α = 0.05. Increase in the following center of pressure parameters was observed in the examination with eyes closed: maximal radius, longitudinal range, equivalent area and velocity. Participants from the senior class did not show these differences. There were no differences found between movements en demi pointe in comparison with movements en pointe. Static balance deteriorated with eyes closed in the entire examined group. Participants from the senior class showed more stable parameters of static balance. There were no differences in dynamic balance when the base of support was decreased.

8 August 2024 in Applied Sciences
Verified
Journal Article
Open access
PDF file
ASAgata Szczesio-Wlodarczyk
Agata Szczesio-Wlodarczyk
MFMagdalena Fronczek
Magdalena Fronczek
KRKatarzyna Ranoszek-Soliwoda
Katarzyna Ranoszek-Soliwoda
JSJerzy Sokołowski
Jerzy Sokołowski
KBKinga Bociong
Kinga Bociong
The durability and performance of dental composites are essential for ensuring long-lasting dental restorations. However, there is a lack of a standardized procedure for evaluating the lifespan of dental materials. Our proposal assumed that dental materials should be tested under aggressive aging conditions to accelerate materials’ degradation in vitro and such an approach should simulate prolonged material usage in the oral cavity. A comprehensive examination of the impacts of three aging methodologies on various mechanical properties, including the flexural strength (FS), diametral tensile strength (DTS), hardness (HV), fracture toughness (FT), flexural fatigue limit (FFL), and microstructure of selected dental materials (Resin F, Flow-Art and Arkon), was conducted. The findings revealed that preformed aging results in an average reduction of 30% in the mechanical strength properties of the dental composites when compared to the control. Notably, a strong correlation was identified between FS and FFL post-aging whereas no such relationship was observed between these parameters and FT. This paper highlights the significance of aging tests for new dental composites and recommends a focus on flexural strength and fracture toughness to optimize costs and time efficiency. Furthermore, the establishment of a standardized test for fracture toughness in dental composites is recommended. It is proposed that a minimum flexural strength of more than 32–48 MPa after aging should be maintained. A more extensive analysis of commercially available materials is suggested to refine the proper evaluation methods for composite materials.