Elutunji Buraimoh

Dr. Elutunji Buraimoh

Durban University of Technology
orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 June 2022 in Energies
Verified
Journal Article
Open access
PDF file
Elutunji BuraimohElutunji Buraimoh
Elutunji Buraimoh
AAAnuoluwapo Oluwatobiloba Aluko
Anuoluwapo Oluwatobiloba Aluko
OOOluwafemi Emmanuel Oni
Oluwafemi Emmanuel Oni
Innocent Ewean DavidsonInnocent Ewean Davidson
Innocent Ewean Davidson
The work presents the power-sharing in a standalone low voltage AC microgrid consisting of three parallel grid supporting inverters using a virtual impedance-based droop system. Typically, isolated microgrids suffer unique challenges regarding voltage, current, frequency regulation, power flow control, and power-sharing due to the absence of a stiff AC grid source. This work investigated the power flow and sharing technical challenges using three inverter-based distributed energy sources, three static loads, and one dynamic load. These distributed energy sources are interconnected with the loads using low voltage line impedance within the microgrid to implement the uneven power distribution. Furthermore, a distributed grid supporting control utilizing virtual impedance is proposed in this work to improve power-sharing. The microgrid model is developed with the MATLAB Simulink environment and validated using the Opal RT OP4510 simulator. The proposed technique ensured improved power-sharing and mitigated the effect of voltage drops introduced through a virtual impedance using combined positive and negative virtual.

26 December 2022 in Cogent Engineering
Verified
Journal Article
Open access
OBOlubayo Babatunde
Olubayo Babatunde
Elutunji BuraimohElutunji Buraimoh
Elutunji Buraimoh
OTOluwatobi Tinuoye
Oluwatobi Tinuoye
CAClement Ayegbusi
Clement Ayegbusi
IDInnocent Davidson
Innocent Davidson
DIDesmond Eseoghene Ighravwe
Desmond Eseoghene Ighravwe
To improve the electricity services in Nigeria, the government has embarked on a total reform of the Nigerian Electricity Supply Industry. The reform started with rehabilitating the government-owned electricity infrastructures in 1999 and implementing the 2010 Power Sector Reform. While some stakeholders have seen these reforms benefit the industry, others have yet to see the positive impact of the reforms. Based on this premise, this work presents a synopsis of the Nigerian power sector’s past, present, and future. A review of its state of the art is explored and presented using documents and recent literature on the Nigerian electricity sector. Findings from the study show that infrastructural deficits and administrative lapses dominated the pre-liberation era. The privatization of electricity led to organizational structure and infrastructure improvements. The sector was unbundled into the GenCos, TransCo, Discos, and the regulatory bodies assigned well-defined tasks. The generation capacity has increased to 16,384 MW against the pre-liberation figure of approximately 6000 MW. As against the approximate figure of 10,000 km covered by the transmission infrastructure, an additional 10,000 km has been added to the existing transmission facilities. Although there have been improvements in service deliveries, there are still more grounds to cover to stabilize the Nigerian electricity sector. It is proposed that stakeholders harmonize the various policies and structural changes to make the necessary improvements.

19 September 2023 in IEEE Access
Verified
Journal Article
Open access
Elutunji BuraimohElutunji Buraimoh
Elutunji Buraimoh
GOGokhan Ozkan
Gokhan Ozkan
LTLaxman Timilsina
Laxman Timilsina
PCPhani Kumar Chamarthi
Phani Kumar Chamarthi
BPBehnaz Papari
Behnaz Papari
CEChris S. Edrington
Chris S. Edrington
In recent years, there has been growing research interest in the virtual integration of hardware and software assets across different geographical locations. However, achieving joint real-time simulation in virtually connected laboratories presents several challenges that must be addressed. One critical aspect involves selecting suitable interface algorithms to conserve energy, ensure signal decomposition, and reconstruct data accurately, thereby preventing distortions. Additionally, communication latencies must be taken into account to maintain experiment fidelity. The establishment of fast and reliable communication between real-time simulators in different laboratories through coupling interfaces, is of utmost importance for successful real-time co-simulation. Nevertheless, assuming the constant availability of reliable and delay-free communication is unrealistic, which can lead to performance degradation and system instability. These requirements pose significant obstacles to implementing virtual integration involving various real-time simulators and hardware-in-the-loop setups across diverse laboratories. The real-time co-simulation of power systems, in particular, is highly susceptible to ineffective interface algorithms, signal decomposition, and reconstruction, as well as communication delays, potentially causing loss of synchronism and negatively impacting simulation fidelity. Consequently, these limitations render such setups unsuitable for dynamic and transient studies. In light of these challenges, this paper aims to provide an overview of interface algorithms, signal decomposition and reconstruction techniques, communication protocols, and delay compensation approaches. The goal is to ensure system fidelity, enhance coupling point modeling, and improve the accuracy of real-time co-simulation in virtual environments across long distances while preserving ongoing research confidentiality, safeguarding intellectual property, and facilitating collaborative research.

