Vahid Farmehini

Mr. Vahid Farmehini


Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 September 2019 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Closed access
VFVahid Farmehini
Vahid Farmehini
WVWalter Varhue
Walter Varhue
ASArmita Salahi
Armita Salahi
AHAlexandra R Hyler
Alexandra R Hyler
JCJaka Cemazar
Jaka Cemazar
NSNathan Swami
Nathan Swami
Objective: Assessing the effectiveness of microfluidic device structures for enabling electrokinetic or acoustic trapping requires imaging of model particles within each device under the requisite force fields. To avoid the need for extensive microscopy, the use of valuable biological samples, and reliance on a trained operator to assess efficacy of trapping, we explore electrical means to identify device geometry variations that are responsible for the poor trapping. Results: Using the example of AC electrokinetic trapping over an insulated channel in a contact-less dielectrophoresis mode, we present an on-chip method to acquire impedance spectra on the microfluidic device for quantifying the parasitic voltage drops. Conclusion: Based on the parasitic voltage drops, device geometries can be designed to maximize fraction of the applied voltage that is available for dielectrophoretic manipulation and the measured on-chip impedance can rapidly inform downstream decisions on particle manipulation.

21 July 2019 in Micromachines
Verified
Journal Article
Open access
PDF file
CCCharles Clark
Charles Clark
VFVahid Farmehini
Vahid Farmehini
LSLiam Spiers
Liam Spiers
MWM. Shane Woolf
M. Shane Woolf
NSNathan Swami
Nathan Swami
James P. LandersJames P. Landers
James P. Landers
Acoustic differential extraction has been previously reported as a viable alternative to the repetitive manual pipetting and centrifugation steps for isolating sperm cells from female epithelial cells in sexual assault sample evidence. However, the efficiency of sperm cell isolation can be compromised in samples containing an extremely large number of epithelial cells. When highly concentrated samples are lysed, changes to the physicochemical nature of the medium surrounding the cells impacts the acoustic frequency needed for optimal trapping. Previous work has demonstrated successful, automated adjustment of acoustic frequency to account for changes in temperature and buffer properties in various samples. Here we show that, during acoustic trapping, real-time monitoring of voltage measurements across the piezoelectric transducer correlates with sample-dependent changes in the medium. This is achieved with a wideband peak detector circuit, which identifies the resonant frequency with minimal disruption to the applied voltage. We further demonstrate that immediate, corresponding adjustments to acoustic trapping frequency provides retention of sperm cells from high epithelial cell-containing mock sexual assault samples.