M. Shane Woolf

Dr. M. Shane Woolf

orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 December 2020 in Nature Protocols
Verified
Journal Article
Closed access
PDF file
MWM. Shane Woolf
M. Shane Woolf
LDLeah M. Dignan
Leah M. Dignan
ASAnchi T. Scott
Anchi T. Scott
James P. LandersJames P. Landers
James P. Landers

1 April 2019 in Sensors and Actuators B: Chemical
Verified
Journal Article
Closed access
SKShannon T. Krauss
Shannon T. Krauss
MWM. Shane Woolf
M. Shane Woolf
KHKevyn C. Hadley
Kevyn C. Hadley
NCNatalie M. Collins
Natalie M. Collins
ANAeren Q. Nauman
Aeren Q. Nauman
JLJames P. Landers
James P. Landers

6 March 2020 in Lab on a Chip
Verified
Journal Article
Closed access
PDF file
MWM. Shane Woolf
M. Shane Woolf
LDLeah M. Dignan
Leah M. Dignan
HLHannah M. Lewis
Hannah M. Lewis
CTChristopher J. Tomley
Christopher J. Tomley
ANAeren Q. Nauman
Aeren Q. Nauman
JLJames P. Landers
James P. Landers
Microvalving is a pivotal component in many microfluidic lab-on-a-chip platforms and micro-total analysis systems (μTAS). Effective valving is essential for the integration of multiple unit operations, such as, liquid transport, mixing, aliquoting, metering, washing, and fractionation. The ideal microfluidic system integrates numerous, sequential unit operations, provides precise spaciotemporal reagent release and flow control, and is amenable to rapid, low-cost fabrication and prototyping. Centrifugal microfluidics is an attractive approach that minimizes the need for supporting peripheral hardware. However, many of the microfluidic valving methods described in the literature suffer from operational limitations and fail when high rotational frequencies or pressure heads are required early in the analytical process. Current approaches to valve closure add unnecessary complexity to the microfluidic architecture, require the incorporation of additional materials such as wax, and entail extra fabrication steps or processes. Herein we report the characterization and optimization of a laser-actuated, closable valve method for polymeric microfluidic devices that ameliorates these shortcomings. Under typical operational conditions (rcf ≤605 × g) a success rate >99% was observed, i.e. successful valve closures remained leak free through 605 × g. Implementation of the laser-actuated closable valving system is demonstrated on an automated, centrifugally driven dynamic solid phase extraction (dSPE) device. Compatibility of this laser-actuated valve closure approach with commercially available polymerase chain reaction (PCR) assays is established by the generation of full 18-plex STR profiles from DNA purified via on-disc dSPE. This novel approach promises to simplify microscale valving, improve functionality by increasing the number of integrated unit operations, and allow for the automation of progressively complex biochemical assays.


27 June 2020 in Micromachines
Verified
Journal Article
Open access
PDF file
CCCharles Clark
Charles Clark
MWM. Shane Woolf
M. Shane Woolf
SKSarah L. Karstens
Sarah L. Karstens
HLHannah M. Lewis
Hannah M. Lewis
ANAeren Q. Nauman
Aeren Q. Nauman
James P. LandersJames P. Landers
James P. Landers
This study explores three unique approaches for closing valves and channels within microfluidic systems, specifically multilayer, centrifugally driven polymeric devices. Precise control over the cessation of liquid movement is achieved through either the introduction of expanding polyurethane foam, the application of direct contact heating, or the redeposition of xerographic toner via chloroform solvation and evaporation. Each of these techniques modifies the substrate of the microdevice in a different way. All three are effective at closing a previously open fluidic pathway after a desired unit operation has taken place, i.e., sample metering, chemical reaction, or analytical measurement. Closing previously open valves and channels imparts stringent fluidic control—preventing backflow, maintaining pressurized chambers within the microdevice, and facilitating sample fractionation without cross-contamination. As such, a variety of microfluidic bioanalytical systems would benefit from the integration of these valving approaches.

21 July 2019 in Micromachines
Verified
Journal Article
Open access
PDF file
CCCharles Clark
Charles Clark
VFVahid Farmehini
Vahid Farmehini
LSLiam Spiers
Liam Spiers
MWM. Shane Woolf
M. Shane Woolf
NSNathan Swami
Nathan Swami
James P. LandersJames P. Landers
James P. Landers
Acoustic differential extraction has been previously reported as a viable alternative to the repetitive manual pipetting and centrifugation steps for isolating sperm cells from female epithelial cells in sexual assault sample evidence. However, the efficiency of sperm cell isolation can be compromised in samples containing an extremely large number of epithelial cells. When highly concentrated samples are lysed, changes to the physicochemical nature of the medium surrounding the cells impacts the acoustic frequency needed for optimal trapping. Previous work has demonstrated successful, automated adjustment of acoustic frequency to account for changes in temperature and buffer properties in various samples. Here we show that, during acoustic trapping, real-time monitoring of voltage measurements across the piezoelectric transducer correlates with sample-dependent changes in the medium. This is achieved with a wideband peak detector circuit, which identifies the resonant frequency with minimal disruption to the applied voltage. We further demonstrate that immediate, corresponding adjustments to acoustic trapping frequency provides retention of sperm cells from high epithelial cell-containing mock sexual assault samples.