1 June 2018
Verified
Conference Paper
Closed access
Sindisiwe MalandaSindisiwe Malanda
Sindisiwe Malanda
Innocent Ewean DavidsonInnocent Ewean Davidson
Innocent Ewean Davidson
ESEddie Singh
Eddie Singh
Elutunji BuraimohElutunji Buraimoh
Elutunji Buraimoh
The purpose of designing suitable grounding system is to ensure reliable power supply, safety of equipment and people working in electrical power operation and to limit voltage elevation to a minimum. In this paper, a series of tests were conducted to compare apparent soil resistivity of two different locations and how it is affected by depth of the soil and moisture content. The Wenner method was used to measure resistivity in both locations. The results obtained show how the soil resistivity varies with depth and spacing, which informs the design of earthing protection schemes for worst case scenarios. It was observed that the soil resistivity varies based on the type of soil and moisture content. The wet soil had lower resistivity than the dry soil. The proposed design shows that the number of earth electrodes required varies from 4 to 11 for wet to dry soil conditions respectively in Site-1, and 18 to 35 earth electrodes for wet to dry soil conditions respectively in Site-2. Thus, the number of electrodes required is higher for dry soil condition, because the soil resistivity is high.

28 May 2022 in Energies
Verified
Journal Article
Open access
PDF file
AAAnuoluwapo Oluwatobiloba Aluko
Anuoluwapo Oluwatobiloba Aluko
Elutunji BuraimohElutunji Buraimoh
Elutunji Buraimoh
OOOluwafemi Emmanuel Oni
Oluwafemi Emmanuel Oni
Innocent Ewean DavidsonInnocent Ewean Davidson
Innocent Ewean Davidson
In an islanded DC microgrid with multiple distributed generators (DGs), the droop control is employed to realize proportional current sharing among the DGs in the microgrid. The action of the droop control causes a deviation in the DC bus voltage which is exacerbated by the line impedance between the DG and the DC bus. In this paper, an advanced distributed secondary control scheme is proposed to simultaneously achieve accurate voltage regulation and cooperative current sharing in the islanded DC microgrid system. The proposed distributed secondary controller is introduced in the cyber layer of the system, and each controller shares information with neighbouring controllers via a communication network. The distributed technique maintains the reliability of the overall system if some part of the communication link fails. The proposed controller uses the type-II fuzzy logic scheme to adaptively select the secondary control parameters for an improved response of the controller. The sufficient conditions to guarantee the stability of the proposed controller are derived using the Lyapunov method. Comprehensive tests under different operating scenarios are conducted to demonstrate the robustness of the proposed control scheme.

1 August 2019
Verified
Conference Paper
Closed access
OAOLADIMEJI JOSEPH AYAMOLOWO
OLADIMEJI JOSEPH AYAMOLOWO
Elutunji BuraimohElutunji Buraimoh
Elutunji Buraimoh
Ayodeji Olalekan SalauAyodeji Olalekan Salau
Ayodeji Olalekan Salau
JDJoseph O. Dada
Joseph O. Dada
Electric power system in Nigeria has undergone a lot of transformation both in its physical structure and organization. From a small generating station, it has metamorphosed into its present form of 16 generating stations, a transmission company and 11 distributed companies. Considering its present state and the need to harness the abundant renewable energy resources in the country, it is envisioned that the transformation will continue into the future. The aim of this paper is to X-ray the evolution of the electric power supply system in Nigeria, and to project into the future the necessary changes needed to meet the ever increasing load demand of Nigerians. The survey revealed that with the right policies in place private sector participation will be encouraged, leading to the rapid development of the Power Sector.