Xi-Duo Hu

Xi-Duo Hu


Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 July 2019 in Sensors
Verified
Journal Article
Open access
PDF file
YXYongzhao Xu
Yongzhao Xu
XHXi-Duo Hu
Xi-Duo Hu
SKSudip Kundu
Sudip Kundu
Anindya NagAnindya Nag
Anindya Nag
NANasrin Afsarimanesh
Nasrin Afsarimanesh
THTao Han
Tao Han
The paper highlights some of the significant works done in the field of medical and biomedical sensing using silicon-based technology. The use of silicon sensors is one of the pivotal and prolonged techniques employed in a range of healthcare, industrial and environmental applications by virtue of its distinct advantages over other counterparts in Microelectromechanical systems (MEMS) technology. Among them, the sensors for biomedical applications are one of the most significant ones, which not only assist in improving the quality of human life but also help in the field of microfabrication by imparting knowledge about how to develop enhanced multifunctional sensing prototypes. The paper emphasises the use of silicon, in different forms, to fabricate electrodes and substrates for the sensors that are to be used for biomedical sensing. The electrical conductivity and the mechanical flexibility of silicon vary to a large extent depending on its use in developing prototypes. The article also explains some of the bottlenecks that need to be dealt with in the current scenario, along with some possible remedies. Finally, a brief market survey is given to estimate a probable increase in the usage of silicon in developing a variety of biomedical prototypes in the upcoming years.

24 October 2019 in Optics Express
Verified
Journal Article
Closed access
PDF file
ZPZhenrong Pan
Zhenrong Pan
JFJianxun Feng
Jianxun Feng
XHXi-Duo Hu
Xi-Duo Hu
CJChuanyu Jia
Chuanyu Jia
XHXuguang Huang
Xuguang Huang
We propose a novel fiber chemical sensing system based on reflective Mach-Zehnder interference with temperature calibration for the measurement of Cd2+ in aqueous solution. The sensing system has high measurement sensitivity of Cd2+ with an estimated minimum detection limit of 4×10−7 mol/L at a spectral resolution of 0.02 nm and with long-term stability. The fiber sensing head is prepared by coating a sensing membrane on a fused tapering single-mode fiber. The thiourea group of the sensing membrane has an effective combination effect on Cd2+. Disturbance from ambient temperature fluctuation on the measurement of Cd2+ concentration can be eliminated with the fiber Bragg grating.