Hao Chen

Mr. Hao Chen


Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 July 2014 in Energies
Verified
Journal Article
Open access
PDF file
HCHao Chen
Hao Chen
QWQiulan Wan
Qiulan Wan
YWYurong Wang
Yurong Wang
The scientific evaluation methodology for the forecast accuracy of wind power forecasting models is an important issue in the domain of wind power forecasting. However, traditional forecast evaluation criteria, such as Mean Squared Error (MSE) and Mean Absolute Error (MAE), have limitations in application to some degree. In this paper, a modern evaluation criterion, the Diebold-Mariano (DM) test, is introduced. The DM test can discriminate the significant differences of forecasting accuracy between different models based on the scheme of quantitative analysis. Furthermore, the augmented DM test with rolling windows approach is proposed to give a more strict forecasting evaluation. By extending the loss function to an asymmetric structure, the asymmetric DM test is proposed. Case study indicates that the evaluation criteria based on DM test can relieve the influence of random sample disturbance. Moreover, the proposed augmented DM test can provide more evidence when the cost of changing models is expensive, and the proposed asymmetric DM test can add in the asymmetric factor, and provide practical evaluation of wind power forecasting models. It is concluded that the two refined DM tests can provide reference to the comprehensive evaluation for wind power forecasting models.

2 September 2016 in Journal of Modern Power Systems and Clean Energy
Verified
Journal Article
Open access
PDF file
HCHao Chen
Hao Chen
FLFangxing Li
Fangxing Li
YWYurong Wang
Yurong Wang
The impacts of outlying shocks on wind power time series are explored by considering the outlier effect in the volatility of wind power time series. A novel short term wind power forecasting method based on outlier smooth transition autoregressive (OSTAR) structure is advanced, then, combined with the generalized autoregressive conditional heteroskedasticity (GARCH) model, the OSTAR-GARCH model is proposed for wind power forecasting. The proposed model is further generalized to be with fat-tail distribution. Consequently, the mechanisms of regimes against different magnitude of shocks are investigated owing to the outlier effect parameters in the proposed models. Furthermore, the outlier effect is depicted by news impact curve (NIC) and a novel proposed regime switching index (RSI). Case studies based on practical data validate the feasibility of the proposed wind power forecasting method. From the forecast performance comparison of the OSTAR-GARCH models, the OSTAR-GARCH model with fat-tail distribution proves to be promising for wind power forecasting.

30 December 2019 in Protection and Control of Modern Power Systems
Verified
Journal Article
Open access
PDF file
HCHao Chen
Hao Chen
JZJianzhong Zhang
Jianzhong Zhang
YTYubo Tao
Yubo Tao
FTFenglei Tan
Fenglei Tan
Wind power forecasting is of great significance to the safety, reliability and stability of power grid. In this study, the GARCH type models are employed to explore the asymmetric features of wind power time series and improved forecasting precision. Benchmark Symmetric Curve (BSC) and Asymmetric Curve Index (ACI) are proposed as new asymmetric volatility analytical tool, and several generalized applications are presented. In the case study, the utility of the GARCH-type models in depicting time-varying volatility of wind power time series is demonstrated with the asymmetry effect, verified by the asymmetric parameter estimation. With benefit of the enhanced News Impact Curve (NIC) analysis, the responses in volatility to the magnitude and the sign of shocks are emphasized. The results are all confirmed to be consistent despite varied model specifications. The case study verifies that the models considering the asymmetric effect of volatility benefit the wind power forecasting performance.

9 October 2023 in Sensors
Verified
Journal Article
Open access
PDF file
YWYongbin Wu
Yongbin Wu
JZJianzhong Zhang
Jianzhong Zhang
ZYZhengxi Yuan
Zhengxi Yuan
HCHao Chen
Hao Chen
In modern power systems or new energy power stations, the medium voltage circuit breakers (MVCBs) are becoming more crucial and the operation reliability of the MVCBs could be greatly improved by online monitoring technology. The purpose of this research is to put forward a fault diagnosis approach based on vibration signal envelope analysis, including offline fault feature training and online fault diagnosis. During offline fault feature training, the envelope of the vibration signal is extracted from the historic operation data of the MVCB, and then the typical fault feature vector M is built by using the wavelet packet-energy spectrum. In the online fault diagnosis process, the fault feature vector T is built based on the extracted envelope of the real-time vibration signal, and the MVCB states are assessed by using the distance between the feature vectors T and M. The proposed method only needs to handle the envelope of the vibration signal, which dramatically reduces the signal bandwidth, and then the cost of the processing hardware and software could be cut down.

14 July 2022 in Protection and Control of Modern Power Systems
Verified
Journal Article
Open access
PDF file
VLVolker Leitloff
Volker Leitloff
HCHao Chen
Hao Chen
DCDehui Chen
Dehui Chen
ABAndrea Bonetti
Andrea Bonetti
LXLei Xu
Lei Xu
CBCarl Byman
Carl Byman
Fully digitalized substations using IEC 61850 process bus are being introduced all over the world. Numerous utilities have featured pilot projects, demonstrators or even industrial scale deployment of these Fully Digital Protection, Automation and Control Systems (FD-PACS). Product standards such as profiles for Instrument Transformers have been developed and published (IEC 61869-6 and IEC 61869-9 by TC 38—Instrument Transformers). This raises the question about the standards for digitally interfaced protection functions. In 2016, IEC TC 95 (Measuring relays and protection equipment) charged a working group to investigate this subject and to elaborate recommendations concerning requirements and testing of protection IED with digital inputs and outputs for protection standards (IEC 60255-1xx series). For protection functions, publisher/subscriber based data streams are supposed to comply with IEC 61850 and IEC 61869 standards. This holds in particular for Sampled Values (SV) representing energising inputs of the protection function, and is also applicable to Generic Object Oriented Substation Event (GOOSE) which can be used for input or output of protection functions. Quality attributes of published data depend on the operational and connection status of the function and the hosting IED. In addition, protection functions have to take into account the information regarding the time synchronisation of the received SV and other parameters. This paper gives an overview of these features and the proposed way to take them into account in the IEC 60255 standard series. It describes the progress of WG 2 and relates it to existing standardization documents.

1 August 2019
Verified
Conference Paper
Closed access
HCHantao Cui
Hantao Cui
FLFangxing Li
Fangxing Li
XFXin Fang
Xin Fang
HCHao Chen
Hao Chen
HWHonggang Wang
Honggang Wang
This paper deals with extended-term energy storage (ES) arbitrage problems to maximize the annual revenue in deregulated power systems with high-penetration wind power. The conventional ES arbitrage model takes the locational marginal prices (LMP) as an input and is unable to account for the impacts of ES operations on system LMPs. This paper proposes a bilevel ES arbitrage model, where the upper level maximizes the ES arbitrage revenue and the lower level simulates the market clearing process considering wind power and ES. The bilevel model is formulated as a mathematical program with equilibrium constraints) and then recast into a mixed-integer linear programming using strong duality theory. Wind power fluctuations are characterized by the GARCH forecast model and the forecast error is modeled by forecast-bin-based Beta distributions. Case studies are performed on a modified PJM 5-bus system and an IEEE 118-bus system with a weekly time horizon over an annual term to show the validity of the proposed bilevel model. The results from the conventional model and the bilevel model are compared under different ES power and energy ratings, and also various load and wind penetration levels.