The inter-turn short-circuit fault (ITSCF) is a common incipient fault for the permanent magnet synchronous machine (PMSM) drive system. In recent years, the high-resolution ITSCF detection method that combines the high frequency (HF) signal injection and zero-sequence voltage measurement has been put forward. However, for the traditional HF signal injection technique, nonnegligible voltage distortion may occur when the injection frequency is close to the PWM carrier-frequency. In addition, the injected voltage varies with the operating conditions of the PMSM. These drawbacks of the traditional HF signal injection technique greatly limit the ITSCF detection performance using HF signal injection. To further improve the ITSCF detection performance, an improved HF injection scheme is proposed in this paper. In the proposed method, the six active voltage vectors are injected into the PMSM in certain orders to realize a rotating voltage injection, and the injection frequency is up to five-sixth of the PWM carrier-frequency. By employing the proposed injection method, the ITSCF detection sensitivity can be much improved. And the ITSCF detection performance is not affected by the operation conditions of the PMSMs. Finally, the simulations and experiments are carried out to verify the proposed method.
In modern power systems or new energy power stations, the medium voltage circuit breakers (MVCBs) are becoming more crucial and the operation reliability of the MVCBs could be greatly improved by online monitoring technology. The purpose of this research is to put forward a fault diagnosis approach based on vibration signal envelope analysis, including offline fault feature training and online fault diagnosis. During offline fault feature training, the envelope of the vibration signal is extracted from the historic operation data of the MVCB, and then the typical fault feature vector M is built by using the wavelet packet-energy spectrum. In the online fault diagnosis process, the fault feature vector T is built based on the extracted envelope of the real-time vibration signal, and the MVCB states are assessed by using the distance between the feature vectors T and M. The proposed method only needs to handle the envelope of the vibration signal, which dramatically reduces the signal bandwidth, and then the cost of the processing hardware and software could be cut down.
Inertia effect and damping capacity, which are the basic characteristics of traditional power systems, are critical to grid frequency stability. However, the inertia and damping characteristics of grid-tied photovoltaic generation systems (GPVGS), which may affect the frequency stability of the grid with high proportional GPVGS, are not yet clear. Therefore, this paper takes the GPVGS based on droop control as the research object. Focusing on the DC voltage control (DVC) timescale dynamics, the mathematical model of the GPVGS is firstly established. Secondly, the electrical torque analysis method is used to analyze the influence law of inertia, damping and synchronization characteristics from the physical mechanism perspective. The research finds that the equivalent inertia, damping and synchronization coefficient of the system are determined by the control parameters, structural parameters and steady-state operating point parameters. Changing the control parameters is the simplest and most flexible way to influence the inertia, damping and synchronization ability of the system. The system inertia is influenced by the DC voltage outer loop proportional coefficient Kp and enhanced with the increase of Kp. The damping characteristic of the system is affected by the droop coefficient Dp and weakened with the increase of Dp. The synchronization effect is only controlled by DC voltage outer loop integral coefficient Ki and enhanced with the increase of Ki. In addition, the system dynamic is also affected by the structural parameters such as line impedance X, DC bus capacitance C, and steady-state operating point parameters such as the AC or DC bus voltage level of the system and steady-state operating power (power angle). Finally, the correctness of the above analysis are verified by the simulation and experimental results.
17 June 2024 in IEEE Transactions on Instrumentation and Measurement
Signal distortions in voltage, current, and speed are caused by inter-turn short-circuit faults (ISF) in permanent magnet synchronous machines (PMSM). At present, researchers mainly select the collected signal according to the experience and it still lacks the theoretical analysis for the signal selection. For this reason, this paper investigates the signal processing for the detection of the ISF in the PMSM. The signals of speed, current and zero sequence voltage are adopted and the fault features of the ISF are acquired. The applicability comparisons of the fault feature for different signals are conducted according to the sensitivity and the signal-to-noise ratio (SNR). Simulations and experiments are done to confirm that the theoretical analysis is correctness. It is found that the 2nd harmonic occurs in the speed signal and q-axis current i q , and the zero-sequence voltage signal adds the fundamental component under the ISF state. From the indexes of SNR and sensitivity, the zero-sequence voltage is the most effective signal for the ISF detection, and the q-axis current i q is better than the speed signal.
Micro-grid has received extensive attention as an effective way to absorb new energy. Compared to large power systems, the micro-grid system consisting of power electronics is relatively weak due to the lack of support for synchronous machines. In this paper, the direct-drive wind turbine (WT) is connected to the low-inertia micro-grid as the research background. Based on the virtual inertia control of the WT, the inertia source and the physical mechanism of the WT connected to the micro-grid system are studied. The inertia characteristics of the rotor of the WT on the electromechanical time-scale, the DC side capacitor on the DC voltage time-scale, and the simulated grid under the droop control are analyzed. The research results show that under the control of the system, the inertia of the system is derived from the WT, DC capacitor, and the micro-grid simulated by droop control converter. The equivalent inertia of each link is determined by the control parameters, steady-state operating point, and structural parameters. The resulting inertia characteristics will have frequency domain characteristics under control. Finally, the correctness of the system inertia analysis conclusion is verified by simulation and experiment.
1 November 2022 in Journal of Renewable and Sustainable Energy
The harshness and uncertainty of the operating environment have caused a large amount of anomaly data to wind farms, so clean and valid operation data are essential for smart wind power operation and maintenance. Therefore, this paper proposes a composite machine learning algorithm based on the horizontal vertical quartile method and extreme learning machine (ELM) to recognize anomaly wind speed-power data in the wind farm. First, the anomaly points of the wind speed-power data are identified from a bilateral relationship of wind speed and power output by using the horizontal and vertical quartile methods. Second, the effects of different quartile methods on the cleaning effect are compared, and the optimal method with a combination of horizontal and vertical quartiles is selected to identify the abnormality of the wind speed-power data in wind farms. Then, the wind speed-power data could be tagged after anomaly identification, and the sample library is setup. After that, the ELM is trained to learn the data features, and it could be applied to anomaly data identification in the future operation of wind farms. Finally, an example is used to verify the effectiveness of the proposed method.